Search results for "X-ray detector."
showing 10 items of 42 documents
Charge Transport Properties in CZT Detectors Grown by the Vertical Bridgman Technique
2010
Great efforts are being presently devoted to the development of CdTe and CdZnTe detectors for a large variety of applications, such as medical, industrial, and space research. We present the spectroscopic properties of some CZT crystals grown by the standard vertical Bridgman method and by the boron oxide encapsulated vertical Bridgman method, which has been recently implemented at IMEM-CNR (Parma, Italy). By this technique the crystal is grown in an open quartz crucible fully encapsulated by a thin layer of liquid boron oxide. This method prevents contact between the crystal and the crucible thereby allowing larger single grains with a lower dislocation density to be obtained. Several mono…
The DEPFET based Focal Plane Detectors for MIXS on BepiColombo
2010
X-ray detectors based on arrays of DEPFET macropixels, which consist of a silicon drift detector combined with a detector/amplifier structure DEPFET as readout node, provide a convenient and flexible way to adapt the pixel size of a focal plane detector to the resolving power of any given X-ray optical system. Macropixels combine the traditional benefits of an SDD, like scalability, arbitrary geometry and excellent QE even in the low energy range, with the advantages of DEPFET structures: Charge storage capability, near Fano-limited energy resolution, low power consumption and high speed readout. Being part of the scientific payload of ESA's BepiColombo mission, the MIXS instrument will be …
DEPFET based Instrumentation for the MIXS focal plane on BepiColombo
2009
BepiColombo, ESA's fifth cornerstone mission, is a planetary exploration mission to Mercury. On board of BepiColombo's Mercury Planetary Orbiter (MPO), the MIXS instrument will perform a complete X-ray fluorescence analysis of Mercury's crust with unprecedented spectral and spatial resolution. This is achieved by using a lightweight X-ray mirror system and by using of DEPFET based Macropixel devices as X-ray detectors. DEPFET based Macropixel detectors combine the advantages of the DEPFETs, like flexible readout modes, Fano-limited energy resolution and low power consumption, with the properties of the drift detectors, like arbitrary scalable pixel size and geometry. In addition, the excell…
The wide field imager for the International X-ray Observatory
2009
The large collecting area of the X-ray optics on the International X-ray Observatory (IXO), their good angular resolution, the wide bandwidth of X-ray energies and the high radiation tolerance required for the X-ray detectors in the focal plane have stimulated a new development of devices which unify all those science driven specifications in one single detector. The concept of a monolithic, back-illuminated silicon active pixel sensor (APS) based on the DEPFET structure is proposed for the IXO mission, being a fully depleted, back-illuminated 450 μm thick detector with a physical size of about 10 × 10 cm 2 corresponding to the 18 arcmin field of view. The backside will be covered with an i…
NTD-GE-based microcalorimeter performance
2000
Our group has been developing x-ray microcalorimeters consisting of neutron transmutation doped (NTD) germanium thermistors attached to superconducting tin absorbers. We discuss the performance of single pixel x-ray detectors, and describe an array technology. In this paper we describe the read-out circuit that allows us to measure fast signals in our detectors as this will be important in understanding the primary cause of resolution broadening. We describe briefly a multiplexing scheme that allows a number of different calorimeters to be read out using a single JFET. We list the possible causes of broadening and give a description of the experiment which best demonstrates the cause of the…
Low-temperature X-ray detectors for precise Lamb shift measurements on hydrogen-like heavy ions
2000
The precise determination of the Lamb shift in heavy hydrogen-like ions provides a sensitive test of quantum electrodynamics in very strong Coulomb"elds, not accessible otherwise. For the investigation of the Lyman-a transitions in 208Pb81‘ or 238U91‘ with su$cient accuracy a high resolving calorimetric detector for hard X-rays (E)100 keV) is presently developed. The detector modules consist of arrays of silicon thermistors and of X-ray absorbers made of high Z material to optimize the absorption e$ciency. The detectors are housed in a specially designed 3He/4He dilution refrigerator with a side arm which "ts to the geometry of the internal target of the storage ring ESR at GSI Darmstadt. T…
The X-ray imager on AXO
2001
Abstract DSRI has initiated a development program of CZT X-ray and gamma-ray detectors employing strip readout techniques. A dramatic improvement of the energy response was found operating the detectors as the so-called drift detectors. For the electronic readout, modern ASIC chips were investigated. Modular design and the low-power electronics will make large area detectors using the drift strip method feasible. The performance of a prototype CZT system will be presented and discussed. One such detector system has been proposed for future space missions: the X-Ray Imager (XRI) on the Atmospheric X-ray Observatory (AXO), which is a mission proposed to the Danish Small Satellite Program and …
Polarization phenomena in Al/p-CdTe/Pt X-ray detectors
2013
Over the last decades, CdTe detectors are widely used for the development of room temperature X-ray and gamma ray spectrometers. Typically, high resolution CdTe detectors are fabricated with blocking contacts (indium, aluminum) ensuring low leakage currents and high electric field for optimum charge collection. As well known, time instability under bias voltage (termed as polarization) is the major drawback of CdTe diode detectors. Polarization phenomena cause a progressive degradation of the spectroscopic performance with time, due to hole trapping and detrapping from deep acceptors levels. In this work, we studied the polarization phenomenon on new Al/p-CdTe/Pt detectors, manufactured by …
Experimental results from Al/p-CdTe/Pt X-ray detectors
2013
Abstract Recently, Al/CdTe/Pt detectors have been proposed for the development of high resolution X-ray spectrometers. Due to the low leakage currents, these detectors allow high electric fields and the pixellization of anodes with the possibility to realize single charge carrier sensing detectors. In this work, we report on the results of electrical and spectroscopic investigations on CdTe diode detectors with Al/CdTe/Pt electrode configuration (4.1×4.1×0.75 and 4.1×4.1×2 mm 3 ). The detectors are characterized by very low leakage currents in the reverse bias operation: 0.3 nA at 25 °C and 2.4 pA at −25 °C under a bias voltage of −1000 V. The spectroscopic performance of the detectors at b…
Nanoscale X-ray detectors based on individual CdS, SnO2 and ZnO nanowires
2021
Abstract The development of nanoscale X-ray sensors is of crucial importance to achieve higher spatial resolution in many X-ray-based techniques playing a key role in materials science, healthcare, and security. Here, we demonstrate X-ray detection using individual CdS, SnO 2 , and ZnO nanowires (NWs). The NWs were produced via vapor–liquid–solid technique and characterized using X-ray diffraction, scanning, and transmission electron microscopy . Electrical measurements were performed under ambient conditions while exposing two-terminal NW-based devices to X-rays generated by a conventional tungsten anode X-ray tube. Fast and stable nanoampere-range X-ray beam induced current (XBIC) in resp…