Search results for "air conditioning"
showing 10 items of 67 documents
SETUP OF VIRTUAL EXPERIMENTS AND CRITICAL ANALYSIS OF CONVENTIONAL THERMOECONOMIC DIAGNOSIS OF MULTIPLE FAULTS IN AIR-CONDENSED ROOFTOP SYSTEMS
2012
The diagnosis of soft faults in vapor compression cooling systems is a crucial activity, since malfunctions may provoke heavy degradation in plant performance and increase the power consumption for space cooling. Among the various Faults Detection and Diagnosis techniques developed over the last two decades, thermoeconomic diagnosis has been playing only a marginal role due to the difficulties encountered when applying the conventional thermoeconomic approaches to vapor compression refrigeration plants. In this paper a critical analysis on capabilities and limits of thermoeconomic diagnosis of refrigeration systems is proposed. The reference plant assumed for this study is a 116 kWc air-con…
Performance maps for an air-cooled air conditioning system as a preliminary instrument for the diagnosis of evaporator fouling
2019
Abstract During the past few decades, there has been increased interest in the development of automated approaches for detecting and diagnosing faults in air conditioning systems. Among them, thermoeconomic diagnosis is a technique which involves the use of exergy analysis. As a first step towards improving its performance, this work is focused on the thermodynamic and exergy analysis of a direct expansion air conditioning system used in small commercial building applications. The analysis was carried out by means of experimental activities on a 17.5 kW rooftop unit installed at the Herrick Laboratories, Purdue University, Indiana (USA). The system under investigation was equipped with a va…
Thermoeconomic Diagnosis of Air conditioning Systems: an Innovative Approach for Improved Reliability of the Technique
2018
Thermoeconomic diagnosis is an exergy-based fault detection and diagnosis technique which has been recently extended to air conditioning systems. One of the main features of this technique is to provide quantitative information of the impact of each fault on the increased energy consumption of a system. This information is then used for programming cost-effective maintenance strategies. Only few papers have focused on it and a lot of work is needed for further improvements. In this work, the approach was developed by means of experimental activities carried out on a 17.5 kW packaged rooftop air conditioning unit (RTU). The RTU was tested in psychrometric chambers under a wide range of opera…
Efficiency improvement of a ground coupled heat pump system from energy management
2011
The installed capacity of an air conditioning system is usually higher than the average cooling or heating demand along the year. So, most of the time, the system is working under its actual capacity. In this contribution, we study the way to improve the efficiency of a ground coupled heat pump air conditioning system by adapting its produced thermal energy to the actual thermal demand. For this purpose, an air conditioning system composed by a ground coupled heat pump and a central fan coil linked to an office located in a cooling dominated area was simulated, and a new management strategy aiming to diminish electrical consumption was developed under the basic constraint that comfort requi…
Analyses of phase change materials’ efficiency in warm-summer humid continental climate conditions
2017
The usage of phase change materials (PCMs) is a way to store excess energy pro- duced during the hot time of the day and release it during the night thereby reducing the overheating problem. While, in Latvian climate conditions overheating is not a big issue in traditional buildings since it happens only a couple of weeks per year air conditioners must still be installed to maintain thermal comfort. The need for cooling in recently built office buildings with large window area can increase signi cantly. It is therefore of great interest if the ther- mal comfort conditions can be maintained by PCMs alone or with reduced maximum power of installed cooling systems. Our initial studies show tha…
Experimental testing of phase change materials in a warm-summer humid continental climate
2019
Abstract The construction industry (and buildings) is one of the largest energy consuming and CO2 emitting sectors in the world. To counter this, more lightweight structures are being used and energy saving applications are being developed. Phase change materials (PCM) are materials that can be considered to tackle these new challenges. It has been proven that PCMs can be passively used to improve the thermal mass of lightweight structures, which improves thermal comfort and reduces peak cooling and heating loads and therefore provides energy savings. To use these materials in an active way, they should be used together with ventilation, cooling or heating equipment, and collectors to accum…
Methodological approach for evaluating the geo-exchange potential: VIGOR Project
2012
In the framework of VIGOR Project, a national project coordinated by the Institute of Geosciences and Earth Resources (CNR-IGG) and sponsored by the Ministry of Economic Development (MiSE), dedicated to the evaluation of geothermal potential in the regions of the Convergence Objective in Italy (Puglia, Calabria, Campania and Sicily), is expected to evaluate the ability of the territory to heat exchange with the ground for air conditioning of buildings. To identify the conditions for the development of low enthalpy geothermal systems collected and organized on a regional scale geological and stratigraphic data useful for the preparation of a specific thematic mapping, able to represent in a …
Changes in surgicaL behaviOrs dUring the CoviD-19 pandemic. The SICE CLOUD19 Study
2021
Abstract Background The spread of the SARS-CoV2 virus, which causes COVID-19 disease, profoundly impacted the surgical community. Recommendations have been published to manage patients needing surgery during the COVID-19 pandemic. This survey, under the aegis of the Italian Society of Endoscopic Surgery, aims to analyze how Italian surgeons have changed their practice during the pandemic. Methods The authors designed an online survey that was circulated for completion to the Italian departments of general surgery registered in the Italian Ministry of Health database in December 2020. Questions were divided into three sections: hospital organization, screening policies, and safety profile of…
Geo-economic variations in epidemiology, patterns of care, and outcomes in patients with acute respiratory distress syndrome: insights from the LUNG …
2017
Background Little information is available about the geo-economic variations in demographics, management, and outcomes of patients with acute respiratory distress syndrome (ARDS). We aimed to characterise the effect of these geo-economic variations in patients enrolled in the Large Observational Study to Understand the Global Impact of Severe Acute Respiratory Failure (LUNG SAFE). Methods LUNG SAFE was done during 4 consecutive weeks in winter, 2014, in a convenience sample of 459 intensive-care units in 50 countries across six continents. Inclusion criteria were admission to a participating intensive-care unit (including transfers) within the enrolment window and receipt of invasive or non…
Ground Coupled Heat Pumps in Mixed Climate Areas: Design, Characterization and Optimization
2010
This contribution reviews the research work developed by the authors on the design, characterization and optimization of ground coupled heat pumps in mixed climates areas. The design of a ground coupled heat pump HVAC system starts with the estimation of the thermal loads that the air-conditioned area demands. The capacity of the ground source airconditioning system is determined from this thermal load estimation. With this value and a proper estimation of the ground thermal properties, the characteristics of the water to water heat pump and the required length and layout of the borehole heat exchangers are estimated. Determining ground thermal properties is crucial for an accurate design o…