Search results for "Width"

showing 10 items of 690 documents

Toward a New Test of the Relativistic Time Dilation Factor by Laser Spectroscopy of Fast Ions in a Storage Ring

2003

The frequency measurement of Doppler-shifted optical lines of ions circulating in a storage ring at high speed permits a sensitive test of the relativistic Doppler-formula and, hence, the time dilation factor γSR of special relativity. Previous measurements at the storage ring TSR with 7Li+ at v = 0.065c gave a new, improved limit, but were hampered by the large observed linewidth, exceeding the natural width 15-fold. Recently we have identified the broadening to be caused by velocity-changing processes in the storage ring. Saturation spectroscopy has proven to be largely immune against these effects and has yielded linewidths only a few MHz larger than the natural one. This is the major in…

PhysicsNuclear and High Energy PhysicsCondensed Matter PhysicsAtomic and Molecular Physics and OpticsCharged particleIonLaser linewidthTheory of relativityTime dilationPhysical and Theoretical ChemistryAtomic physicsSaturation (chemistry)SpectroscopyStorage ringHyperfine Interactions
researchProduct

2018

Abstract This article presents a pulsed narrowband injection-locked Titanium:Sapphire laser aimed for high-resolution in-jet resonance ionization spectroscopy at the SLOWRI/PALIS at RIKEN. The laser has been integrated into the PALIS laser laboratory enabling it to be utilized with the existing broadband Titanium:Sapphire and dye lasers. The seed efficiency has been evaluated to be close to unity over the master laser wavelength range ∼ 753 to 791 nm, and the slope efficiency, namely the ratio of the pump power to the output power, was determined to be ∼ 30 % at 780 nm. A two-step ionization scheme with 386.4016 nm first step and 286.731 nm second step into an autoionizing state was develop…

PhysicsNuclear and High Energy PhysicsDye laser010308 nuclear & particles physicsSlope efficiencyTi:sapphire laserPhysics::OpticsLaser01 natural scienceslaw.inventionLaser linewidthlawIonization0103 physical sciencesSapphirePhysics::Atomic PhysicsAtomic physics010306 general physicsSpectroscopyInstrumentationNuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment
researchProduct

Improving the Performance of Quasi-Hemispherical CdZnTe Detectors Using Infrared Stimulation

2012

The influence of monochromatic optical stimulation with wavelengths from 400 to 1100 nm on the characteristics of CdZnTe quasi-hemispherical detectors was studied. It was found that illumination with infrared (IR) light with wavelengths of 870-900 nm close to the absorption edge of the CdZnTe significantly improves the performance of the detector at room temperature. Improvement can be achieved with low-intensity IR illumination at 1-300 μW depending on the chosen wavelength of illumination. Higher intensity illumination was observed to lead to the degradation of the detector's spectrometric characteristics. IR radiation was noted to influence the detector's sensitivity, changing the equili…

PhysicsNuclear and High Energy PhysicsInfraredbusiness.industryDetectorWide-bandgap semiconductorlaw.inventionWavelengthFull width at half maximumOpticsNuclear Energy and EngineeringAbsorption edgelawOptoelectronicsElectrical and Electronic EngineeringbusinessDiodeLight-emitting diodeIEEE Transactions on Nuclear Science
researchProduct

Test of special relativity in an ion storage ring

1996

An accurate measurement of the Doppler effect in collinear laser spectroscopy has been performed at the TSR storage ring with electron cooled7Li+ ions atΒ=0.064. This experiment is a sensitive test of theγ=(1−Β2)−1/2 factor(Β=v/c) in the special theory of relativity. The Doppler shifted frequencies of the moving7Li+ ions are compared with calibrated molecular lines at rest. The frequencies at rest for the7Li+ ions are known from independent measurements. The Doppler shifted frequencies in the collinear experiment have been measured with a precision ofδv/v=6×10−9, mainly limited by the signal width of the resonance. A corresponding upper limit of 8×10−7 is deduced for any deviation of the ti…

PhysicsNuclear and High Energy PhysicsIon beambusiness.industryResonanceSignal WidthCondensed Matter PhysicsRelativistic Doppler effectLaserAtomic and Molecular Physics and Opticslaw.inventionsymbols.namesakeOpticslawsymbolsIves–Stilwell experimentPhysical and Theoretical ChemistryAtomic physicsbusinessDoppler effectStorage ringHyperfine Interactions
researchProduct

Measurement of theD*(2010)+natural linewidth and theD*(2010)+−D0mass difference

2013

We measure the mass difference, Δm_0, between the D^*(2010)^+ and the D^0 and the natural linewidth, Γ, of the transition D^*(2010)^+ → D^0π^+. The data were recorded with the BABAR detector at center-of-mass energies at and near the Υ(4S) resonance, and correspond to an integrated luminosity of approximately 477  fb^(-1). The D^0 is reconstructed in the decay modes D^0 → K^-π^+ and D^0 → K^-π^+π^-π^+. For the decay mode D^0 → K^-π^+ we obtain Γ=(83.4±1.7±1.5)  keV and Δm_0=(145425.6±0.6±1.8)  keV, where the quoted errors are statistical and systematic, respectively. For the D^0 → K^-π^+π^-π^+ mode we obtain Γ=(83.2±1.5±2.6)  keV and Δm_0 = (145426.6±0.5±2.0)  keV. The combined measurements…

PhysicsNuclear and High Energy PhysicsMeson010308 nuclear & particles physicsElectron–positron annihilationGeneral Physics and AstronomyResonance01 natural sciencesLuminosityNuclear physicsLaser linewidthYield (chemistry)0103 physical sciences010306 general physicsPhysical Review D
researchProduct

A broad iron line in the Chandra/HETG spectrum of 4U 1705-44

2004

We present preliminary results from a Chandra 30 ks observation of the atoll sourco 4U 1705 44. In particular we concentrate on the study of the iron Kα line, using the HEG spectrometer. The iron Kα line at ~ 6.6 keV is found to be intrinsically broad (FWHM ~ 1.7 keV); its width can be explained by reflection from a cold accretion disk extending down to ~ 17 km from the neutron star center or by Compton broadening in the hotter (~ 3 – 4 keV) corona.

PhysicsNuclear and High Energy PhysicsNeutron starFull width at half maximumSpectrometerAccretion discK-alphaAstronomyAstrophysicsAtomic and Molecular Physics and Optics
researchProduct

Constraints from lepton universality at the z-peak on unified theories

1995

We suggest the use of a universality-breaking observable based on lepton asymmetries as derived from the left-right asymmetry and the $\tau$ polarization at the $Z$ peak, which can efficiently constrain the parameter space of unified theories. The new observable is complementary to the leptonic partial width differences and it depends critically on the chirality of a possible non-universal $Z$-boson coupling to like-flavour leptons. The LEP/SLC potential of probing universality violation is discussed in representative low-energy extensions of the Standard Model (SM) that could be derived by supersymmetric grand unified theories, such as the SM with left-handed and/or right-handed neutral is…

PhysicsNuclear and High Energy PhysicsParticle physicsPartial widthmedia_common.quotation_subjectHigh Energy Physics::PhenomenologySymmetric modelFOS: Physical sciencesFísicaObservableParameter spacePolarization (waves)AsymmetryUniversality (dynamical systems)High Energy Physics - PhenomenologyHigh Energy Physics - Phenomenology (hep-ph)High Energy Physics::ExperimentLeptonmedia_common
researchProduct

Study of the leptonic decays of the Z0 boson

1990

Measurements are presented of the cross section ratios Rℓ = σℓ(e+e-→ℓ+ℓ -)/σhh(e+e-→hadrons) for ℓ = e, μ and τ using data taken from a scan around the Z0. The results are Re = (5.09±0.32±0.18)%, Rμ = (4.96±0.35±0.17)% and Rτ,=(4.72±0.38± 0.29)% where, for the ratio Re, the t-channel contribution has been subtracted. These results are consistent with the hypothesis of lepton universality and test this hypothesis at the energy scale s ∼ 8300 GeV2. The absolute cross sections σℓ(e+e-→ℓ +ℓ-) have also been measured. From the cross sections the leptonic partial widths Γe = (83.2±3.0±2.4) MeV, (ΓeΓμ) 1/2=(84.6±3.0±2.4) MeV and (ΓeΓτ) 1/2=(82.6±3.3±3.2) MeV have been extracted. Assuming lepton un…

PhysicsNuclear and High Energy PhysicsParticle physics[PHYS.HEXP] Physics [physics]/High Energy Physics - Experiment [hep-ex]010308 nuclear & particles physicsElectron–positron annihilationHadronWidth ratio01 natural sciences7. Clean energyNuclear physics0103 physical sciencesPhysique des particules élémentaires[PHYS.HEXP]Physics [physics]/High Energy Physics - Experiment [hep-ex]Neutrino010306 general physicsParticle Physics - ExperimentLeptonBosonPhysics Letters B
researchProduct

Positronium spectroscopy at a LINAC-based slow positron source

1993

The slow positron facility TEPOS at the Giessen electron LINAC (36 MeV, 120 µA) has been used to produce an intense beam of moderated positrons which is magnetically guided over a distance of 9 m. At a transportation energy of 100 eV about 106 slow e+/s could be extracted out of the magnetic field (0.01 T) and have been electrostatically focussed inside a microwave guide. A small fraction of the positrons form positronium in the excited staten=2. The spontaneous emission of Lyman-α photons (λ=243 nm) from the 2P-states is observed by a photomultiplier. Microwave induced fine-structure transitions 23S1©23P2,1,0 have been observed at 8617(2), 13010(3) and 18494(2) MHz by an increase of the Ly…

PhysicsNuclear and High Energy PhysicsPhotomultiplierPhotonCondensed Matter PhysicsAtomic and Molecular Physics and OpticsPositroniumLaser linewidthPositronExcited statePhysics::Accelerator PhysicsSpontaneous emissionPhysical and Theoretical ChemistryAtomic physicsMicrowaveHyperfine Interactions
researchProduct

In-beam tests of scintillating fibre detectors at MAMI and at GSI

2008

The performance of scintillating fibre detectors was studied with electrons at the spectrometer facility of the Mainz microtron MAMI, as well as in a C-12 beam of 2 AGeV energy and in a beam of different particle species at GSI. Multi-anode photomultipliers were used to read out one or more bundles of 128 fibres each in different geometries. For electrons a time resolution of FWHM = 1 ns was measured in a single detector plane with a detection efficiency epsilon > 99%. A time resolution of 310 ps (FWHM) between two planes of fibres was achieved for carbon ions, leading to a FWHM = 220 ps for a single detector. The hit position residual was measured with a width of FWHM = 0.27 mm. The var…

PhysicsNuclear and High Energy PhysicsPhotomultiplierSpectrometerbusiness.industryDetectorFOS: Physical sciencesCharged particleParticle detectorNuclear physicsFull width at half maximumOpticsNuclear Experiment (nucl-ex)businessInstrumentationMicrotronNuclear ExperimentBeam (structure)
researchProduct