Search results for "X-ray detector."

showing 10 items of 42 documents

Charge Transport Properties in CZT Detectors Grown by the Vertical Bridgman Technique

2010

Great efforts are being presently devoted to the development of CdTe and CdZnTe detectors for a large variety of applications, such as medical, industrial, and space research. We present the spectroscopic properties of some CZT crystals grown by the standard vertical Bridgman method and by the boron oxide encapsulated vertical Bridgman method, which has been recently implemented at IMEM-CNR (Parma, Italy). By this technique the crystal is grown in an open quartz crucible fully encapsulated by a thin layer of liquid boron oxide. This method prevents contact between the crystal and the crucible thereby allowing larger single grains with a lower dislocation density to be obtained. Several mono…

Materials sciencebusiness.industrySettore FIS/01 - Fisica SperimentaleCrucibleSynchrotron radiationX-ray detectorsCadmium telluride photovoltaicsCrystalBoron oxideElectric fieldElectronic engineeringCdZnTeOptoelectronicsCharge carrierbusinessBeam (structure)CZT detectors
researchProduct

The DEPFET based Focal Plane Detectors for MIXS on BepiColombo

2010

X-ray detectors based on arrays of DEPFET macropixels, which consist of a silicon drift detector combined with a detector/amplifier structure DEPFET as readout node, provide a convenient and flexible way to adapt the pixel size of a focal plane detector to the resolving power of any given X-ray optical system. Macropixels combine the traditional benefits of an SDD, like scalability, arbitrary geometry and excellent QE even in the low energy range, with the advantages of DEPFET structures: Charge storage capability, near Fano-limited energy resolution, low power consumption and high speed readout. Being part of the scientific payload of ESA's BepiColombo mission, the MIXS instrument will be …

PhysicsCMOS sensorMacropixelActive Pixel SensorSilicon drift detectorPhysics::Instrumentation and Detectorsbusiness.industryAmplifierBepiColomboDetectorX-ray detectorHigh voltagePlanetary XRFSettore ING-INF/01 - ElettronicaParticle detectorImagingOpticsCardinal pointIXOMIXSX-RaybusinessIXO; X-Ray; Planetary XRF; DEPFET; Macropixel; Active Pixel Sensor; Imaging; Spectroscopy; MIXS; BepiColomboDEPFETSpectroscopy
researchProduct

DEPFET based Instrumentation for the MIXS focal plane on BepiColombo

2009

BepiColombo, ESA's fifth cornerstone mission, is a planetary exploration mission to Mercury. On board of BepiColombo's Mercury Planetary Orbiter (MPO), the MIXS instrument will perform a complete X-ray fluorescence analysis of Mercury's crust with unprecedented spectral and spatial resolution. This is achieved by using a lightweight X-ray mirror system and by using of DEPFET based Macropixel devices as X-ray detectors. DEPFET based Macropixel detectors combine the advantages of the DEPFETs, like flexible readout modes, Fano-limited energy resolution and low power consumption, with the properties of the drift detectors, like arbitrary scalable pixel size and geometry. In addition, the excell…

PhysicsCMOS sensorPhysics::Instrumentation and Detectorsbusiness.industryAstrophysics::High Energy Astrophysical PhenomenaDetectorX-ray detectorOrbital mechanicsSettore ING-INF/01 - ElettronicaSynchrotronlaw.inventionOrbiterOpticsCardinal pointlawPhysics::Space PhysicsAstrophysics::Earth and Planetary AstrophysicsbusinessImage resolution
researchProduct

The wide field imager for the International X-ray Observatory

2009

The large collecting area of the X-ray optics on the International X-ray Observatory (IXO), their good angular resolution, the wide bandwidth of X-ray energies and the high radiation tolerance required for the X-ray detectors in the focal plane have stimulated a new development of devices which unify all those science driven specifications in one single detector. The concept of a monolithic, back-illuminated silicon active pixel sensor (APS) based on the DEPFET structure is proposed for the IXO mission, being a fully depleted, back-illuminated 450 μm thick detector with a physical size of about 10 × 10 cm 2 corresponding to the 18 arcmin field of view. The backside will be covered with an i…

PhysicsCMOS sensorbusiness.industryDetectorInternational X-ray ObservatoryX-ray detectorX-ray opticsField of viewSettore ING-INF/01 - ElettronicaOpticsObservatoryOptoelectronicsbusinessImage resolutionSPIE Proceedings
researchProduct

NTD-GE-based microcalorimeter performance

2000

Our group has been developing x-ray microcalorimeters consisting of neutron transmutation doped (NTD) germanium thermistors attached to superconducting tin absorbers. We discuss the performance of single pixel x-ray detectors, and describe an array technology. In this paper we describe the read-out circuit that allows us to measure fast signals in our detectors as this will be important in understanding the primary cause of resolution broadening. We describe briefly a multiplexing scheme that allows a number of different calorimeters to be read out using a single JFET. We list the possible causes of broadening and give a description of the experiment which best demonstrates the cause of the…

PhysicsNuclear and High Energy PhysicsNuclear transmutationPhysics::Instrumentation and Detectorsbusiness.industryDetectorX-ray detectorchemistry.chemical_elementJFETGermaniumMultiplexingElectromagnetic interferenceSettore FIS/05 - Astronomia E AstrofisicaOpticschemistryOptoelectronicsNeutronbusinessInstrumentationNuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment
researchProduct

Low-temperature X-ray detectors for precise Lamb shift measurements on hydrogen-like heavy ions

2000

The precise determination of the Lamb shift in heavy hydrogen-like ions provides a sensitive test of quantum electrodynamics in very strong Coulomb"elds, not accessible otherwise. For the investigation of the Lyman-a transitions in 208Pb81‘ or 238U91‘ with su$cient accuracy a high resolving calorimetric detector for hard X-rays (E)100 keV) is presently developed. The detector modules consist of arrays of silicon thermistors and of X-ray absorbers made of high Z material to optimize the absorption e$ciency. The detectors are housed in a specially designed 3He/4He dilution refrigerator with a side arm which "ts to the geometry of the internal target of the storage ring ESR at GSI Darmstadt. T…

PhysicsNuclear and High Energy PhysicsPhysics::Instrumentation and DetectorsElectric potential energyBinding energyDetectorX-ray detectorHydrogen atomLamb shiftNuclear physicsCoulombAtomic physicsInstrumentationStorage ringNuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment
researchProduct

The X-ray imager on AXO

2001

Abstract DSRI has initiated a development program of CZT X-ray and gamma-ray detectors employing strip readout techniques. A dramatic improvement of the energy response was found operating the detectors as the so-called drift detectors. For the electronic readout, modern ASIC chips were investigated. Modular design and the low-power electronics will make large area detectors using the drift strip method feasible. The performance of a prototype CZT system will be presented and discussed. One such detector system has been proposed for future space missions: the X-Ray Imager (XRI) on the Atmospheric X-ray Observatory (AXO), which is a mission proposed to the Danish Small Satellite Program and …

PhysicsNuclear and High Energy PhysicsPhysics::Instrumentation and Detectorsbusiness.industryAstrophysics::High Energy Astrophysical PhenomenaDetectorAstrophysics::Instrumentation and Methods for AstrophysicsX-ray detectorSpace explorationOpticsApplication-specific integrated circuitObservatorySatelliteElectronicsbusinessInstrumentationEnergy (signal processing)
researchProduct

Polarization phenomena in Al/p-CdTe/Pt X-ray detectors

2013

Over the last decades, CdTe detectors are widely used for the development of room temperature X-ray and gamma ray spectrometers. Typically, high resolution CdTe detectors are fabricated with blocking contacts (indium, aluminum) ensuring low leakage currents and high electric field for optimum charge collection. As well known, time instability under bias voltage (termed as polarization) is the major drawback of CdTe diode detectors. Polarization phenomena cause a progressive degradation of the spectroscopic performance with time, due to hole trapping and detrapping from deep acceptors levels. In this work, we studied the polarization phenomenon on new Al/p-CdTe/Pt detectors, manufactured by …

PhysicsNuclear and High Energy PhysicsSpectrometerPhysics::Instrumentation and Detectorsbusiness.industryX-ray detectorchemistry.chemical_elementBiasingAcceptorCadmium telluride photovoltaicsSchottky CdTe detectorCondensed Matter::Materials SciencechemistryPolarizationElectric fieldActivation energyX-rayandgamma ray spectroscopyOptoelectronicsbusinessPolarization (electrochemistry)InstrumentationIndiumNuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment
researchProduct

Experimental results from Al/p-CdTe/Pt X-ray detectors

2013

Abstract Recently, Al/CdTe/Pt detectors have been proposed for the development of high resolution X-ray spectrometers. Due to the low leakage currents, these detectors allow high electric fields and the pixellization of anodes with the possibility to realize single charge carrier sensing detectors. In this work, we report on the results of electrical and spectroscopic investigations on CdTe diode detectors with Al/CdTe/Pt electrode configuration (4.1×4.1×0.75 and 4.1×4.1×2 mm 3 ). The detectors are characterized by very low leakage currents in the reverse bias operation: 0.3 nA at 25 °C and 2.4 pA at −25 °C under a bias voltage of −1000 V. The spectroscopic performance of the detectors at b…

PhysicsNuclear and High Energy PhysicsSpectrometerbusiness.industryDetectorX-ray detectorBiasingPhoton countingFull width at half maximumElectric fieldOptoelectronicsCharge carrierbusinessInstrumentationNuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment
researchProduct

Nanoscale X-ray detectors based on individual CdS, SnO2 and ZnO nanowires

2021

Abstract The development of nanoscale X-ray sensors is of crucial importance to achieve higher spatial resolution in many X-ray-based techniques playing a key role in materials science, healthcare, and security. Here, we demonstrate X-ray detection using individual CdS, SnO 2 , and ZnO nanowires (NWs). The NWs were produced via vapor–liquid–solid technique and characterized using X-ray diffraction, scanning, and transmission electron microscopy . Electrical measurements were performed under ambient conditions while exposing two-terminal NW-based devices to X-rays generated by a conventional tungsten anode X-ray tube. Fast and stable nanoampere-range X-ray beam induced current (XBIC) in resp…

PhysicsNuclear and High Energy Physicsbusiness.industryNanowireX-ray detectorchemistry.chemical_element02 engineering and technologyTungsten010402 general chemistry021001 nanoscience & nanotechnology01 natural sciences0104 chemical sciencesAnodechemistryTransmission electron microscopyOptoelectronicsCharge carrierElectrical measurements0210 nano-technologybusinessInstrumentationNanoscopic scaleNuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment
researchProduct