Search results for "X-ray Spectroscopy"

showing 10 items of 93 documents

High‐Resolution X‐Ray Spectroscopy of the Post–T Tauri Star PZ Telescopii

2004

We present an analysis of the Chandra High Energy Transmission Grating Spectrometer observation of the rapidly rotating P_(rot)=0.94 d post T Tauri (~20 Myr old) star PZ Telescopii, in the Tucana association. Using two different methods we have derived the coronal emission measure distribution, em(T), and chemical abundances. The em(T) peaks at log T = 6.9 and exhibits a significant emission measure at temperatures log T > 7. The coronal abundances are generally ~0.5 times the solar photospheric values that are presumed fairly representative of the composition of the underlying star. A minimum in abundance is seen at a first ionization potential (FIP) of 7-8 eV, with evidence for higher abu…

PhysicsX-ray spectroscopyHigh resolutionAstronomy and AstrophysicsAstrophysicsElectronCoronaAccretion (astrophysics)StarsT Tauri starSettore FIS/05 - Astronomia E AstrofisicaSpace and Planetary ScienceStars: Abundances Stars: Coronae Stars: Individual: Constellation Name: PZ Telescopii Stars: Pre-Main-Sequence Techniques: Spectroscopic X-Rays: StarsIonization energyThe Astrophysical Journal
researchProduct

An Active X-Ray Spectrometer for the SELENE-2 Rover

2014

The Active X-ray Spectrometer (AXS) for the Japanese SELENE-2 rover has been proposed for elemental analysis on the lunar surface to measure the major elements: Mg, Al, Si, Ca, Ti, and Fe; the minor elements, Na, K, P, S, Cl, Cr, and Mn and the trace element Ni, all depending on their concentrations at a landing site. The elemental data of the AXS allow us to not only classification but also quantification of surface rocks on the Moon. The AXS is a compact low-weight instrument for elemental analysis based on the principle of X-ray fluorescence spectrometry using an X-ray spectrometer and two (four) pyroelectric crystals as X-Ray Generators (XRG). This paper introduces the current status of…

PhysicsX-ray spectroscopySpectrometerElemental analysisAnalytical chemistrySurface roughnessTrace elementFluorescence spectrometryFluxPyroelectricityRemote sensingTRANSACTIONS OF THE JAPAN SOCIETY FOR AERONAUTICAL AND SPACE SCIENCES, AEROSPACE TECHNOLOGY JAPAN
researchProduct

High Energy, High Resolution X-Ray Spectroscopy: Microcalorimeters For Nuclear Line Astrophysics

2005

We introduce focusing optics and microcalorimeter spectroscopy to nuclear line emission astrophysics with a balloon payload concept called, B‐MINE. It is designed to probe the deepest regions of a supernova explosion by detecting 44Ti emission at 68 keV with spatial and spectral resolutions that are sufficient to determine the velocity distribution of the 44Ti emitting region. B‐MINE has a thin plastic foil telescope multilayered to maximize the reflectivity in a 20 keV band centered at 68 keV and a microcalorimeter array optimized for the same energy band. This combination provides a reduced background, an energy resolution of 50 eV and a 3σ sensitivity in 106 s of 6 × 10−8 ph cm−2 s−1 at …

PhysicsX-ray spectroscopySpectrometerPhysics::Instrumentation and Detectorsbusiness.industryAstrophysics::High Energy Astrophysical PhenomenaResolution (electron density)Astrophysicslaw.inventionTelescopeSupernovaOpticslawEmission spectrumSpectroscopybusinessX- and gamma-ray telescopes and instrumentation Photometric polarimetric and spectroscopic instrumentationLine (formation)
researchProduct

Characterization of Al-Schottky CdTe detectors

2011

In the last decades, great efforts are being devoted to the development of CdTe detectors for high resolution X-ray and gamma ray spectroscopy. Recently, new rectifying contacts based on aluminum (Al) are very appealing in the development of CdTe detectors with low leakage currents and anode pixellization. In this work, we report on preliminary results of electrical and spectroscopic investigations on Schottky CdTe diode detectors (4.1 × 4.1 × 0.75 and 4.1 × 4.1 × 2 mm3) with Au/Ti/Al/CdTe/Pt electrode configuration. The detectors are characterized by very low leakage currents even at room temperature (26 pA at 25 °C under a bias voltage of −100 V for the 2 mm thick detector). Polarization …

PhysicsX-ray spectroscopySpectrometerbusiness.industrySettore FIS/01 - Fisica SperimentaleDetectorSchottky diodeBiasingSettore FIS/07 - Fisica Applicata(Beni Culturali Ambientali Biol.e Medicin)AnodeCdTe detectorFull width at half maximumX-ray and gamma ray spectroscopyOpticsOptoelectronicsGamma spectroscopybusiness2011 IEEE Nuclear Science Symposium Conference Record
researchProduct

The ATHENA X-ray Integral Field Unit (X-IFU)

2018

Event: SPIE Astronomical Telescopes + Instrumentation, 2018, Austin, Texas, United States.

Point spread functionPhotonAstrophysics::High Energy Astrophysical PhenomenaField of viewAthena; Instrumentation; Space telescopes; X-ray Integral Field Unit; X-ray spectroscopy; Electronic Optical and Magnetic Materials; Condensed Matter Physics; Computer Science Applications1707 Computer Vision and Pattern Recognition; Applied Mathematics; Electrical and Electronic EngineeringCondensed Matter PhysicLarge format01 natural sciences7. Clean energySpace telescopeslaw.inventionTelescopePhysics::Popular PhysicsSettore FIS/05 - Astronomia E AstrofisicaOpticslawPhysics::Plasma Physics0103 physical sciencesElectronicAthenaOptical and Magnetic MaterialsSpectral resolutionElectrical and Electronic Engineering010306 general physics010303 astronomy & astrophysicsInstrumentationPhysicsSpectrometerbusiness.industryElectronic Optical and Magnetic MaterialApplied MathematicsDetectorAstrophysics::Instrumentation and Methods for AstrophysicsComputer Science Applications1707 Computer Vision and Pattern RecognitionCondensed Matter Physics115 Astronomy Space sciencePhysics::History of PhysicsApplied MathematicSpace telescopeX-ray Integral Field UnitX-ray spectroscopybusiness
researchProduct

Spontaneous core–shell elemental distribution in In-rich In(x)Ga1-xN nanowires grown by molecular beam epitaxy.

2014

International audience; The elemental distribution of self-organized In-rich InxGa1-xN nanowires grown by plasma-assisted molecular beam epitaxy has been investigated using three different techniques with spatial resolution on the nanoscale. Two-dimensional images and elemental profiles of single nanowires obtained by x-ray fluorescence and energy-dispersive x-ray spectroscopy, respectively, have revealed a radial gradient in the alloy composition of each individual nanowire. The spectral selectivity of resonant Raman scattering has been used to enhance the signal from very small volumes with different elemental composition within single nanowires. The combination of the three techniques ha…

Raman scatteringMaterials scienceNanostructureAnalytical chemistryNanowireBioengineering02 engineering and technologyEpitaxy01 natural sciencesMolecular physicssymbols.namesakeCondensed Matter::Materials ScienceEDXalloy0103 physical sciencesGeneral Materials ScienceElectrical and Electronic EngineeringSpectroscopy010302 applied physics[PHYS]Physics [physics]X-ray spectroscopyx-ray fluorescenceMechanical EngineeringHeterojunctionGeneral Chemistry021001 nanoscience & nanotechnologyMechanics of Materialsnanowiresymbols0210 nano-technologyRaman scatteringMolecular beam epitaxyNanotechnology
researchProduct

Studies on atomic layer deposition of IRMOF-8 thin films

2015

Deposition of IRMOF-8 thin films by atomic layer deposition was studied at 260–320 C. Zinc acetate and 2,6-naphthalenedicarboxylic acid were used as the precursors. The as-deposited amorphous films were crystallized in 70% relative humidity at room temperature resulting in an unknown phase with a large unit cell. An autoclave with dimethylformamide as the solvent was used to recrystallize the films into IRMOF-8 as confirmed by grazing incidence x-ray diffraction. The films were further characterized by high temperature x-ray diffraction (HTXRD), field emission scanning electron microscopy, Fourier transform infrared spectroscopy (FTIR), time-of-flight elastic recoil detection analysis (TOF-…

Scanning electron microscopeAnalytical chemistryfield emission microscopesInfrared spectroscopyAtomic layer depositionThin filmFourier transform infrared spectroscopyta116kuormausta114ChemistrySurfaces and InterfacesatomikerroskasvatusCondensed Matter PhysicspalladiumX-ray diffractionSurfaces Coatings and FilmsAmorphous solidfourier transform infrared spectroscopyElastic recoil detectionamorphous filmsloadingCarbon filmthin filmsenergy dispersive spectroscopyatomic layer depositionX-ray spectroscopyohutkalvotzinc compoundsscanning electron microscopyJournal of Vacuum Science and Technology A
researchProduct

Fabrication of Electrical Contacts on Pyramid-Shaped NTD-Ge Microcalorimeters Using Free-Standing Shadow Masks

2011

In our effort to fabricate arrays of germanium microcalorimeters for X-ray detection, a truncated square-based pyramid shape has been identified as a suitable geometry for the sensors. It allows to obtain a uniform current spreading across each sensor, and represents a good compromise between having a large support area for the radiation absorber and for maintaining an overall small bolometer volume. This three-dimensional geometry, however, does not allow to create the electrical contacts for the sensors using a regular photoresist-based lift-off metallization process. In this paper we show how to deposit metal contacts on the lateral faces of the pyramidal sensors by metal evaporation thr…

Shadow maskX-ray detectorShadow evaporationFabricationMaterials scienceMicrocalorimeter arrayNTD-GeX-ray detectorchemistry.chemical_elementGermaniumPhotoresistSettore ING-INF/01 - Elettronicalaw.inventionOpticslawGeneral Materials SciencePyramid (geometry)Free-standing maskbusiness.industryBolometerCondensed Matter PhysicsAtomic and Molecular Physics and OpticsElectrical contactschemistryX-ray spectroscopybusiness
researchProduct

Synthesis, chemical characterization and biological activity of new histone acetylation/deacetylation specific inhibitors: a novel and potential appr…

2013

Three new triorganotin(IV) complexes of valproic acid (vp1, Me3Sn-valproate; vp2, Bu3Sn-valproate; vp3, Ph3Sn-valproate) have been synthesized and investigated by spectroscopic and biological methods. An anionic, monodentate valproate ligand was observed, ester-like coordinating the tin atom on a tetra-coordinated, monomeric environment. The structures, though, can distort towards a penta-coordination, as a consequence of a long range O center dot center dot center dot Sn interaction. Crystallographic and NMR findings confirm this situation both in solid state and solution. Biological finding evidenced a clear cytotoxic action of the complexes in hepatocellular carcinoma cell cultures: one …

StereochemistryCell SurvivalAntineoplastic AgentsBiochemistryInorganic ChemistryHistonesHistone H3Organotin CompoundsCytotoxic T cellHumansViability assayCells CulturedMOSSBAUER SPECTROSCOPYOrganoTin(IV)biologyX-RAY DIFFRACTIONChemistryMössbauer spectroscopyValproic AcidESI-MSBiological activityAcetylationHep G2 CellsLigand (biochemistry)NMRHistoneBiochemistryApoptosisAcetylationSettore CHIM/03 - Chimica Generale E Inorganicabiology.proteinX-ray spectroscopy
researchProduct

Spectral broadening by spatial effects in X-ray microcalorimeters with superconducting absorber and NTD-Ge thermal sensor

2004

We discuss how the sensitivity to the position of absorption of the photons can affect the spectral resolution of X-ray microcalorimeters with superconducting Sn absorber and NTD-Ge thermal sensor. Data obtained through the computer simulations are reported for microcalorimeters with different geometries and phonon transmission probabilities at the interface between the absorber and thermistor.

SuperconductivityPhysicsNuclear and High Energy PhysicsPhotonPhysics::Instrumentation and DetectorsPhononbusiness.industryThermistorX-rayNumerical simulationOpticsMicrocalorimeterX-ray spectroscopySpectral resolutionbusinessAbsorption (electromagnetic radiation)InstrumentationDoppler broadeningNuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment
researchProduct