ROTATIONAL TOLERANCES IN ABUTMENT-IMPLANT CONNECTION FOR ORIGINAL AND COMPATIBLE ABUTMENTS
2022
Influence of Implant Connection, Abutment Design and Screw Insertion Torque on Implant-Abutment Misfit
2020
Background: An accurate fit at the implant-abutment interface is an important factor to avoid biological and mechanical complications. The aim of this study was to evaluate the marginal misfit at the implant-abutment interface on external and Morse taper connection, with straight and angulated abutments under different insertion torque loads. Materials and Methods: A total of 120 implants were used, 60 with external connection (EC) and 60 with Morse taper connection (IC). Straight (SA) (n = 60) and angulated abutments (AA) (n = 60) were randomly screwed to each connection at different torque levels (n = 10 each): 10, 20 and 30 Ncm. All specimens were subjected to thermal and cyclic loading …
A new implant-abutment connection for bacterial microleakage prevention: An in vitro study
2017
Purpose The aim of our study is to evaluate the ability of a new type of implant (Konus Implant System®, Industrie biomediche e farmaceutiche, Italy) to isolate the internal of an implant-abutment connection from the external environment. Materials and methods To identify the capability of the implant to protect the internal space from the external environment, the passage of genetically modified Escherichia coli across implant-abutment interface was evaluated. Implants were immerged in a bacterial culture for twenty-four hours and then bacteria amount was measured inside implant-abutment interface with Real-time PCR. Results Bacteria were detected inside all studied implants, with a median…
Removal of failed crown and bridge
2011
Crown and bridge have life span of many years but they fail for a number of reasons. Over the years, many devices have been designed to remove crowns and bridges from abutment teeth. While the removal of temporary crowns and bridges is usually very straightforward, the removal of a definitive cast crown with unknown cement is more challenging. Removal is often by destructive means. There are a number of circumstances, however, in which conservative disassembly would aid the practitioner in completing restorative/endodontic procedures. There are different mechanisms available to remove a failed crown or bridge. But there is no information published about the classification of available syste…
Effect of implant placement depth on the peri-implant bone defect configurations in ligature-induced peri-implantitis : an experimental study in dogs
2018
Background The subcrestal placement of implant platform has been considered a key factor in the preservation of crestal bone, but the influence of implant placement depth on bone remodeling combined with peri-implantitis is not fully understood. The aim of this study was to assess the effect of the crestal or subcrestal placement of implants on peri-implant bone defects of ligature-induced peri-implantitis in dogs. Material and Methods Eight weeks after tooth extraction in six beagle dogs, two different types of implants (A: OsseoSpeed™, Astra, Mölndal, Sweden; B: Integra-CP™, Bicon, Boston, USA) were placed at either crestal or subcrestal (-1.5 mm) positions on one side of the mandible. Li…
Comparison of peri-implant soft tissues in submerged versus transmucosal healing: A split mouth prospective immunohistochemical study
2018
Objective The present split-mouth prospective study involves an immunohistochemical evaluation of peri-implant soft tissue healing after the osseointegration period, comparing submerged and transmucosal approaches using two-piece implant systems. The null hypothesis was that both surgical procedures elicit a similar immune response of the peri-implant soft tissues. Design Thirty-one healthy patients were included in this study, in which two implants were placed in the right and left maxillary pre-molar regions. A total of 62 dental implants were analyzed, establishing a control side with 31 submerged implants, and a study side with 31 exposed implants bearing healing abutments. After a thre…
Microbiological assessment of the implant-abutment interface in different connections: cross-sectional study after 5 years of functional loading.
2014
Objective To evaluate the bacterial microflora present inside the implant connection and in the peri-implant sulcus fluid of healthy implants, and to analyze the relationships between these harboring sites for four different implant systems after at least 5 years of functional loading. Materials and methods A cross-sectional study was performed involving 40 patients treated with metal-ceramic cemented bridges supported by at least two healthy implants functionally loaded for 5 years. Four different implant-abutment connections were studied: external hexagon (control group), double internal hexagon (test group 1), internal hexagon with external collar (test group 2), and conical connection (…
Soft Tissue Response to Titanium Abutments with Different Surface Treatment: Preliminary Histologic Report of a Randomized Controlled Trial
2016
The aim of this preliminary prospective RCT was to histologically evaluate peri-implant soft tissues around titanium abutments treated using different cleaning methods. Sixteen patients were randomized into three groups: laboratory customized abutments underwent Plasma of Argon treatment (Plasma Group), laboratory customized abutments underwent cleaning by steam (Steam Group), and abutments were used as they came from industry (Control Group). Seven days after the second surgery, soft tissues around abutments were harvested. Samples were histologically analyzed. Soft tissues surrounding Plasma Group abutments predominantly showed diffuse chronic infiltrate, almost no acute infiltrate, with …
Platform switch versus platform match in the posterior mandible – 1-year results of a multicentre randomized clinical trial.
2014
Objective The purpose of this ongoing randomized study was to assess differences in bone level changes and success rates using implants supporting single crowns in the posterior mandible either with platform matched or platform switched abutments. Material and Methods Patients aged 18 and above, missing at least two teeth in the posterior mandible and with a natural tooth mesial to the most proximal implant site were enrolled. Randomization followed implant placement. Definitive restorations were placed after a minimum transgingival healing period of 8 weeks. Changes in crestal bone level from surgery and loading (baseline) to 12-month post-loading were radiographically measured. Implant su…
Effect of platform switching on crestal bone levels around implants in the posterior mandible: 3 years results from a multicentre randomized clinical…
2016
Objective Evaluation of differences in the clinical performance and crestal bone levels between implants restored with single crowns with platform-matched or platform-switched abutments after 3 years. Material and Methods The study enrolled adult patients missing two or more adjacent teeth in the posterior mandible with natural teeth mesial to the implant site. Randomization followed open-flap implant insertion and the corresponding matching or switching healing abutments placed at surgery. Conventional loading was made with cemented crowns. Clinical follow-up took place annually after loading up to 3 years. Bone level changes were measured in standardized radiographs as the variation in cr…