6533b7d3fe1ef96bd12613cb

RESEARCH PRODUCT

Influence of different restorative materials on the stress distribution in dental implants

João Paulo Mendes TribstCarlos-eduardo DatteAlexandre-duarte M. EvangelhistaRenato Sussumu NishiokaAlexandre Luiz Souto BorgesAmanda-maria-de Oliveira Dal PivaMarco Antonio BottinoFabrício M De M. Monteiro

subject

Materials sciencemedicine.medical_treatmentceramic0206 medical engineeringAbutment02 engineering and technologyCrown (dentistry)Stress (mechanics)03 medical and health sciences0302 clinical medicinestomatognathic systemdental implantsBiomaterials and Bioengineering in DentistrymedicineCeramicComposite materialGeneral DentistryElastic modulusStrain gaugeStress concentrationResearchFinite element analysis030206 dentistry:CIENCIAS MÉDICAS [UNESCO]020601 biomedical engineeringvisual_artUNESCO::CIENCIAS MÉDICASvisual_art.visual_art_mediumImplant

description

Background To assist clinicians in deciding the most suitable restorative materials to be used in the crowns and abutment in implant rehabilitation. Material and methods For finite element analysis (FEA), a regular morse taper implant was created using a computer aided design software. The implant was inserted at the bone model with 3 mm of exposed threads. An anatomic prosthesis representing a first maxillary molar was modeled and cemented on the solid abutment. Considering the crown material (zirconia, chromium-cobalt, lithium disilicate and hybrid ceramic) and abutment (Titanium and zirconia), the geometries were multiplied, totaling eight groups. In order to perform the static analysis, the contacts were considered bonded and each material was assigned as isotropic. An axial load (200 N) was applied on the crown and fixation occurred on the base of the bone. Results using Von-Mises criteria and micro strain values were obtained. A sample identical to the CAD model was made for the Strain Gauge (SG) analysis; four SGs were bonded around the implant to obtain micro strain results in bone tissue. Results FEA results were 3.83% lower than SG. According to the crown material, it is possible to note that the increase of elastic modulus reduces the stress concentration in all system without difference for bone. Conclusions Crown materials with high elastic modulus are able to decrease the stress values in the abutments while concentrates the stress in its structure. Zirconia abutments tend to concentrate more stress throughout the prosthetic system and may be more susceptible to mechanical problems than titanium. Key words:Finite element analysis, dental implants, ceramic.

10.4317/jced.54554https://doi.org/10.4317/jced.54554