Search results for "Zernike"
showing 10 items of 20 documents
Repeatability of in-vitro optical quality measurements of intraocular lenses with a deflectometry technique effect of the toricity
2018
Aim To evaluate the repeatability of an optical device for measuring the Zernike coefficients of toric intraocular lenses (IOLs) and assess whether its toricity has any impact in its repeatability. Methods An experienced technician used the NIMO TR1504 to measure the Zernike coefficients 30 times for an aperture of 4.50 mm for all lenses included. The IOLs included were divided into two group: toric and non-toric ones. The cylindrical powers of the toric lenses included in the present study were 1.00, 1.50, 2.25, 3.00 and 3.75 D. Finally, the repeatability of the NIMO TR1504 was described in terms of within subject standard deviation (Sw) and repeatability limit. Results The Sw was smaller …
Accommodative Stimulus-Response Curve with Emoji Symbols
2017
Purpose. To evaluate the static measurement of the accommodative stimulus-response curve with emoji symbols. Methods. The accommodative stimulus-response curve was measured in 18 subjects using a Hartmann-Shack sensor to obtain the objective accommodative response from the Zernike defocus term. Measurements were acquired at different accommodative demands, from 0 to 3 D with a step of 0.5 D. Detailed and nondetailed emoji targets were used with two different sizes, corresponding to the two most common visual angles used in smartphones. Results. A regression analysis was performed to fit the mean results obtained for each target. The determination coefficient was R2≥0.988 for all targets. Fo…
Precision of a commercial hartmann-shack aberrometer: limits of total wavefront laser vision correction.
2012
Purpose To assess the intrasession and intersession precision of higher-order aberrations (HOAs) measured using a commercial Hartmann-Shack wavefront sensor (Zywave; Bausch & Lomb) in refractive surgery candidates. Design Prospective, experimental study of a device. Methods To analyze intrasession repeatability, 1 experienced examiner measured 30 healthy eyes 5 times successively. To study intersession reproducibility, the same clinician obtained measurements from another 30 eyes in 2 consecutive sessions at the same time of day 1 week apart. Results For intrasession repeatability, excellent intraclass correlation coefficients (ICCs) were obtained for total ocular aberrations, total HOAs, a…
Optical factors influencing the amplitude of accommodation
2017
AbstractThe purpose of this work was to find plausible predictors among optical parameters that may explain the inter-individual differences in subjective amplitude of accommodation not explained by age. An exploratory multivariable regression analysis was carried out retrospectively on a dataset with 180 eyes from 97 subjects (ages ranged from 20 to 58years). Subjective amplitudes of accommodation were recorded with the use of a custom-made Badal system. A commercial aberrometer was used to obtain each eye’s wavefront during the full range of accommodation. The plausible predictors under study were pupil diameter in the unaccommodated eye, its reduction with accommodation; fourth- and six-…
On-eye optical quality of daily disposable contact lenses for different wearing times
2012
Purpose To quantify the optical quality of various daily disposable contact lenses in vivo and to ascertain its variation in terms of wearing time by means of objective non-invasive determination of wavefront patterns. Methods The crx1 adaptive-optics system was used to measure the wavefront aberrations in 15 myopic eyes before and at 2-h intervals after contact lens fitting, over a 12-h wearing period. Seven types of contact lenses having different material, water content and lens design were evaluated in this study: Dailies Total1, Dailies AquaComfort Plus, Proclear 1 Day, 1-Day Acuvue TruEye, 1-Day Acuvue moist, SofLens daily disposable and Clariti 1-Day. The aberration data were analyse…
New Objective Refraction Metric Based on Sphere Fitting to the Wavefront
2017
Purpose. To develop an objective refraction formula based on the ocular wavefront error (WFE) expressed in terms of Zernike coefficients and pupil radius, which would be an accurate predictor of subjective spherical equivalent (SE) for different pupil sizes.Methods. A sphere is fitted to the ocular wavefront at the center and at a variable distance,t. The optimal fitting distance,topt, is obtained empirically from a dataset of 308 eyes as a function of objective refraction pupil radius,r0, and used to define the formula of a new wavefront refraction metric (MTR). The metric is tested in another, independent dataset of 200 eyes.Results. For pupil radiir0≤2 mm, the new metric predicts the equ…
Automatic Counting of Intra-Cellular Ribonucleo-Protein Aggregates in Saccharomyces cerevisiae Using a Textural Approach.
2019
AbstractIn the context of microbiology, recent studies show the importance of ribonucleo-protein aggregates (RNPs) for the understanding of mechanisms involved in cell responses to specific environmental conditions. The assembly and disassembly of aggregates is a dynamic process, the characterization of the stage of their evolution can be performed by the evaluation of their number. The aim of this study is to propose a method to automatically determine the count of RNPs. We show that the determination of a precise count is an issue by itself and hence, we propose three textural approaches: a classical point of view using Haralick features, a frequency point of view with generalized Fourier…
Accommodation in human eye models: a comparison between the optical designs of Navarro, Arizona and Liou-Brennan.
2017
Aim To simulate and compare accommodation in accommodative and non-accommodative human eye models. Methods Ray tracing and optical design program was used. Three eye models were designed and studied: the Navarro, the Arizona and the Liou-Brennan. In order to make the Navarro and Liou-Brennan models to accommodate, specific geometric parameters of the models were altered with values that were chosen from the literature. For the Arizona model, its' mathematical functions for accommodation were used for the same accommodative demands. The simulation included four distances of accommodation for each model: at infinity, 3, 1 and 0.5 m.The results were diffraction images of a "letter F" for graph…
Redzes uztveres sekcijas referātu tēzes
2011
Optical Quality Comparison between Spherical and Aspheric Toric Intraocular Lenses
2014
Purpose To measure and compare the optical quality of spherical and aspheric toric intraocular lenses (IOLs). Methods Wavefront aberrations of AcrySof Toric and IQ Toric IOLs (Alcon Laboratories) for different powers were measured at 3- and 5-mm pupils by Nimo TR0805 instrument. The Zernike coefficients of trefoil, coma, tetrafoil, secondary astigmatism, and spherical aberration were evaluated. The point spread functions (PSFs) of each IOL evaluated were calculated from the wavefront aberrations. The PSF images also were calculated from the IOL wavefront aberrations, adding the cornea's aberrations to simulate the optical quality after their implantation. Results Spherical toric IOLs showed…