Influence of different restorative materials on the stress distribution in dental implants
2018
Background To assist clinicians in deciding the most suitable restorative materials to be used in the crowns and abutment in implant rehabilitation. Material and methods For finite element analysis (FEA), a regular morse taper implant was created using a computer aided design software. The implant was inserted at the bone model with 3 mm of exposed threads. An anatomic prosthesis representing a first maxillary molar was modeled and cemented on the solid abutment. Considering the crown material (zirconia, chromium-cobalt, lithium disilicate and hybrid ceramic) and abutment (Titanium and zirconia), the geometries were multiplied, totaling eight groups. In order to perform the static analysis,…
Marginal Bone Loss in Implants Placed in Grafted Maxillary Sinus
2013
Purpose The purpose of this study is to evaluate the vertical and horizontal graft bone resorption (GR) in grafted maxillary sinuses and the marginal bone loss (MBL) around implants placed in the sinuses with different prosthetic connections and to determine the effect of other clinical factors on these tissue responses at 6 and 18 months postloading. Material and Method A total of 254 implants were placed in 150 grafted maxillary sinuses of 101 patients (51.5% female) with mean age of 52.2 years (range, 32–82 years). GR and MBL measurements were made in implants placed with two different prosthetic connections (internal and external) at 6 and 18 months postloading. The complex samples gene…
Effects of various hygiene procedures on the surface characteristics of titanium abutments.
1996
The use of cleaning instruments on titanium implants may cause undesired surface alterations. In a qualitative and quantitative assessment of these alterations, 5 titanium implant abutments were treated with a steel curet, a prototype pure titanium curet, an air abrasive polishing system, and an ultrasonic system. Custom-made polymer templates, used to secure the curet to a vertical guide bar and a spring scale to maintain a constant instrument pressure, guaranteed a standardized procedure and reproducible results. The ultrasonic and the air abrasive polishing method were also standardized. Evaluation by scanning electron microscopy (SEM) revealed surface alterations for all instruments and…
Tilted implants for the restoration of posterior mandibles with horizontal atrophy: An alternative treatment
2013
Purpose Horizontal atrophy in the posterior mandible presents serious limitations on conventional implant placement. The purpose of this study was to evaluate the use of tilted implants angled in a buccolingual direction for restoring atrophic posterior mandibular sectors. Materials and Methods A cohort study was performed of 25 patients who had partial prostheses supported by more than 1 implant (≥1 tilted and 1 axial implant) to restore molar areas in the mandible. When the bone thickness was at least 5 mm, axial implants were placed; when the alveolar ridge was narrower, the implant was placed with tilted angulation. The beds for these tilted implants were prepared using a lingual approa…
Assessment of the stresses produced on the bone implant/tissue interface to the different insertion angulations of the implant - a three-dimensional …
2020
Background The present study aimed to assess the stresses produced on the surface of the bone tissue around dental implants with three different insertion angulations subjected to axial and oblique loading. Material and methods The study was created according to the recommendations of the Checklist for Reporting In-vitro Studies (CRIS). The Straumann™ bone level RC (4.1 x 10 mm) implant, Cone Morse connection (CM), RC Straumann Variobase™ with abutment (3.5 mm) was placed in the region of element 16, with the platform positioned at the height of the bone crest. Three assessment models were produced: model M1 or control - implant perpendicular to the bone crest; model M2 - implant angulated …
In-vitro fatigue and fracture performance of three different ferrulized implant connections used in fixed prosthesis
2021
Background/purpose: The aim of the present in vitro study was to evaluate fatigue resistance of dental fixtures in three different types of fixture/abutment finishing line. Materials and methods: Transmucosal dental implants, with or without ferrulized neck, underwent fatigue tests (static and dynamic load) using the following standard protocol: UNI EN ISO 14801:2016. Two types of loading devices (screw- or cement-retained restoration) were also tested, and fatigue cycle tests were run to failure. Data of static and dynamic load tests were analyzed by proper statistical methods. Results: Following standard protocol for fatigue testing, the ILC type (Implant Level with ferrulized neck and ce…
Mechanical behavior of implant assisted removable partial denture for Kennedy class II
2019
Made available in DSpace on 2020-12-12T01:22:13Z (GMT). No. of bitstreams: 0 Previous issue date: 2020-01-01 Background: This study evaluated the mechanical response of a removable partial denture (RPD) in Kennedy Class II according to being associated or not with implants. Material and Methods: Four RPDs were manufactured for a Kennedy Class II: CRPD-Conventional RPD, RPD+ 1M, RPD+2M and RPD+12M, respectively, signifying implant assisted RPDs with the implant installed in the first molar, second molar, and in the first and second molars. The finite element method was used to determine the most damaged support tooth under compressive load (300N, 10s) and strain gauge analysis was used to ev…
Accuracy of fit of implant-supported bars fabricated on definitive casts made by different dental stones
2018
Background The purpose of this study was to evaluate the accuracy of fitting of an implant supported screw-retained bar made on definitive casts produced by 4 different dental stone products. Material and Methods The dental stones tested were QuickRock (Protechno), FujiRock (GC), Jade Stone (Whip Mix) and Moldasynt (Heraeus). Three external hexagon implants were placed in a polyoxymethylene block. Definitive impressions were made using monophase high viscosity polyvinylsiloxane in combination with custom trays. Then, definitive models from the different types of dental stones were fabricated. Three castable cylinders with a machined non-enganging base were cast and connected with a very sma…
Preload loss of abutment screws after dynamic fatigue in single implant-supported restorations. A systematic review
2017
Background To carry out a systematic literature review of the causes of preload loss of the abutment screws, of internal and external connection implants, tightened to different torque values and subjected to cyclic loading. Material and methods A systematic search was conducted in PubMed, EMBASE, and Cochrane Library databases with reference to in vitro studies in which internal and external connection implants were subjected to cyclic loads to determine the degree of loosening of the abutment screws after loading. Results The reviewed studies tested distinct implant connections (mostly externally hexed, and morse taper) subjected to diverse cycles (from 16667 to 1 million), with loads ran…
Conical connection adjustment in prosthetic abutments obtained by different techniques
2019
Background The goal of this study is to compare the misfit (>150µm) generated once the restoration, made by different techniques, is retained to a single conical implant. Material and methods 15 internal connection implants (MIS C1 4'20x10mm) are embedded each one perpendicularly to an horizontal surface of the 1x1x2cm poliuretan resin model. The 15 samples obtained are divided in 5 groups depending on the framework process (n=3): 1/casting, 2/overcasting, 3/Ti-base, 4/milling and 5/laser sintering. The cobalt-chromium alloy frameworks are screw-retained to their respective implants to a 30-Ncm torque. Once it is retained the framework to the implant, the next step is to section the sample …