Search results for "angle"
showing 10 items of 1921 documents
Advancement genioplasty in Class I patients: predictability and stability of facial profile changes
2011
This retrospective study evaluated the skeletal and soft tissue facial profile changes as well as the predictability and the short-term stability of the soft-tissue response to advancement genioplasty in Class I dental arch relationship patients. The study included 14 adult patients who presented a Class I dental arch but a Class II skeletal arch relationship and underwent advancement genioplasty exclusively. Lateral cephalograms taken immediately preoperatively (T1), immediately postoperatively (T2) and 1 year postoperatively (T3) were analysed. The hard tissue pogonion was sagittally advanced by an average of 7.9 mm (p0.001) (T1-T2). The soft tissue chin followed the sagittal skeletal chi…
Study between anb angle and Wits appraisal in cone beam computed tomography (CBCT)
2013
Objectives: To analyse the ANB and Wits values and to study correlations between those two measurements and other measurements in diagnosing the anteroposterior maxilo-mandibular relationship with CBCT. Study Design: Ninety patients who had previously a CBCT (i-CAT®) as a diagnostic register were selected. A 3D cephalometry was designed using one software package, InVivo5®. This cephalometry included 3 planes of reference, 3 angle measurements and 1 linear measurement. The means and standard deviations of the mean of each measurement were assessed. After that, a Pearson´s correlation coefficient has been performed to analyse the significance of each relationship. Results: When classifying t…
Influence of skeletal class in the morphology of cervical vertebrae: A study using cone beam computed tomography
2016
ABSTRACT Objectives: To quantify the prevalence of cervical vertebrae anomalies and to analyze any association between them and skeletal malocclusions or head posture positions in the same study. Materials and Methods: Two hundred forty patients who were attending the Department of Orthodontics of the University of Valencia for orthodontic treatment were selected and divided into three groups: skeletal Class I (control group, 0° <ANB < 4°), Class II (ANB ≥ 4°), and Class III (ANB ≤ 0°) according to ANB Steiner angle. The morphology of the first five cervical vertebrae was analyzed with cone beam computed tomography to identify any anomalies. Intra- and interobserver error meth…
The mandibular angle in osteoporotic men
2010
Objectives: Osteoporosis induces the reduction of bone mass and screening for low bone mineral density (BMD) by dual-energy x-ray absorptiometry (DXA) has been the current gold standard test to determine osteoporosis. Panoramic radiography is widely used in dentistry for routine examination of jaws. The objective of this study was to determine the relationship between the mandibular angle (MA) values and the vertebral bone mineral density (v-BMD) in 20 osteoporotic men. Study design: In panoramic radiograms of osteoporotic men, the means were calculated for the mandibular angle values measured in the right and left mandible. v-BMD values were also calculated by manual analysis of DXA scans.…
Knowledge about glaucoma in the unselected population: a German survey.
2002
Purpose To determine the general population's knowledge about glaucoma. Materials and methods A representative survey of the German population was conducted in which 2,742 men and women were interviewed face to face. The sample was matched with the German population for age, sex, education, income, and other factors. Questions were asked concerning the nature, occurrence, possible risk factors, and course of glaucoma. Results Fifty-one percent of the population had an active knowledge of the term "glaucoma" and 75% had a passive knowledge of the term. Of those interviewees with a passive knowledge, glaucoma was thought to be associated with raised intraocular pressure (IOP) by 28% and loss …
Analysis of Autoantibodies Against Human Retinal Antigens in Sera of Patients with Glaucoma and Ocular Hypertension
2008
The aim of this study was to show that complex antibody patterns against retinal antigens in sera of patients with glaucoma, found in previous studies, are autoantibodies against human antigens.Sera of 179 patients were collected at the Department of Ophthalmology (University of Mainz, Germany): non-glaucomatous control patients (n=45), primary open-angle glaucoma (n=45), ocular hypertension (n=44), and normal tension glaucoma patients (n=45). The sera were tested against Western blots of human retinal antigens. IgG antibody patterns were analyzed by multivariate statistical techniques, and some significant antigens were identified by mass spectrometry.All subjects, even healthy ones, showe…
Ocular pulse amplitude in patients with open angle glaucoma, normal tension glaucoma, and ocular hypertension.
2002
Intraocular pressure (IOP) is not a fixed constant value but rather has pulsatile components associated with cardiac action. The SmartLens dynamic observing tonometer (odc, Ophthalmic Development Company AG, Zurich, Switzerland) can measure and record simultaneously IOP and ocular pulse amplitude (OPA). It was the aim of this study to evaluate OPA in patients with primary open angle glaucoma (POAG) and high IOP, normal tension glaucoma (NTG), and ocular hypertension (OHT). Furthermore, the authors examined whether there were any correlations with blood pressure.80 subjects were divided into four groups (n=20): 20 patients each with POAG, NTG, and OHT and 20 volunteers without any ocular pat…
Risk factors of ocular hypertension and glaucoma. The Casteldaccia Eye Study.
1994
A case-control study was planned as a part of the Casteldaccia Eye Study in order to investigate about risk factors of ocular hypertension and glaucoma. Cases were 44 subjects with glaucoma or intraocular pressure of 24 mm Hg or more. Controls were 220 subjects with intraocular pressure of 20 mm Hg or less and no signs of glaucoma. A number of environmental, behavioral, systemic and ocular variables were studied. Among the others we investigated the following: sunlight exposure, smoking, alcohol intake, pregnancies, systemic hypertension, diabetes, use of corticosteroids, refractive status, anterior chamber depth, lens nuclear sclerosis, iris color and texture. After univariate analysis the…
Falsely elevated intraocular pressure due to increased central corneal thickness
1999
PURPOSE: To evaluate whether ocular hypertensive subjects have a higher central corneal thickness than other individuals. METHODS: In this prospective study, 48 subjects with ocular hypertension, 63 patients with open-angle glaucoma, 56 nonglaucomatous patients with diabetes mellitus, and 106 control subjects were evaluated. Corneal thickness was measured by ultrasound pachymetry, and intraocular pressure was determined by Goldmann applanation tonometry. RESULTS: Central corneal thickness was significantly higher in the ocular hypertensive subjects, mean +/- S.D., 592+/-39 microm, than in the patients with glaucoma (536+/-34 microm), the nonglaucomatous patients with diabetes mellitus (550+…
Evaluation of the anterior chamber angle in keratoconus and normal subjects.
2015
To evaluate the anterior chamber angle in keratoconus eyes by use of the Visante™ OCT and Orbscan™ II.Anterior chamber angle was measured with the Visante™ OCT and Orbscan™ II in 52 subjects, 26 KC subjects and 26 age and control subjects.When comparing the nasal and temporal angles obtained with the two techniques no correlation was found (R(2) always below 0.01) in either the control subjects or in the KC subjects. Despite this, there was an overall statistically significant difference in mean anterior chamber angles (p0.001) between Visante™ OCT and Orbscan™ II. There was no statistical difference (p0.05) between nasal and temporal anterior chamber angles when comparing controls and KC s…