Search results for "Witch"
showing 10 items of 542 documents
Marginal soft tissue stability around conical abutments inserted with the one abutment-one time protocol after 5 years of prosthetic loading
2018
BACKGROUND Soft tissue stability is crucial to obtain and maintain optimal esthetic results. PURPOSE This study aimed to investigate, over 5 years, the soft tissue response using a conical abutment together with the "one-abutment one-time" (OA-OT) protocol in the restoration of implants inserted in the anterior esthetic area. MATERIAL AND METHODS From January 2011 to January 2012, all consecutive patients requiring an implant n the maxillary area between canines were enrolled. After submerged healing and osseointegration, a definitive abutment with a provisional crown was inserted. After 1 month, the definitive crown was delivered (Tdef). Analog impressions were taken before tooth extractio…
Mechanical characteristics and fiber composition of human leg extensor muscles.
1979
To investigate the influence of skeletal muscle fiber composition on the mechanical performance of human skeletal muscle under dynamic conditions, 34 physical education students with differing muscle fiber composition (M. vastus lateralis) were used as subjects to perform maximal vertical jumps on the force-platform. Two kinds of jumps were performed: one from a static starting position (SJ), the other with a preliminary counter-movement (CMJ). The calculated mechanical parameters included height of rise of center of gravity (h), average force (F), net impulse (NI) and average mechanical power (W). It was observed that the percentage of fast twitch fibers was significantly related (p less t…
Neuromuscular responses to different resistance loading protocols using pneumatic and weight stack devices
2013
The purpose of this study was to examine single repetition characteristics and acute neuromuscular responses to typical hypertrophic (HL), maximal strength (MSL), and power (PL) loadings performed with two of the most common resistance modes; pneumatic and weight stack. Acute responses were assessed by measuring maximal voluntary contraction (MVC), corresponding quadriceps-EMG and resting and superimposed twitch torques. Activation level was calculated from the twitch torques. Decreases in MVC were greater during HL and MSL than during PL. During HL, resting twitch force decreased 8% (P < 0.05) more on the weight stack than on the pneumatic device. Furthermore, loading using the weight stac…
Intrathecal somatic hypermutation of IgM in multiple sclerosis and neuroinflammation
2014
Intrathecal oligoclonal bands of the cerebrospinal fluid are considered the most important immunological biomarkers of multiple sclerosis. They typically consist of clonally expanded IgG antibodies that underwent affinity maturation during sustained stimulation by largely unknown antigens. In addition, ∼40% of patients with multiple sclerosis have oligoclonal bands that consist of expanded IgM antibodies. We investigated the molecular composition of IgM- and IgG-chains from cerebrospinal fluid of 12 patients with multiple sclerosis, seven patients with other neurological diseases, and eight healthy control subjects by high-throughput deep-sequencing and single-cell PCR. Further, we studied …
Bilateral and Unilateral Neuromuscular Function and Muscle Cross-Sectional Area in Middle-Aged and Elderly Men and Women
1996
Forty-eight healthy men (M) and women (W), divided into two different age groups, i.e., M50 yrs (range 44-57; n = 12), W50 yrs (range 43-57; n = 12), M70 yrs (range 59-75; n = 12), and W70 yrs (range 62-75; n = 12), volunteered as subjects for examination of muscle cross-sectional area (CSA), maximal voluntary forces, force-time curves, and electromyographic activity of the knee extensor muscles during bilateral and unilateral isometric contractions. The maximal bilateral knee extension force and the average CSA values in M50 were greater (p < .05) than in M70 and in W50 were greater (p < .05-.001) than those recorded for W70. The early forces in the force-time curve were greater (p < .05) …
Dual-Energy CT Material Density Iodine Quantification for Distinguishing Vascular From Nonvascular Renal Lesions: Normalization Reduces Intermanufact…
2019
OBJECTIVE. The purpose of this study was to determine whether a single, uniform normalized iodine threshold reduces variability and enables reliable differentiation between vascular and nonvascular renal lesions independent of the dual-energy CT (DECT) platform used. MATERIALS AND METHODS. In this retrospective, HIPAA-compliant, institutional review board-approved study, 247 patients (156 men, 91 women; mean age ± SD, 67 ± 12 years old) with 263 renal lesions (193 nonvascular, 70 vascular) underwent unenhanced single- energy and contrast-enhanced DECT scans. One hundred and six nonvascular and 38 vascular lesions were scanned on two dual-source DECT (dsDECT) scanners, and 87 nonvascular and…
Frequency, indications, outcomes, and predictive factors of opioid switching in an acute palliative care unit.
2007
The aim of this study was to prospectively evaluate the frequency, indications, outcomes, and predictive factors associated with opioid switching, using a protocol that had been clinically applied and viewed as effective for many years. A prospective study was carried out on a cohort of consecutive cancer patients who were receiving opioids but had an unacceptable balance between analgesia and adverse effects, despite symptomatic treatment of side effects. The initial conversion ratio between opioids and routes was as follows (mg/day): oral morphine 100=intravenous morphine 33=transdermal fentanyl 1=intravenous fentanyl 1=oral methadone 20=intravenous methadone 16=oral oxycodone 70=transder…
Measuring Task-Switching Ability in the Implicit Association Test
2005
Abstract. Recently, the role of method-specific variance in the Implicit Association Test (IAT) was examined ( McFarland & Crouch, 2002 ; Mierke & Klauer, 2003 ). This article presents a new content-unspecific control task for the assessment of task-switching ability within the IAT methodology. Study 1 showed that this task exhibited good internal consistency and stability. Studies 2-4 examined method-specific variance in the IAT and showed that the control task is significantly associated with conventionally scored IAT effects of the IAT-Anxiety. Using the D measures proposed by Greenwald, Nosek, and Banaji (2003 ), the amount of method-specific variance in the IAT-Anxiety could b…
Activation of human quadriceps femoris during isometric, concentric, and eccentric contractions.
2001
Maximal and submaximal activation level of the right knee-extensor muscle group were studied during isometric and slow isokinetic muscular contractions in eight male subjects. The activation level was quantified by means of the twitch interpolation technique. A single electrical impulse was delivered, whatever the contraction mode, on the femoral nerve at a constant 50° knee flexion (0° = full extension). Concentric, eccentric (both at 20°/s velocity), and isometric voluntary activation levels were then calculated. The mean activation levels during maximal eccentric and maximal concentric contractions were 88.3 and 89.7%, respectively, and were significantly lower ( P < 0.05) with respe…
Aging, muscle fiber type, and contractile function in sprint-trained athletes
2006
Biopsy samples were taken from the vastus lateralis of 18- to 84-yr-old male sprinters ( n = 91). Fiber-type distribution, cross-sectional area, and myosin heavy chain (MHC) isoform content were identified using ATPase histochemistry and SDS-PAGE. Specific tension and maximum shortening velocity ( Vo) were determined in 144 single skinned fibers from younger (18–33 yr, n = 8) and older (53–77 yr, n = 9) runners. Force-time characteristics of the knee extensors were determined by using isometric contraction. The cross-sectional area of type I fibers was unchanged with age, whereas that of type II fibers was reduced ( P < 0.001). With age there was an increased MHC I ( P < 0.01) and re…