Search results for "artifacts"
showing 10 items of 105 documents
Why should traceology learn from dental microwear, and vice-versa?
2019
Dental and artifact microwear analyses have a lot in common regarding the questions they address, their developmental history and their issues. However, few paleontologists and archeologists are aware of this, and even those who are, do not take into account most of the methodological insights from the other field. In this focus article, we briefly review the main developmental steps of both methods, highlight how similar their histories are and how combining methodological developments can improve both research fields. In both cases, the traditional analyses have been strongly criticized mainly because of their subjectivity and their lack of repeatability and reproducibility. Quantitative …
Mobile manipulator performance measurement towards manufacturing assembly tasks
2016
Mobile manipulator performance measurement research is relatively minimal as compared to that of robot arms. Measurement methods, such as optical tracking systems, are useful for measuring the performance of mobile manipulators, although at a much higher relative cost as compared to artifacts. The concept of using test artifacts demonstrates to potential manufacturers and users of mobile manipulator systems that relatively low cost performance measurement methods exist. This paper discusses the concept of reconfigurable mobile manipulator artifacts that were designed and built. An artifact was then used through experimentation to measure the performance of a mobile manipulator to demonstrat…
Potential Second-Harmonic Ghost Bands in Fourier Transform Infrared (FT-IR) Difference Spectroscopy of Proteins
2018
Fourier transform infrared (FT-IR) difference absorption spectroscopy is a common method for studying the structural and dynamical aspects behind protein function. In particular, the 2800–1800 cm−1 spectral range has been used to obtain information about internal (deuterated) water molecules, as well as site-specific details about cysteine residues and chemically modified and artificial amino acids. Here, we report on the presence of ghost bands in cryogenic light-induced FT-IR difference spectra of the protein bacteriorhodopsin. The presence of these ghost bands can be particularly problematic in the 2800–1900 cm−1 region, showing intensities similar to O–D vibrations from water molecules…
Flexible multi-beam light-sheet fluorescence microscope for live imaging without striping artifacts
2018
The development of light-sheet fluorescence microscopy (LSFM) has greatly expanded the experimental capabilities in many biological and biomedical research fields, enabling for example live studies of murine and zebrafish neural activity or of cell growth and division. The key feature of the method is the selective illumination of a sample single plane, providing an intrinsic optical sectioning and allowing direct 2D image recording. On the other hand, this excitation scheme is more affected by absorption or scattering artifacts in comparison to point scanning methods, leading to un-even illumination. We present here an easily implementable method, based on acousto-optical deflectors (AOD),…
Chimeric proteins tagged with specific 3xHA cassettes may present instability and functional problems
2017
Epitope-tagging of proteins has become a widespread technique for the analysis of protein function, protein interactions and protein localization among others. Tagging of genes by chromosomal integration of PCR amplified cassettes is a widely used and fast method to label proteins in vivo. Different systems have been developed during years in the yeast Saccharomyces cerevisiae. In the present study, we analysed systematically a set of yeast proteins that were fused to different tags. Analysis of the tagged proteins revealed an unexpected general effect on protein level when some specific tagging module was used. This was due in all cases to a destabilization of the proteins and caused a red…
MetProc: Separating Measurement Artifacts from True Metabolites in an Untargeted Metabolomics Experiment
2019
High-throughput metabolomics using liquid chromatography and mass spectrometry (LC/MS) provides a useful method to identify biomarkers of disease and explore biological systems. However, the majority of metabolic features detected from untargeted metabolomics experiments have unknown ion signatures, making it critical that data should be thoroughly quality controlled to avoid analyzing false signals. Here, we present a postalignment method relying on intermittent pooled study samples to separate genuine metabolic features from potential measurement artifacts. We apply the method to lipid metabolite data from the PREDIMED (PREvención con DIeta MEDi-terránea) study to demonstrate clear remova…
Enhanced field-of-view integral imaging display using multi-Köhler illumination.
2014
A common drawback in 3D integral imaging displays is the appearance of pseudoimages beyond the viewing angle. These pseudoimages appear when the light rays coming from each elemental image are not passing through the corresponding microlens, and a set of barriers must be used to avoid this flipping effect. We present a pure optical arrangement based on Köhler illumination to generate these barriers thus avoiding the pseudoimages. The proposed system does not use additional lenses to project the elemental images, so no optical aberrations are introduced. As an added benefit, Köhler illumination provides a higher contrast 3D display. This work was supported in part by the Plan Nacional I + D …
Adaptive scheduling of acceleration and gyroscope for motion artifact cancelation in photoplethysmography
2022
Background and objective: Recently, various algorithms have been introduced using wrist-worn photo-plethysmography (PPG) to provide high accuracy of instantaneous heart rate (HR) estimation, including during high-intensity exercise. Most studies focus on using acceleration and/or gyroscope signals for the motion artifact (MA) reference, which attenuates or cancels out noise from the MA-corrupted PPG signals. We aim to open and pave the path to find an appropriate MA reference selection for MA cancelation in PPG.Methods: We investigated how the acceleration and gyroscope reference signals correlate with the MAs of the distorted PPG signals and derived both mathematically and experimentally a…
Systematic review on spheroids from adipose‐derived stem cells: Spontaneous or artefact state?
2022
Three-dimensional (3D) cell cultures represent the spontaneous state of stem cells with specific gene and protein molecular expression that are more alike the in vivo condition. In vitro two-dimensional (2D) cell adhesion cultures are still commonly employed for various cellular studies such as movement, proliferation and differentiation phenomena; this procedure is standardized and amply used in laboratories, however their representing the original tissue has recently been subject to questioning. Cell cultures in 2D require a support/substrate (flasks, multiwells, etc.) and use of fetal bovine serum as an adjuvant that stimulates adhesion that most likely leads to cellular aging. A 3D envi…
Focal airtrapping at expiratory high-resolution CT: comparison with pulmonary function tests
2000
This study was undertaken to determine prevalence, extent, and severity of focal airtrapping at expiratory high-resolution CT, and to compare focal airtrapping with age, gender, pulmonary function tests, and blood gas analysis. Two-hundred seventeen patients with and without pulmonary disease underwent paired inspiratory/expiratory high-resolution CT. Six scan pairs with corresponding scan levels were visually assessed for focal – not diffuse – airtrapping using a four-point scale. Pulmonary function tests and blood gas analysis were available for correlation in all patients (mean interval 5 days). Focal airtrapping with lower lung predominance was observed in 80 % of patients. Twenty-six o…