Search results for "aorta"

showing 10 items of 458 documents

Computer Modeling for the Prediction of Thoracic Aortic Stent Graft Collapse

2011

OBJECTIVE: To assess the biomechanical implications of excessive stent protrusion into the aortic arch in relation to thoracic aortic stent graft (TASG) collapse by simulating the structural load and quantifying the fluid dynamics on the TASG wall protrusion extended into a model arch. METHODS: One-way coupled fluid-solid interaction analyses were performed to investigate the flow-induced hemodynamic and structural loads exerted on the proximal protrusion of the TASG and aortic wall reconstructed from a patient who underwent traumatic thoracic aortic injury repair. Mechanical properties of a Gore TAG thoracic endoprosthesis (W. L. Gore and Assoc, Flagstaff, Ariz) were assessed via experimen…

Aortic archMalemedicine.medical_specialtyAortographymedicine.medical_treatmentHemodynamicsAorta ThoracicFOS: Medical engineeringProsthesis DesignAortographyBlood Vessel Prosthesis ImplantationImaging Three-DimensionalBlood vessel prosthesismedicine.arteryMaterials TestingmedicineHumansComputer Simulationthoracic aortic stent graft (TASG)Aortamedicine.diagnostic_testbusiness.industryEndovascular ProceduresHemodynamicsModels CardiovascularStentSettore ING-IND/34 - Bioingegneria Industrialenutritional and metabolic diseases90399 Biomedical Engineering not elsewhere classifiedCurvatures of the stomachSurgeryBiomechanical PhenomenaBlood Vessel ProsthesisProsthesis FailureEquipment Failure AnalysisRegional Blood FlowRadiographic Image Interpretation Computer-AssistedStentslipids (amino acids peptides and proteins)SurgeryStress Mechanicalbiological phenomena cell phenomena and immunitybusinessNuclear medicineTomography X-Ray ComputedCardiology and Cardiovascular MedicinePerfusionAlgorithmsJournal of Vascular Surgery
researchProduct

Anatomical anomalies and variations of main thoracic vessels in dogs: a computed tomography study.

2019

Abstract Introduction There is scarce information about the prevalence of anomalies and anatomical variations of the main great thoracic vessels in dogs, particularly in dogs without congenital heart disease. Animals The study included 878 privately owned dogs. Material and methods Computerized tomography (CT) thoracic studies carried out between 2011 and 2014 for a variety of reasons were reviewed. The prevalence of anomalies and anatomical variations of the aorta and vena cava, the arterial branches of the aortic arch and the main branches of the intrathoracic veins in dogs with no evidence of congenital heart disease was evaluated. Poor-quality CTs, CTs with thoracic pathology that impai…

Aortic archMalemedicine.medical_specialtyHeart diseasePhysiologyAorta ThoracicRetroesophagealAsymptomaticDogsSpecies SpecificityCatheterization proceduremedicine.arterymedicineAnimalsCommon carotid arteryAortaAortaGeneral Veterinarybusiness.industryThoraxmedicine.diseaseCross-Sectional Studiescardiovascular systemFemaleRadiologyVenae Cavaemedicine.symptomAzygos veinbusinessTomography X-Ray ComputedJournal of veterinary cardiology : the official journal of the European Society of Veterinary Cardiology
researchProduct

Total occlusion of aortic arch in a 62-year-old man presenting with acute myocardial infarction

2011

Not available

Aortic archMalemedicine.medical_specialtyTiclopidineAortic DiseasesMyocardial Infarctionacute myocardial infarctionAorta ThoracicCoronary AngiographyTotal occlusionSettore MED/22 - Chirurgia Vascolaremedicine.arteryInternal medicinemedicineHumansaortic arch occlusionMyocardial infarctionAngioplasty Balloon CoronaryEnoxaparinbusiness.industryGeneral MedicineMiddle Agedmedicine.diseaseClopidogrelaortic arch occlusion myocardial infarction endovascular repair stent-graftCardiologyStentsCardiology and Cardiovascular MedicinebusinessTomography X-Ray Computedcomputed tomography angiography
researchProduct

An In Vitro Phantom Study on the Role of the Bird-Beak Configuration in Endograft Infolding in the Aortic Arch.

2015

Purpose: To assess endograft infolding for excessive bird-beak configurations in the aortic arch in relation to hemodynamic variables by quantifying device displacement and rotation of oversized stent-grafts deployed in a phantom model. Methods: A patient-specific, compliant, phantom pulsatile flow model was reconstructed from a patient who presented with collapse of a Gore TAG thoracic endoprosthesis. Device infolding was measured under different flow and pressure conditions for 3 protrusion extensions (13, 19, and 24 mm) of the bird-beak configuration resulting from 2 TAG endografts with oversizing of 11% and 45%, respectively. Results: The bird-beak configuration with the greatest protr…

Aortic archModels AnatomicRadiology Nuclear Medicine and ImagingTime FactorsFlow modelPulsatile flowEndograftStent-graft oversizingAorta Thoracic030204 cardiovascular system & hematologyRotation0302 clinical medicineForeign-Body MigrationStentThoracic aortaBird-beak configurationmedicine.diagnostic_testEndovascular ProceduresGraft Occlusion VascularModels CardiovascularAnatomyIn vitro experimentProsthesis FailureBlood Vessel ProsthesiTreatment OutcomePulsatile FlowPatient-specific modelStentsCardiology and Cardiovascular MedicineHumanAortographyTime FactorThoracic endovascular aortic repairProsthesis DesignAortographyImaging phantom03 medical and health sciencesBlood Vessel Prosthesis ImplantationBlood vessel prosthesismedicine.arterymedicineHumansDisplacement (orthopedic surgery)HemodynamicEndovascular Procedurebusiness.industryHemodynamicsDisplacementStent-graft infoldingBlood Vessel ProsthesisSurgerybusinessTomography X-Ray Computed030217 neurology & neurosurgeryStent-graft collapseJournal of endovascular therapy : an official journal of the International Society of Endovascular Specialists
researchProduct

Gadolinium-DTPA (Magnevist®) als Kontrastmittel für die arterielle DSA

1994

16 DSA investigations using intra-arterial Gd-DTPA were performed on 12 patients. The contrast medium was administered either as a 0.5 molar gadolinium solution (commercially available) or diluted with distilled water to a 0.2-0.4 molar gadolinium solution. The injection was made either by pressure injector or by hand. The aortic arch, abdominal aorta and pelvic and lower limb arteries were examined. 14 of the 16 procedures were diagnostically adequate, but compared with iodinated contrast materials, contrast was less marked. There were no cardiovascular, neurological or allergic side effects. Three patients suffered a feeling of heat and one patient had mild pain during the injection. Even…

Aortic archMolarmedicine.medical_specialtymedicine.diagnostic_testbusiness.industryGadoliniumAbdominal aortachemistry.chemical_elementIopamidolContrast mediumIodinated contrastchemistrymedicine.arteryAngiographymedicineRadiology Nuclear Medicine and imagingRadiologybusinessNuclear medicinemedicine.drugRöFo - Fortschritte auf dem Gebiet der Röntgenstrahlen und der bildgebenden Verfahren
researchProduct

David V procedure with concomitant ascending aorta, aortic arch and descending aorta replacement in adult patient with coarctation of aorta

2021

Aortic archmedicine.medical_specialtyAortabusiness.industrymedicine.medical_treatmentGeneral surgerymedicine.arteryInternal medicineConcomitantDescending aortaAscending aortamedicineCardiologySurgeryGastrectomybusinessChirurgia
researchProduct

Framework for Fluid-Structure Interaction Analysis of Aortic Coarctation Resulting From Proximal Protusion of Thoracic Aortic Stent Graft Into the Ar…

2011

Thoracic aortic stent grafts (TASG) are commonly used to repair aortic anomalies or diseases in a minimally-invasive fashion. One complication of TASG is collapse, whereby blood is unable to completely flow through the graft as intended. Most TASG collapses occur in the setting of endovascular repair of traumatic thoracic aortic transection, where a typically smaller diameter aorta of pediatric patients is repaired with a relatively larger diameter endograft designed to treat aneurysmal disease [1]. It is hypothesized that the poor apposition of the leading edge of the proximal stent graft to the lesser curvature of the aortic arch can result increased hemodynamic force at the leading side …

Aortic archmedicine.medical_specialtyAortabusiness.industrymedicine.medical_treatmentaorti failureSettore ING-IND/34 - Bioingegneria IndustrialeHemodynamicsStentCurvatures of the stomachSurgeryAppositionsurgical procedures operativemedicine.arteryInternal medicineOcclusioncardiovascular systemCardiologyMedicinebusinessComplicationASME 2011 Summer Bioengineering Conference, Parts A and B
researchProduct

Reference values of fetal aortic flow velocity waveforms and associated intra-observer reliability in normal pregnancies

2001

Objectives It was the aim of the present study to calculate new Doppler reference ranges for blood flow velocities (Vmax, Vmean, Vmin) and resistance indices (PI, RI) for the fetal descending aorta by automatic waveform analysis. Design Cross-sectional prospective study. Subjects Nine hundred and twenty-six low-risk pregnancies at 18–41 weeks' gestation. Methods Aortic blood flow velocities were derived with pulsed-wave color Doppler. Measurements were carried out at the level of the diaphragm. Reference ranges for the individual measuring parameters were constructed based on a growth function from a four-parameter class of monotonic continuous functions according to the smallest square pri…

Aortic archmedicine.medical_specialtyDuplex ultrasonographyAortaRadiological and Ultrasound Technologybusiness.industryObstetrics and GynecologyHemodynamicsGeneral MedicineBlood flowSurgerysymbols.namesakemedicine.anatomical_structureReproductive MedicineInternal medicinemedicine.arteryDescending aortaVascular resistancemedicinesymbolsCardiologyRadiology Nuclear Medicine and imagingbusinessDoppler effectUltrasound in Obstetrics and Gynecology
researchProduct

Assessment of Thoracic Aortic Dimensions in an Experimental Setting: Comparison of Different Unenhanced Magnetic Resonance Angiography Techniques Wit…

2008

PURPOSE To compare different unenhanced magnetic resonance angiography (MRA) techniques for quantitative evaluation of vessel lumen in an experimental setting in young pigs whose dimensions allow for a comparison with a pediatric population. MATERIAL AND METHODS Magnetic resonance imaging was performed in 5 healthy ventilated pigs at 1.5 T. Three different electrocardiogram (ECG)-triggered sequences were applied for MRA: [TSE-Db] T2-weighted dark-blood TurboSpinEcho (2.0 x 1.1 x 4 mm3); [trueFISP] 2D-steady-state-free-precession (2.2 x 1.8 x 2 mm3); [NAV] respiratory-gated, T2-prepared 3D-trueFISP (1.3 x 1.3 x 1.3 mm3). ECG-gated-CT angiography (CTA) (16-row CT, 1 mm collimation) served as …

Aortic archmedicine.medical_specialtySwineContrast MediaAorta ThoracicSensitivity and SpecificityMagnetic resonance angiographyElectrocardiographymedicine.arteryAscending aortaAnimalsHumansMedicineThoracic aortaRadiology Nuclear Medicine and imagingcardiovascular diseasesChildComputed tomography angiographymedicine.diagnostic_testbusiness.industryReproducibility of ResultsMagnetic resonance imagingGeneral MedicineDescending aortaAngiographyRadiologyTomography X-Ray ComputedbusinessNuclear medicineMagnetic Resonance AngiographyInvestigative Radiology
researchProduct

Corrigendum to Patterns of ascending aortic dilatation and predictors of surgical replacement of the aorta: A comparison of bicuspid and tricuspid ao…

2020

The authors regret that the author name of Romano and Raffa are incorrect. The corrected author's name are Romano G and Raffa GM. The authors would like to apologise for any inconvenience caused.

Aortic dilatationAortic valveAortamedicine.medical_specialtybusiness.industrySettore ING-IND/34 - Bioingegneria Industrialeaorta bicuspid aortic valvemedicine.anatomical_structuremedicine.arteryInternal medicinemedicineCardiologyCardiology and Cardiovascular MedicinebusinessMolecular Biology
researchProduct