Search results for "X-ray Spectroscopy"
showing 10 items of 93 documents
High‐Resolution X‐Ray Spectroscopy of the Post–T Tauri Star PZ Telescopii
2004
We present an analysis of the Chandra High Energy Transmission Grating Spectrometer observation of the rapidly rotating P_(rot)=0.94 d post T Tauri (~20 Myr old) star PZ Telescopii, in the Tucana association. Using two different methods we have derived the coronal emission measure distribution, em(T), and chemical abundances. The em(T) peaks at log T = 6.9 and exhibits a significant emission measure at temperatures log T > 7. The coronal abundances are generally ~0.5 times the solar photospheric values that are presumed fairly representative of the composition of the underlying star. A minimum in abundance is seen at a first ionization potential (FIP) of 7-8 eV, with evidence for higher abu…
An Active X-Ray Spectrometer for the SELENE-2 Rover
2014
The Active X-ray Spectrometer (AXS) for the Japanese SELENE-2 rover has been proposed for elemental analysis on the lunar surface to measure the major elements: Mg, Al, Si, Ca, Ti, and Fe; the minor elements, Na, K, P, S, Cl, Cr, and Mn and the trace element Ni, all depending on their concentrations at a landing site. The elemental data of the AXS allow us to not only classification but also quantification of surface rocks on the Moon. The AXS is a compact low-weight instrument for elemental analysis based on the principle of X-ray fluorescence spectrometry using an X-ray spectrometer and two (four) pyroelectric crystals as X-Ray Generators (XRG). This paper introduces the current status of…
High Energy, High Resolution X-Ray Spectroscopy: Microcalorimeters For Nuclear Line Astrophysics
2005
We introduce focusing optics and microcalorimeter spectroscopy to nuclear line emission astrophysics with a balloon payload concept called, B‐MINE. It is designed to probe the deepest regions of a supernova explosion by detecting 44Ti emission at 68 keV with spatial and spectral resolutions that are sufficient to determine the velocity distribution of the 44Ti emitting region. B‐MINE has a thin plastic foil telescope multilayered to maximize the reflectivity in a 20 keV band centered at 68 keV and a microcalorimeter array optimized for the same energy band. This combination provides a reduced background, an energy resolution of 50 eV and a 3σ sensitivity in 106 s of 6 × 10−8 ph cm−2 s−1 at …
Characterization of Al-Schottky CdTe detectors
2011
In the last decades, great efforts are being devoted to the development of CdTe detectors for high resolution X-ray and gamma ray spectroscopy. Recently, new rectifying contacts based on aluminum (Al) are very appealing in the development of CdTe detectors with low leakage currents and anode pixellization. In this work, we report on preliminary results of electrical and spectroscopic investigations on Schottky CdTe diode detectors (4.1 × 4.1 × 0.75 and 4.1 × 4.1 × 2 mm3) with Au/Ti/Al/CdTe/Pt electrode configuration. The detectors are characterized by very low leakage currents even at room temperature (26 pA at 25 °C under a bias voltage of −100 V for the 2 mm thick detector). Polarization …
The ATHENA X-ray Integral Field Unit (X-IFU)
2018
Event: SPIE Astronomical Telescopes + Instrumentation, 2018, Austin, Texas, United States.
Spontaneous core–shell elemental distribution in In-rich In(x)Ga1-xN nanowires grown by molecular beam epitaxy.
2014
International audience; The elemental distribution of self-organized In-rich InxGa1-xN nanowires grown by plasma-assisted molecular beam epitaxy has been investigated using three different techniques with spatial resolution on the nanoscale. Two-dimensional images and elemental profiles of single nanowires obtained by x-ray fluorescence and energy-dispersive x-ray spectroscopy, respectively, have revealed a radial gradient in the alloy composition of each individual nanowire. The spectral selectivity of resonant Raman scattering has been used to enhance the signal from very small volumes with different elemental composition within single nanowires. The combination of the three techniques ha…
Studies on atomic layer deposition of IRMOF-8 thin films
2015
Deposition of IRMOF-8 thin films by atomic layer deposition was studied at 260–320 C. Zinc acetate and 2,6-naphthalenedicarboxylic acid were used as the precursors. The as-deposited amorphous films were crystallized in 70% relative humidity at room temperature resulting in an unknown phase with a large unit cell. An autoclave with dimethylformamide as the solvent was used to recrystallize the films into IRMOF-8 as confirmed by grazing incidence x-ray diffraction. The films were further characterized by high temperature x-ray diffraction (HTXRD), field emission scanning electron microscopy, Fourier transform infrared spectroscopy (FTIR), time-of-flight elastic recoil detection analysis (TOF-…
Fabrication of Electrical Contacts on Pyramid-Shaped NTD-Ge Microcalorimeters Using Free-Standing Shadow Masks
2011
In our effort to fabricate arrays of germanium microcalorimeters for X-ray detection, a truncated square-based pyramid shape has been identified as a suitable geometry for the sensors. It allows to obtain a uniform current spreading across each sensor, and represents a good compromise between having a large support area for the radiation absorber and for maintaining an overall small bolometer volume. This three-dimensional geometry, however, does not allow to create the electrical contacts for the sensors using a regular photoresist-based lift-off metallization process. In this paper we show how to deposit metal contacts on the lateral faces of the pyramidal sensors by metal evaporation thr…
Synthesis, chemical characterization and biological activity of new histone acetylation/deacetylation specific inhibitors: a novel and potential appr…
2013
Three new triorganotin(IV) complexes of valproic acid (vp1, Me3Sn-valproate; vp2, Bu3Sn-valproate; vp3, Ph3Sn-valproate) have been synthesized and investigated by spectroscopic and biological methods. An anionic, monodentate valproate ligand was observed, ester-like coordinating the tin atom on a tetra-coordinated, monomeric environment. The structures, though, can distort towards a penta-coordination, as a consequence of a long range O center dot center dot center dot Sn interaction. Crystallographic and NMR findings confirm this situation both in solid state and solution. Biological finding evidenced a clear cytotoxic action of the complexes in hepatocellular carcinoma cell cultures: one …
Spectral broadening by spatial effects in X-ray microcalorimeters with superconducting absorber and NTD-Ge thermal sensor
2004
We discuss how the sensitivity to the position of absorption of the photons can affect the spectral resolution of X-ray microcalorimeters with superconducting Sn absorber and NTD-Ge thermal sensor. Data obtained through the computer simulations are reported for microcalorimeters with different geometries and phonon transmission probabilities at the interface between the absorber and thermistor.