Search results for "active"

showing 10 items of 5361 documents

Comparison of surfactant-mediated liquid chromatographic modes with sodium dodecyl sulphate for the analysis of basic drugs

2020

In reversed-phase liquid chromatography (RPLC), basic drugs are positively charged at the usual working pH range and interact with free anionic silanols present in conventional silica-based stationary phases. This translates into stronger retention and tailed and broadened peaks. This problem can be resolved by the addition of reagents to the mobile phase that are adsorbed on the stationary phase, avoiding the access of solutes to silanols. Among these additives, surfactants under micellar conditions have provided good silanol suppressing potency through the technique known as micellar liquid chromatography (MLC). The most common example of this is anionic sodium dodecyl sulphate (SDS). Whe…

Chromatography Reverse-PhaseAqueous solutionChromatographyChemistryGeneral Chemical Engineering010401 analytical chemistryGeneral EngineeringSodium Dodecyl Sulfate02 engineering and technology021001 nanoscience & nanotechnology01 natural sciencesMicelle0104 chemical sciencesAnalytical ChemistrySurface-Active AgentsSilanolchemistry.chemical_compoundPulmonary surfactantMicellar liquid chromatographyReagentPhase (matter)Microemulsion0210 nano-technologyMicellesChromatography LiquidAnalytical Methods
researchProduct

Implementation of gradients of organic solvent in micellar liquid chromatography using DryLab®: Separation of basic compounds in urine samples

2014

In micellar liquid chromatography (MLC), chromatographic peaks are more evenly distributed compared to conventional reversed-phase liquid chromatography (RPLC). This is the reason that most procedures are implemented using isocratic elution. However, gradient elution may be still useful in MLC to analyse mixtures of compounds within a wide range of polarities, decreasing the analysis time. Also, it benefits the determination of moderately to low polar compounds in physiological fluids performing direct injection: an initial micellar eluent with a low organic solvent content, or a pure micellar (without surfactant) solution, will provide better protection of the column against the proteins i…

Chromatography Reverse-PhaseChromatographyChemistryElutionChemical polarityAdrenergic beta-AntagonistsOrganic ChemistryAnalytical chemistryGeneral MedicineBiochemistryAnalytical ChemistrySurface-Active Agentschemistry.chemical_compound1-PropanolColumn chromatographyPulmonary surfactantMicellar liquid chromatographyCritical micelle concentrationSolventsHumansIndicators and ReagentsAnalytical proceduresMicellesSoftwareJournal of Chromatography A
researchProduct

Abatement of Acid Orange 7 in macro and micro reactors. Effect of the electrocatalytic route

2014

Abstract The electrochemical treatment of aqueous solutions contaminated by Acid Orange 7 (AO7) was widely studied with the main objective to evaluate as the electrocatalytic route affects the performances of the degradation process in macro and microfluidic cells. Direct anodic oxidation (EO), electro-Fenton (EF), electro-generation of active chlorine (IOAC) and coupled processes were investigated in macro and microfluidic reactors in order to select more effective conditions for the treatment of such compound. The effect of numerous operative parameters (such as nature of the electrode materials, coupling of processes, flow rate, current density and inter-electrode distance) on the perfor…

ChromatographyAqueous solutionSupporting electrolyteChemistryProcess Chemistry and TechnologyElectrocatalysiElectrochemistryElectrocatalystCatalysisCatalysisVolumetric flow rateChemical engineeringMass transferActive chlorineAcid Orange 7Electro-FentonMicroreactorMicro reactorBDDGeneral Environmental Science
researchProduct

Evaluation by HPLC-UV of Polar Pesticides in Rice Fields

1999

ChromatographyChemical PhenomenaChemistry PhysicalHealth Toxicology and MutagenesisPesticide ResiduesOryzaGeneral MedicineHydrogen-Ion ConcentrationPesticideToxicologyPollutionHigh-performance liquid chromatographySurface-Active AgentsSpainEnvironmental sciencePaddy fieldPolarSpectrophotometry UltravioletTrace analysisSample preparationSolid phase extractionPesticidesChromatography High Pressure LiquidHalf-LifeBulletin of Environmental Contamination and Toxicology
researchProduct

Micellar versus hydro-organic reversed-phase liquid chromatography: a solvation parameter-based perspective.

2007

The performance of the solvation parameter model is examined for micellar liquid chromatography. The results are compared with those offered with hydro-organic eluents, intending to reveal the properties that influence the retention and distinguish the particular behaviour of micellar systems. The retention data of several series of non-ionisable and ionisable compounds (mainly steroids, polyaromatic hydrocarbons, phenols, sulfonamides, beta-blockers, phenethylamines, antihistamines, and diuretics) were used as probe compounds. The micellar mobile phases contained an anionic (sodium dodecyl sulphate), non-ionic (Brij-35), or cationic (cetyltrimethylamonium bromide) surfactant, with or witho…

ChromatographyChemistryOrganic ChemistrySolvationIonic bondingGeneral MedicineReversed-phase chromatographyBiochemistryHigh-performance liquid chromatographyAnalytical ChemistryPropanolchemistry.chemical_compoundSurface-Active AgentsMicellar liquid chromatographyBromideSolventsAcetonitrileMicellesChromatography LiquidJournal of chromatography. A
researchProduct

Retention mechanisms in micellar liquid chromatography.

2008

Micellar liquid chromatography (MLC) is a reversed-phase liquid chromatographic (RPLC) mode with mobile phases containing a surfactant (ionic or non-ionic) above its critical micellar concentration (CMC). In these conditions, the stationary phase is modified with an approximately constant amount of surfactant monomers, and the solubilising capability of the mobile phase is altered by the presence of micelles, giving rise to diverse interactions (hydrophobic, ionic and steric) with major implications in retention and selectivity. From its beginnings in 1980, the technique has evolved up to becoming a real alternative in some instances (and a complement in others) to classical RPLC with hydro…

ChromatographyChemistryOrganic ChemistrySolvationIonic bondingGeneral MedicineReversed-phase chromatographyHydrogen-Ion ConcentrationBiochemistryMicelleAnalytical ChemistrySilanolchemistry.chemical_compoundSurface-Active AgentsModels ChemicalSolubilityMicellar liquid chromatographyPhase (matter)Critical micelle concentrationSolventsAdsorptionHydrophobic and Hydrophilic InteractionsAlgorithmsMicellesChromatography LiquidJournal of chromatography. A
researchProduct

Densities, Viscosities, and Refractive Indices of Some Binary Liquid Systems of Methanol + Isomers of Hexanol at 298.15 K

1996

Viscosities, densities, and refractive indices of eight binary liquid systems containing ethanol + some isomers of hexanol have been determined at 298.15 K. The excess property values were fitted to the Redlich-Kister equation to estimate the binary coefficients and the standard deviations.

ChromatographyGeneral Chemical EngineeringAnalytical chemistryBinary numberAlcoholGeneral ChemistryPhysics::Fluid DynamicsViscositychemistry.chemical_compoundMolar volumechemistryBinary systemMethanolPhysics::Chemical PhysicsRefractive indexHexanolJournal of Chemical & Engineering Data
researchProduct

Spectrophotometry: Pharmaceutical Applications

2013

Pharmaceutical analysis is mainly focussed in drug analyses, in raw materials and pharmaceutical formulations, involving the determination of active components, impurities, excipients, content uniformity, solubility, dissolution rate and stability.

ChromatographyMaterials sciencemedicine.diagnostic_testSpectrophotometrymedicineActive componentsSolubilityRaw materialDissolution
researchProduct

Chemical reduction of the mycotoxin beauvericin using allyl isothiocyanate.

2011

Abstract Beauvericin (BEA) is a bioactive compound produced by the secondary metabolism of several Fusarium strains and known to have various biological activities. This study investigated the reduction of BEA present in the concentration of 25 mg/kg on a solution model (phosphate buffer saline at pH 4 and 7) and in wheat flour using allyl isothiocyanate (AITC) as a reactant. The concentration of the mycotoxin studied was evaluated using liquid chromatography coupled to the diode array detector (LC-DAD), whereas adducts formed between the BEA and AITC were examined by liquid chromatography coupled to mass spectrometry-linear ion trap (LC-MS-LIT). In solution, BEA reduction ranged from 20% t…

ChromatographyWheat flourfood and beveragesGeneral MedicineHydrogen-Ion ConcentrationToxicologyAllyl isothiocyanateBeauvericinBioactive compoundMass SpectrometryAdductchemistry.chemical_compoundchemistryChromatography detectorIsothiocyanatesDepsipeptidesIon trapMycotoxinChromatography High Pressure LiquidFood ScienceFood and chemical toxicology : an international journal published for the British Industrial Biological Research Association
researchProduct

A lymphocyte-glia connection sets the pace for smoldering inflammation

2021

Successful therapeutic options directly targeting disability progression in patients with multiple sclerosis (MS), a chronic inflammatory disorder of the central nervous system, are lacking. Now, a study published in Nature by Absinta and colleagues profiles a lymphocyte-glia connection at the edge of chronic active lesions that continuously drives neurodegenerative pathways.

Chronic ActiveLymphocyteMultiple sclerosisCentral nervous systemInflammationBiologymedicine.diseaseChronic inflammatory disorderGeneral Biochemistry Genetics and Molecular Biologymedicine.anatomical_structuremedicineIn patientDisability progressionmedicine.symptomNeuroscienceCell
researchProduct