The impact of restorative material and ceramic thickness on CAD\CAM endocrowns
Made available in DSpace on 2020-12-12T02:39:33Z (GMT). No. of bitstreams: 0 Previous issue date: 2019-01-01 Background: Endocrown restorations as a conservative approach to restore endodontically treated teeth still need an in vitro investigation under fatigue at different materials. This study evaluated the effect of restorative material and restoration thickness on the maximum fracture load of endocrowns subjected to cyclic loading. Material and Methods: Sixty (60) third molar teeth received an endocrown preparation with three different heights of remaining dental tissue (1.5, 3.0 or 4.5 mm). A leucite-based ceramic (LEU) and a lithium disilicate (LD) based ceramic were selected to manuf…
The importance of correct implants positioning and masticatory load direction on a fixed prosthesis
Background Through the biomechanical study of dental implants, it is possible to understand the dissipation effects of masticatory loads in different situations and prevent the longevity of osseointegration. Aims: To evaluate the microstrains generated around external hexagon implants, using axial and non-axial loads in a fixed four-element prosthesis with straight implants and implants inclined at 17°. Material and Methods Three implants were modeled using CAD software following the manufacturer's measurements. Then, implants were duplicated and divided into two groups: one with straight implants and respective abutments, and the other with angled implants at 17° and respective abutments. …
Influence of different restorative materials on the stress distribution in dental implants
Background To assist clinicians in deciding the most suitable restorative materials to be used in the crowns and abutment in implant rehabilitation. Material and methods For finite element analysis (FEA), a regular morse taper implant was created using a computer aided design software. The implant was inserted at the bone model with 3 mm of exposed threads. An anatomic prosthesis representing a first maxillary molar was modeled and cemented on the solid abutment. Considering the crown material (zirconia, chromium-cobalt, lithium disilicate and hybrid ceramic) and abutment (Titanium and zirconia), the geometries were multiplied, totaling eight groups. In order to perform the static analysis,…
Stress distribution of complete-arch implant-supported prostheses reinforced with silica-nylon mesh
Made available in DSpace on 2020-12-12T01:20:51Z (GMT). No. of bitstreams: 0 Previous issue date: 2019-01-01 Background: This study evaluated the presence of a silica-nylon mesh and two cantilever lengths on the biomechanical behavior of complete-arch implant-supported prostheses. Material and Methods: Twenty-four (24) complete mandibular arch implant-supported prostheses were divided into 4 groups according to the presence of reinforcing mesh (with or without) and the cantilever length (molar-15 mm or premolar-5 mm). The specimens were submitted to strain gauge analysis (30-kgf, 10 s) at different points (molar and premolar). Three-dimensional models were created based on the in vitro spec…
Effect of framework type on survival probability of implant-supported temporary crowns : an in vitro study
Made available in DSpace on 2020-12-12T01:29:18Z (GMT). No. of bitstreams: 0 Previous issue date: 2020-01-01 Background: This in vitro study evaluated the effect of framework type on the survival probability of temporary implant-supported crowns and on the implant platform structure after dynamic fatigue. Material and Methods: Thirty (30) external hexagon implants (3.75 x 10 mm) were embedded in acrylic resin following the ISO-14801. Standardized temporary crowns (n=10, N=30) were manufactured in acrylic resin and divided according to the framework type: Total plastic, Plastic with CoCr base and Titanium. The crowns were installed onto the implants (20N. cm) and fatigued (100N, 2 Hz) to det…
Long-term fracture load of all-ceramic crowns: Effects of veneering ceramic thickness, application techniques, and cooling protocol
Made available in DSpace on 2021-06-25T10:46:25Z (GMT). No. of bitstreams: 0 Previous issue date: 2020-11-01 Background: To evaluate, in vitro, the effects of the cooling protocol, application technique, and veneering ceramic thickness on the fracture resistance of ceramic crowns with Y-TZP frameworks. Material and Methods: 80 frameworks were made from zirconia by the CAD/CAM technique and divided into 8 groups (n = 10) according to the factors: “application technique” (stratified-L and pressed -P), “thickness” (1 mm and 2 mm), and “cooling protocol” (slow-S and fast-F) of the feldspathic veneering ceramic. After, all crowns were cemented over G10 preparations with resin cement (Panavia F, …
Effect of active application of self-etching ceramic primer on the long-term bond strength of different dental CAD/CAM materials
Made available in DSpace on 2022-04-29T08:36:43Z (GMT). No. of bitstreams: 0 Previous issue date: 2021-01-01 Background: The objective of this in vitro study was to evaluate the effect of the active application of self-etching ceramic primer (ME&P) on the bond strength of different dental CAD/CAM materials (Lithium Disilicate ceramic (LD), Leucite ceramic (LE), Zirconia reinforced lithium silicate ceramic (ZLS), and Hybrid ceramic (HC)) with thermocycling aging. Material and Methods: The samples were randomly divided into 16 groups (n = 20). Dual resin cement cylinders were made and light cured for 10 s (1.200 mW/cm2) for the shear bond strength test. 3-way ANOVA revealed that the factors w…
Mechanical behavior of implant assisted removable partial denture for Kennedy class II
Made available in DSpace on 2020-12-12T01:22:13Z (GMT). No. of bitstreams: 0 Previous issue date: 2020-01-01 Background: This study evaluated the mechanical response of a removable partial denture (RPD) in Kennedy Class II according to being associated or not with implants. Material and Methods: Four RPDs were manufactured for a Kennedy Class II: CRPD-Conventional RPD, RPD+ 1M, RPD+2M and RPD+12M, respectively, signifying implant assisted RPDs with the implant installed in the first molar, second molar, and in the first and second molars. The finite element method was used to determine the most damaged support tooth under compressive load (300N, 10s) and strain gauge analysis was used to ev…
A study on stress distribution to cement layer and root dentin for post and cores made of CAD/CAM materials with different elasticity modulus in the absence of ferrule
Background To evaluate the stress distribution in a maxillary central incisor with different post and cores made of six CAD/CAM materials with different elastic modulus in the absence of ferrule using the finite element analysis. Material and methods A three-dimensional endodontically treated maxillary central incisor restored with an all-ceramic crown was modelled in Rhinoceros (5.0 SR8, McNeel). The geometries were analyzed in ANSYS 17.2 (ANSYS Inc.) considering isotropic, homogeneous, linearly elastic materials with perfectly bonded contacts. The elastic moduli (E) of the post-and-cores defined the groups to be compared: nanoceramic resin (E=12.8GPa); composite resin (E=16GPa); hybrid ce…
COVID-19 and the impact on the cranio-oro-facial trauma care in Italy:An epidemiological retrospective cohort study
The coronavirus disease 2019 (COVID-19) has deeply modified the organization of hospitals, health care centers, and the patient’s behavior. The aim of this epidemiological retrospective cohort study is to evaluate if and how the COVID-19 pandemic has determined a modification in cranio-oro-facial traumatology service. Methods: The dataset included hospital emergency room access of a six-month pre-pandemic period and six months into pandemic outbreak. The variables collected were: patient age, gender, type of emergency access with relative color code, Glasgow Coma Scale Score, type of discharge. Results: 537 vs. 237 (pre-pandemic vs. pandemic) patients accessed the hospital emergency room an…
Influence of substrate design for in vitro mechanical testing
Background: The goal of this study was to evaluate the influence of dental substrate simulator material, and the presence of root and periodontal ligament on the stress distribution in an adhesively-cemented monolithic crown.Material and methods: Five (5) 3D models according to the substrate simulator material and shape were modeled with CAD software for conducting non-linear finite element analysis (FEA): Tooth with and without periodontal ligament - subgroup "pl" (groups Tooth+pl and Tooth-pl), machined tooth in epoxy-resin with and without pulp chamber - subgroup "pc" (ER+pc and ER-pc) and simplified epoxy-resin substrate without pulp chamber and roots (SiER). Next, adhesively-cemented m…