Search results for "Wire"
showing 10 items of 1383 documents
Plaque levels of patients with fixed orthodontic appliances measured by digital plaque image analysis
2011
Introduction A digital plaque image analysis system was developed to objectively assess dental plaque formation and coverage in patients treated with fixed orthodontic appliances. Methods The technique was used to assess plaque levels of 52 patients undergoing treatment with fixed appliances in the Department of Orthodontics at Johannes Gutenberg University in Mainz, Germany. Results Plaque levels ranged from 5.1% to 85.3% of the analyzed tooth areas. About 37% of the patients had plaque levels over 50% of the dentition, but only 10% exhibited plaque levels below 15% of tooth coverage. The mean plaque coverage was 41.9% ± 18.8%. Plaque was mostly present along the gum line and around the or…
New intramedullary locking nail for olecranon fracture fixation--an in vitro biomechanical comparison with tension band wiring.
2010
The aim of this study was to determine the difference in displacement of a newly designed intramedullary olecranon fracture fixation device compared with multifilament tension band wiring after 4 cycles and 300 cycles of dynamic continuous loading.In eight pairs of fresh-frozen cadaver ulnae, oblique olecranon fractures were created and stabilized using either newly designed intramedullary olecranon nail or multifilament tension band wiring. The specimens were then subjected to continuous dynamic loading (from 25 N to 200 N) using matched pairs of cadaveric upper extremities. The Wilcoxon test was used to determine statistical differences of the displacement in the fracture gap.After 4 cycl…
Complications in Craniovertebral Junction Instrumentation: Hardware Removal Can Be Associated with Long-Lasting Stability. Personal Experience
2017
Background The causes of craniovertebral junction (CVJ) instabilities include trauma, rheumatological diseases, tumors, infections, congenital malformations, and degenerative disease processes; these complex pathologies often require CVJ instrumentation. Hardware complications were analyzed in a personal series of 48 treated patients. In light of the analysis of very unusual radiological and clinical findings, the authors tried to better investigate the related mechanisms and to reach possible useful conclusions. Methods In a series of 48 patients who underwent CVJ instrumentation and fusion procedures in our Institution, we describe three cases of hardware failure, due to: (1) infection; (…
Orthodontic load on short maxillary implants with reduced sink depth: an experimental study.
2008
Objective The aim of this study was to investigate experimentally the positional stability and histomorphometric findings of length-reduced temporary anchorage devices (Orthosystem, length: 4 mm) with reduced sink depth. Material and methods For this purpose, four maxillary pre-molars ((2)P(2), (3)P(3)) were extracted from each of four foxhounds. After a 16-week alveolar healing period, 16 implants (four per dog) were inserted into the edentulous areas. Four implants (one per dog) were placed simultaneously in the mid-palatal area. The implants were intentionally submerged to about three-quarters of their length. After a 10-week unloaded implant healing period, the implants in the P3 areas …
Personal exposure to radio-frequency electromagnetic fields in Europe: Is there a generation gap?
2018
Background: Exposure to radiofrequency electromagnetic fields (RF-EMF) from mobile communication technologies is changing rapidly. To characterize sources and associated variability, we studied the differences and correlations in exposure patterns between children aged 8 to 18 and their parents, over the course of the day, by age, by activity pattern, and for different metrics of exposure. Methods: Using portable RF-EMF measurement devices, we collected simultaneous real-time personal measurements of RF-EMF over 24 to 72 h in 294 parent-child pairs from Denmark, the Netherlands, Slovenia, Switzerland, and Spain. The devices measured the power flux density (mW/m(2)) in 16 different frequency…
MMP-2, MMP-9, and iNOS Expression in Human Dental Pulp Subjected to Orthodontic Traction
2009
Abstract Objective: To test the hypothesis that some metalloproteinases (MMP-2, MMP-9) and inducible nitric oxide synthetase (iNOS) enzymes in dental pulp samples do not vary when subjected to orthodontic treatment. Materials and Methods: Human dental pulps were taken from male and female patients (N=10; age 10–14 years). A straight wire technique was used with nickel-titanium or steel archwires. The increase of pressure applied on teeth was gradual. Five patients were subjected to premolar extractions after 14 months of treatment and one after 24 months. Samples were Bouin-fixed, paraffin-embedded, and afterwards processed for immunohistochemistry using anti-MMP-2, anti-MMP-9, and anti-iNO…
Toxicity of used orthodontic archwires assessed by three-dimensional cell culture
2006
The aim of the present study was to determine whether used orthodontic wires made of different materials cause toxicity and loss of viability on three-dimensional (3D) cell cultures. Three types of orthodontic wires, stainless steel, Nitinol, and TMA (n = 9) which had been used clinically in fixed appliances for a period of 1 month, were retrieved at random from five patients. Both upper and lower archwires were collected and subjected to two different protocols: to assess toxicity, two pieces of each wire were placed on 3D cell cultures (reconstituted human epithelium); to investigate the possibility of cell damage, the 3-(4,5-dimethylthiazol-2-yl)2,5-diphenyl tetrazolium bromide (MTT) ass…
A wire-loop technique for implantation of an iliac branched device in a patient with previous surgery for a ruptured abdominal aortic aneurysm
2013
We described a modified technique for implanting a bridging stent-graft into an iliac branched device. A 79-year-old male who had received aortobiiliac synthetic graft surgery for a ruptured abdominal aortic aneurysm six months earlier was admitted to our unit for treatment of a left common iliac aneurysm involving the origin of the hypogastric artery. A standard technique was unsuccessful at implanting the bridging stent-graft, and therefore a wire-loop guidewire over the graft bifurcation was used to stabilize the contralateral sheaths and to complete the implantation. © Turkish Society of Radiology 2012.
Demand for and Pricing of Mobile Internet: Evidence from a Real-World Pricing Experiment
2006
Commercialization of innovations frequently stumbles. A prominent recent example are the early (i.e. pre3G)mobile phone-enabled Internet services, whose European takeup was slower than expected. To determine why, we build a structural model of demand for such services and estimate it using consumerlevel panel data from a real world pricing experiment. The experiment allows for a decomposition of the number of wireless connections into the number of needs instances where a consumer would establish a connection if the price were zero and the conditional probability of establishing a connection. We find that needs were plenty and potential consumer surplus several magnitudes higher than that a…
Closing the sensing-reasoning-actuating loop in resource-constrained WSANs through distributed symbolic processing
2015
Many issues in creating complex applications for pervasive environments are primarily due to the effort required to integrate perception, reasoning and actuating tasks in an efficient and homogeneous way, especially when the underlying infrastructure consists of wirelessly networked embedded devices. To mitigate the complexity of the actual implementation, satisfactory programming paradigms supporting the integration and coordination among heterogeneous devices are required. In this paper we show how a distributed symbolic processing approach that is particularly suited for resource constrained devices, such as the nodes of a Wireless Sensor and Actuator Network (WSAN), may be apt to the pu…