Search results for "atomic force"
showing 10 items of 308 documents
Identification of lead pigments in nanosamples from ancient paintings and polychromed sculptures using voltammetry of nanoparticles/atomic force micr…
2007
Voltammetry of nanoparticles coupled with atomic force microscopy was used to identify lead pigments in nanosamples proceeding from works of art. Upon mechanical attachment of few nanograms of sample to a graphite plate, well-defined voltammetric responses were obtained for lead orange, lead yellow, lead white, litharge, minium, Naples yellow, and tin-lead yellow, allowing for an unambiguous identification of such pigments. Atomic force images provide evidence for the occurrence of pigment-characteristic reduction processes accompanied by metal deposition on the graphite substrate. Electrochemical parameters are used for pigment identification. Application to the method for identifying lead…
Force Measurements on Myelin Basic Protein Adsorbed to Mica and Lipid Bilayer Surfaces Done with the Atomic Force Microscope
1999
The mechanical and adhesion properties of myelin basic protein (MBP) are important for its function, namely the compaction of the myelin sheath. To get more information about these properties we used atomic force microscopy to study tip-sample interaction of mica and mixed dioleoylphosphatidylserine (DOPS) (20%)/egg phosphatidylcholine (EPC) (80%) lipid bilayer surfaces in the absence and presence of bovine MBP. On mica or DOPS/EPC bilayers a short-range repulsive force (decay length 1.0-1.3 nm) was observed during the approach. The presence of MBP always led to an attractive force between tip and sample. When retracting the tip again, force curves on mica and on lipid layers were different…
Core-Shell Microgels with Switchable Elasticity at Constant Interfacial Interaction.
2016
Hydrogels based on poly(N-isopropylacrylamide) (pNIPAAm) exhibit a thermo-reversible volume phase transition from swollen to deswollen states. This change of the hydrogel volume is accompanied by changes of the hydrogel elastic and Young's moduli and of the hydrogel interfacial interactions. To decouple these parameters from one another, we present a class of submillimeter sized hydrogel particles that consist of a thermosensitive pNIPAAm core wrapped by a nonthermosensitive polyacrylamide (pAAm) shell, each templated by droplet-based microfluidics. When the microgel core deswells upon increase of the temperature to above 34 °C, the shell is stretched and dragged to follow this deswelling i…
Phase Transition of Individually Addressable Microstructured Membranes Visualized by Imaging Ellipsometry
2007
The phase transition of individually addressable microstructured lipid bilayers was investigated by means of imaging ellipsometry. Microstructured bilayers were created on silicon substrates by micromolding in capillaries, and the thermotropic behavior of various saturated diacyl phosphatidylcholine (1,2-dipalmitoyl-sn-glycero-3-phosphocholine, 1,2-dipentadecoyl-sn-glycero-3-phosphocholine, and 1,2-dimyristoyl-sn-glycero-3-phosphocholine (DMPC)) bilayers as well as DMPC/cholesterol membranes was determined by measuring the area expansion and thickness of the bilayer as a function of temperature. We found an increase in the main phase transition temperature T(M) of 2-6 degrees C and a substa…
Thermal Expansion of Microstructured DMPC Bilayers Quantified by Temperature-Controlled Atomic Force Microscopy
2006
Facile synthesis of L-cysteine functionalized graphene quantum dots as a bioimaging and photosensitive agent
2021
Nowadays, a larger number of aggressive and corrosive chemical reagents as well as toxic solvents are used to achieve structural modification and cleaning of the final products. These lead to the production of residual, waste chemicals, which are often reactive, cancerogenic, and toxic to the environment. This study shows a new approach to the modification of graphene quantum dots (GQDs) using gamma irradiation where the usage of reagents was avoided. We achieved the incorporation of S and N atoms in the GQD structure by selecting an aqueous solution of L-cysteine as an irradiation medium. GQDs were exposed to gamma-irradiation at doses of 25, 50 and 200 kGy. After irradiation, the optical,…
Modification of Structural and Luminescence Properties of Graphene Quantum Dots by Gamma Irradiation and Their Application in a Photodynamic Therapy
2015
Herein, the ability of gamma irradiation to enhance the photoluminescence properties of graphene quantum dots (GQDs) was investigated. Different doses of gamma-irradiation were used on GQDs to examine the way in which their structure and optical properties can be affected. The photoluminescence quantum yield was increased six times for the GQDs irradiated with high doses compared to the nonirradiated material. Both photoluminescence lifetime and values of optical band gap were increased with the dose of applied gamma irradiation. In addition, the exploitation of the gamma-irradiated GQDs as photosensitizers was examined by monitoring the production of singlet oxygen under UV illumination. T…
Themes of nanoscience for the introductory physics course
2009
We present three experimental themes and one discussion theme that proved to be suitable for introducing nanoscience through topics that can be integrated into the existing introductory physics or teacher training courses. The experimental themes include two teaching models of an atomic force microscope (AFM) and an experiment with an elastic optical grating. They are all based on simple experiments that give also quantitative results and can be explained using basic physics theory.
Frequency-modulated atomic force microscopy operation by imaging at the frequency shift minimum: the dip-df mode.
2014
In frequency modulated non-contact atomic force microscopy, the change of the cantilever frequency (Delta f) is used as the input signal for the topography feedback loop. Around the Delta f(z) minimum, however, stable feedback operation is challenging using a standard proportional-integral-derivative (PID) feedback design due to the change of sign in the slope. When operated under liquid conditions, it is furthermore difficult to address the attractive interaction regime due to its often moderate peakedness. Additionally, the Delta f signal level changes severely with time in this environment due to drift of the cantilever frequency f(0) and, thus, requires constant adjustment. Here, we pre…
Towards an atomistic understanding of solid friction by computer simulations
2002
Friction between two solid bodies in sliding motion takes place on a large spectrum of length and time scales: From the nanometer/second scale in an atomic force microscope up to the extremely macroscopic scales of tectonic motion. Despite our familiarity with friction, fundamental questions about its atomistic origins remain unanswered. Phenomenological laws that describe the friction in many systems were published more than 300 years ago by Amontons: The frictional force is proportional to the applied load and independent of the apparent area of contact. The atomistic origins of this simple law is still controversial. Many explanations, which seemed to be well-established until recently, …