Search results for "X-Ray"

showing 10 items of 4234 documents

Synthesis and fluorescence emission of neutral and anionic di- and tetra-carboranyl compounds

2011

A new family of photoluminescent neutral and anionic di-carboranyl and tetra-carboranyl derivatives have been synthesized and characterized. The reaction of α,α'-bis(3,5-bis(bromomethyl)phenoxy-m-xylene with 4 equiv. of the monolithium salt of 1-Ph-1,2-C(2)B(10)H(11) or 1-Me-1,2-C(2)B(10)H(11) gives the neutral tetracarboranyl-functionalized aryl ether derivatives closo-1 and closo-2, respectively. The addition of the monolithium salt of 1-Ph-1,2-closo-C(2)B(10)H(11) to α,α,'-dibromo-m-xylene or 2,6-dibromomethyl-pyridine gives the corresponding di-carboranyl derivatives closo-3 and closo-4. These compounds, which contain four or two closo clusters, were degraded using the classical method,…

Boron CompoundsModels MolecularMagnetic Resonance SpectroscopySubstituentSalt (chemistry)Ether010402 general chemistryPhotochemistryCrystallography X-Ray01 natural sciencesInorganic Chemistrychemistry.chemical_compoundPolymer chemistryPyridineMoleculeta116Tetramethylammoniumchemistry.chemical_classificationLuminescent Agents010405 organic chemistry[CHIM.ORGA]Chemical Sciences/Organic chemistryAryl[CHIM.MATE]Chemical Sciences/Material chemistry0104 chemical sciencesSpectrometry FluorescencechemistryCarborane
researchProduct

The influence of fluorine position on the properties of fluorobenzoxaboroles

2015

5-Fluoro-2,1-benzoxaborol-1(3H)-ol, a potent antifungal drug also known as Tavaborole or AN2690, has been compared with its three isomers in terms of its activity against several fungi as well as pKa and multinuclear NMR characterization. The molecular and crystal structure of 6-fluoro-2,1-benzoxaborol-1(3H)-ol was determined and compared with that of AN2690.

Boron CompoundsModels Molecularcrystal structureAntifungal AgentsMagnetic Resonance SpectroscopyHalogenationStereochemistryAntifungal drugchemistry.chemical_elementCrystal structureCrystallography X-RayBiochemistrybenzoxaborolesIsomerismDrug DiscoveryHumansMolecular BiologytavaboroleTavaboroleChemistryOrganic Chemistryantifungal activityFungiFluorineBridged Bicyclo Compounds HeterocyclicMycosesFluorineBioorganic Chemistry
researchProduct

Invitation to participate in a multi-center study for validation of cerebral computed tomography angiography and computed tomography perfusion in the…

2021

In recent years commensal microorganisms are not just “passive occupants”, but important element of homeostasis. There are numerous reports documenting the composition and role of the gut, skin or vagina microbiome but the role of commensal organisms living in the lungs is relatively unknown. Pulmonary microbiome impact on the immune response of the host organism and may indicate new therapeutic directions. Lung microbiome, by modulating the expression of innate immunity genes, causes an increase in the concentration of IL-5, IL-10, IFNγ and CCL11, affects the TLR4 dependent response of pulmonary macrophages and modulate the production of antibacterial peptides contained in the mucus. It is…

Brain Deathmedicine.medical_specialtyComputed tomography perfusionComputed Tomography AngiographyCerebral arteriesCritical Care and Intensive Care MedicineAnesthesiologyicumedicineHumansRD78.3-87.3ChildComputed tomography angiographymedicine.diagnostic_testRC86-88.9business.industryMedical emergencies. Critical care. Intensive care. First aidGeneral MedicineTime optimalUltrasonography dopplerHeart ArrestPerfusionlung microbiomAnesthesiology and Pain MedicineMulti center studyCirculatory systemlung-gut interactionRadiologyTomography X-Ray ComputedbusinessPaediatric population
researchProduct

Target point calculation in the computerized tomography. Comparison of different stereotactic methods

1995

The adaptation of computerized tomography for stereotactic operations requires the transformation of the coordinates of the target point from the CT image space into the stereotactic frame space. Two basic solutions for this transformation are realized in the most of the contemporary stereotactical systems. The indirect geometric method adjusts the frame coordinate system mechanically and identifies its origin in the CT image. There are 6 degrees of freedom: 3 of rotation and 3 of translation which have to be taken into consideration. The second method is a based on direct algebraic coordinate transformation and is independent of the explicite knowledge of the relationship between the image…

Brain Diseasesbusiness.industryCoordinate systemFrame (networking)General MedicineTranslation (geometry)Stereotaxic TechniquesTransformation matrixTransformation (function)Position (vector)HumansMedicineSurgeryPoint (geometry)Computer visionNeurology (clinical)Artificial intelligenceTomography X-Ray ComputedbusinessMathematical ComputingRotation (mathematics)Neurosurgical Review
researchProduct

Flat Panel Computed Tomography Pooled Blood Volume and Infarct Prediction in Endovascular Stroke Treatment

2019

Background and Purpose— Patients with large-vessel stroke frequently need to be transferred to comprehensive stroke centers for endovascular treatment. An update of physiological perfusion parameters and stroke progression on arrival is desirable. We examined the reliability of preinterventional pooled blood volume (PBV)-maps acquired by flat-panel detector computed tomography (CT) in the interventional angiography suite. Methods— The volumes of preinterventional perfusion deficit in flat-panel detector CT-PBV source images were compared with final infarct volume on follow-up multislice-CT after endovascular treatment of 29 consecutive patients with occlusion of the middle cerebral artery …

Brain InfarctionMaleMechanical Thrombolysismedicine.medical_treatmentBlood volume030204 cardiovascular system & hematology03 medical and health sciencesPostoperative Complications0302 clinical medicinePredictive Value of Testsmedicine.arteryOcclusionmedicineCerebral Blood VolumeHumanscardiovascular diseasesStrokeAgedAdvanced and Specialized Nursingmedicine.diagnostic_testbusiness.industryCerebral infarctionEndovascular ProceduresThrombolysisMiddle Agedmedicine.diseaseCerebral AngiographyStrokeMiddle cerebral arteryAngiographyFemaleNeurology (clinical)Internal carotid arteryTomography X-Ray ComputedCardiology and Cardiovascular MedicinebusinessNuclear medicine030217 neurology & neurosurgeryFollow-Up StudiesStroke
researchProduct

Forensic investigation of brick stones using instrumental neutron activation analysis (INAA), laser ablation-inductively coupled plasma-mass spectrom…

2009

Abstract Brick stones collected from different production facilities were studied for their elemental compositions under forensic aspects using laser ablation–inductively coupled plasma–mass spectrometry (LA–ICP–MS), instrumental neutron activation analysis (INAA) and X-ray fluorescence analysis (XRF). The aim of these examinations was to assess the potential of these methods in forensic comparison analyses of brick stones. The accuracy of the analysis methods was evaluated using NIST standard reference materials (679, 98b and 97b). In order to compare the stones to each other, multivariate data analysis was used. The evaluation of the INAA results (based on the concentrations of V, Na, K, …

BrickRadiationLa icp msChemistryElemental analysisLaser ablation inductively coupled plasma mass spectrometryAnalytical chemistryX-ray fluorescenceNeutron activation analysisMass spectrometryAnalysis methodApplied radiation and isotopes : including data, instrumentation and methods for use in agriculture, industry and medicine
researchProduct

Long-term optical and X-ray variability of the Be/X-ray binary H 1145-619: Discovery of an ongoing retrograde density wave

2017

Multiwavelength monitoring of Be/X-ray binaries is crucial to understand the mechanisms producing their outbursts. H 1145-619 is one of these systems, which has recently displayed X-ray activity. We investigate the correlation between the optical emission and the X-ray activity to predict the occurrence of new X-ray outbursts from the inferred state of the circumstellar disc. We have performed a multiwavelength study of H 1145-619 from 1973 to 2017 and present here a global analysis of its variability over the last 40 years. We have used optical spectra from the SAAO, SMARTS and SALT telescopes and optical photometry from INTEGRAL/OMC and ASAS. We also used X-ray observations from INTEGRAL/…

BrightnessBe starAstrophysics::High Energy Astrophysical Phenomenamedia_common.quotation_subjectX-ray binarystars: emission-lineFOS: Physical sciencesAstrophysics01 natural sciencesSpectral lineDensity wave theoryPhotometry (optics)X-rays: binariesstars: neutrontechniques: photometric0103 physical sciencesAstrophysics::Solar and Stellar Astrophysics010303 astronomy & astrophysicsSolar and Stellar Astrophysics (astro-ph.SR)Astrophysics::Galaxy Astrophysicsmedia_commonHigh Energy Astrophysical Phenomena (astro-ph.HE)Physics010308 nuclear & particles physicsBeAstronomy and AstrophysicsLight curvestars: emission-line BeAstrophysics - Solar and Stellar Astrophysics13. Climate actionSpace and Planetary ScienceSkyAstrophysics::Earth and Planetary AstrophysicsAstrophysics - High Energy Astrophysical Phenomenatechniques: spectroscopicAstronomy & Astrophysics
researchProduct

Revealing the structure of the lensed quasar Q 0957+561. I. Accretion disk size

2021

We thank the anonymous referee for the helpful comments, and constructive remarks on this manuscript. We thank the GLENDAMA project for making publicly available the monitoring data of Q 0957+561. C.F. gratefully acknowledges the financial support from Tel Aviv University and University of Haifa through a DFG grant HA3555-14/1. E.M. and J.A.M are supported by the Spanish MINECO with the grants AYA2016- 79104-C3-1-P and AYA2016-79104-C3-3-P. J.A.M. is also supported from the Generalitat Valenciana project of excellence Prometeo/2020/085. J.J.V. is supported by the project AYA2017-84897-P financed by the Spanish Ministerio de Economia y Competividad and by the Fondo Europeo de Desarrollo Regi…

Brightnessmagnificationtime-delayFOS: Physical sciencesAstrophysicsgravitational lensing: microAstrophysics::Cosmology and Extragalactic AstrophysicsGravitational microlensingvlbi observationsmicro [Gravitational lensing]accretionpeculiar velocityindividual: Q 0957+561 [Quasars]Astrophysics::Galaxy AstrophysicsPhysicsquasars: individual: q 0957+561robust determinationaccretion disksvelocity dispersionq0957+561Astronomy and AstrophysicsQuasarAccretion accretion disksLight curveAstrophysics - Astrophysics of GalaxiesGalaxyAccretion (astrophysics)StarsGravitational lensdark-matterx-raySpace and Planetary ScienceAstrophysics of Galaxies (astro-ph.GA)Astrophysics::Earth and Planetary Astrophysicsoptical continuum emission
researchProduct

XAFS Studies of High-Valent Porphyrinato Manganèse Complexes with Ozone

1997

We produce strong evidence of the interaction of ozone with a series of Manganese (III) porphyrinato complexes to form a well defined reactive intermediate. In the latter species, the Manganese atom which is formally in a tetravalent (IV) state, is (at least) hexacoordinated with the metal unambiguously lying in the basal plane of the four pyrrolic nitrogens of the porphyrin macrocycle. Substitution of Bromine or Chlorine axial ligands by ozonids is most likely to happen. This conclusion is also supported by XANES and EXAFS spectra recorded at the Chlorine K-edge which suggest that ozone may even form with chlorine a complex anion.

BromineExtended X-ray absorption fine structureReactive intermediateInorganic chemistryGeneral Physics and Astronomychemistry.chemical_elementManganesePorphyrinX-ray absorption fine structureMetalchemistry.chemical_compoundchemistryvisual_artpolycyclic compoundsChlorinevisual_art.visual_art_mediumLe Journal de Physique IV
researchProduct

Analysis of Sagunto Ibero-Roman votive bronze statuettes by portable X-ray fluorescence

2019

Abstract The main objective of this work was the study of chemical composition of an important collection of Ibero-Roman votive bronze statuettes exposed in the Archaeological Museum of Sagunto (Spain). Precision and accuracy of the measurements were obtained developing a proper analytical method, also avoiding any possible damage to the studied objects using a portable energy dispersive X- ray fluorescence system. Principal Components Analysis (PCA) to discriminate between groups based on ratios Fe/Cu, Pb/Cu, Sn/Cu, Ag/Cu, Ni/Cu and Impurities/Cu were employed to observe differences between the used smelting, manufacturing processes and raw materials. The characterisation of bronze statuet…

Bronze statuettesRadiationMaterials sciencepXRFMetallurgyortable energy dispersive X- ray fluorescence systemMetals provenanceengineering.materialpXRF; Bronze statuettes; Ibero-Roman; Sagunto; Metals provenanceIbero-RomanSmeltingengineeringPortable X-raySaguntoBronzeRadiation Physics and Chemistry
researchProduct