Search results for "avalanche"

showing 10 items of 23 documents

AX-PET: Concept, proof of principle and first results with phantoms

2010

AX-PET is a novel PET concept based on long crystals axially arranged and orthogonal Wavelength shifter (WLS) strips, both individually readout by Geiger-mode Avalanche Photo Diodes (G-APD). Its design was conceived in order to reduce the parallax error and simultaneously improve spatial resolution and sensitivity. The assessment of the AX-PET concept and potential was carried out through a set of measurements comprising individual module characterizations and scans in coincidence mode of point-like and extended sources. The estimated energy and spatial resolutions from point-like measurements are R FWHM =11.6% (at 511 keV) and 1.7–1.9 mm (FWHM) respectively as measured with point-like sour…

Coincidence modePhysicsbusiness.industryExtended sourcesSTRIPSIterative reconstructionConcept-basedWavelength shifterAvalanche photodiodeCoincidencelaw.inventionOpticslawCoincidence mode; Concept-based; Extended sourcesbusinessParallaxImage resolutionDiodeIEEE Nuclear Science Symposuim & Medical Imaging Conference
researchProduct

Metal frame as local protection of superconducting films from thermomagnetic avalanches

2016

Thermomagnetic avalanches in superconducting films propagating extremely fast while forming unpredictable patterns, represent a serious threat for the performance of devices based on such materials. It is shown here that a normal-metal frame surrounding a selected region inside the film area can provide efficient protection from the avalanches during their propagation stage. Protective behavior is confirmed by magneto-optical imaging experiments on NbN films equipped with Cu and Al frames, and also by performing numerical simulations. Experimentally, it is found that while conventional flux creep is not affected by the frames, the dendritic avalanches are partially or fully screened by them…

Materials sciencemetal framesthermomagnetic avalanchesFOS: Physical sciencesGeneral Physics and AstronomyFluxchemistry.chemical_element02 engineering and technology01 natural sciencesSuperconductivity (cond-mat.supr-con)AluminiumCondensed Matter::Superconductivity0103 physical sciences010306 general physicsSuperconductivitysuperconducting filmsResistive touchscreenta114Condensed matter physicsCondensed Matter - SuperconductivityConductanceThermomagnetic convection021001 nanoscience & nanotechnologyAvalanche breakdownlcsh:QC1-999Creepchemistry0210 nano-technologylcsh:PhysicsAIP Advances
researchProduct

Beam test measurements of Low Gain Avalanche Detector single pads and arrays for the ATLAS High Granularity Timing Detector

2018

For the high luminosity upgrade of the LHC at CERN, ATLAS is considering the addition of a High Granularity Timing Detector (HGTD) in front of the end cap and forward calorimeters at |z|= 3.5 m and covering the region 2.4 <|η|< 4 to help reducing the effect of pile-up. The chosen sensors are arrays of 50 μm thin Low Gain Avalanche Detectors (LGAD). This paper presents results on single LGAD sensors with a surface area of 1.3×1.3 mm2 and arrays with 2×2 pads with a surface area of 2×2 mm2 or 3×3 mm2 each and different implant doses of the p+ multiplication layer. They are obtained from data collected during a beam test campaign in autumn 2016 with a pion beam of 120 GeV energy at the CERN SP…

Physics - Instrumentation and DetectorsPhysics::Instrumentation and Detectorsionization: yieldFOS: Physical sciences01 natural sciencesTiming detectorsParticle detectorHigh Energy Physics - ExperimentHigh Energy Physics - Experiment (hep-ex)OpticsAtlas (anatomy)0103 physical sciencesmedicine[PHYS.PHYS.PHYS-INS-DET]Physics [physics]/Physics [physics]/Instrumentation and Detectors [physics.ins-det]Detectors and Experimental TechniquesSolid state detectors010306 general physicsphysics.ins-det[ PHYS.PHYS.PHYS-INS-DET ] Physics [physics]/Physics [physics]/Instrumentation and Detectors [physics.ins-det]Instrumentationspatial resolutiontime resolutionMathematical PhysicsPhysicsLarge Hadron ColliderLuminosity (scattering theory)010308 nuclear & particles physicsbusiness.industryHigh Energy Physics::PhenomenologyDetectorInstrumentation and Detectors (physics.ins-det)ATLASSi microstrip and pad detectorsSemiconductor detectormedicine.anatomical_structurepile-upavalancheefficiencyPhysics::Accelerator Physicssemiconductor detectorHigh Energy Physics::ExperimentGranularitybusinessBeam (structure)
researchProduct

Evaluation of a commercial APD array (Avalanche PhotoDiode) for a readout detector in a hadrontherapy beam characterization application

2010

The aim of the present work is the characterization of the S8898–128–02 Avalanche PhotoDiode array (APDs) from Hamamatsu Photonics. This work includes the implementation of a readout system as well as electronic noise estimation in APDs under several conditions varying integration times and clock frequencies.

PhysicsAPDSPhysics::Instrumentation and Detectorsbusiness.industryPhysics::Medical PhysicsDetectorAstrophysics::Instrumentation and Methods for AstrophysicsAvalanche photodiodeNoise (electronics)law.inventionlawNuclear electronicsOptoelectronicsPhotonicsbusinessField-programmable gate arrayBeam (structure)IEEE Nuclear Science Symposuim &amp; Medical Imaging Conference
researchProduct

Production altitude and time delays of the terrestrial gamma flashes: Revisiting the Burst and Transient Source Experiment spectra

2008

[1] On the basis of the RHESSI results it has been suggested that terrestrial gamma flashes (TGFs) are produced at very low altitudes. On the other hand some of the Burst and Transient Source Experiment (BATSE) spectra show unabsorbed fluxes of X rays in the 25–50 keV energy range, indicating a higher production altitude. To investigate this, we have developed a Monte Carlo code for X-ray propagation through the atmosphere. The most important features seen in the modeled spectra are (1) a low-energy cutoff which moves to lower energies as TGFs are produced at higher altitudes, (2) a high-energy cutoff which moves to lower energies as TGFs are observed at larger zenith angles, and (3) time d…

PhysicsAtmospheric ScienceEcologyAstrophysics::High Energy Astrophysical PhenomenaCompton scatteringPaleontologySoil ScienceForestryAstrophysicsAquatic ScienceOceanographySpectral lineAtmosphereGeophysicsAltitudeRelativistic runaway electron avalancheSpace and Planetary ScienceGeochemistry and PetrologyPhysics::Space PhysicsEarth and Planetary Sciences (miscellaneous)Atmospheric electricityZenithEarth-Surface ProcessesWater Science and TechnologyTerrestrial gamma-ray flashJournal of Geophysical Research: Space Physics
researchProduct

Test and Simulation of a LYSO+APD matrix with a tagged Photon Beam from 40 to 300 MeV

2012

Understanding the energy resolution terms for LYSO based calorimeters with APD readout at low energy (< 500 MeV) is relevant both for the completion of the KLOE-2 experiment, at DAΦNE, and for the design of the Mu2e calorimeter. In this work, we present a dedicated comparison between experimental data, taken in 2011 at the MAMI tagged photon beam facility with a crystal matrix prototype, and a full Geant-4 simulation of this detector. The crystal prototype matrix consisted of 9 2×2 × 15 cm3 LYSO crystals read-out by 10×10 mm2 Hamamatsu avalanche photodiodes (APD) surrounded by 8 PbWO4 crystals read-out by Bialkali photomultipliers for outer leakage recovery granting a total transverse cover…

PhysicsHistoryPhotomultiplierbusiness.industryAvalanche photodiodeNoise (electronics)Particle detectorLyso-Computer Science ApplicationsEducationCalorimeterPhotodiodelaw.inventionOpticslawMu2ebusinessJournal of Physics: Conference Series
researchProduct

The backward end-cap for the PANDA electromagnetic calorimeter

2015

The PANDA experiment at the new FAIR facility will cover a broad experimental programme in hadron structure and spectroscopy. As a multipurpose detector, the PANDA spectrometer needs to ensure almost 4π coverage of the scattering solid angle, full and accurate multiple-particle event reconstruction and very good particle identification capabilities. The electromagnetic calorimeter (EMC) will be a key item for many of these aspects. Particle energies ranging from some MeVs to several GeVs have to be measured with a relative resolution of 1% ⊕ 2%/√E/GeV . It will be a homogeneous calorimeter made of PbWO4 crystals and will be operated at -25°C, in order to improve the scintillation light yiel…

PhysicsHistoryScintillationSpectrometerCalorimeter (particle physics)APDSPhysics::Instrumentation and Detectorsbusiness.industryDetectorAvalanche photodiodeParticle identificationComputer Science ApplicationsEducationlaw.inventionNuclear physicsOpticslawNuclear ExperimentbusinessEvent reconstructionJournal of Physics: Conference Series
researchProduct

Background and muon counting rates in underground muon measurements with a plastic scintillator counter based on a wavelength shifting fibre and a mu…

2010

AbstractIn this short note we present results of background measurements carried out with polystyrene based cast plastic 12.0×12.0×3.0 cm3 size scintillator counter with a wavelength shifting fibre and a multi-pixel Geiger mode avalanche photodiode readout in the Baksan underground laboratory at a depth of 200 metres of water equivalent. The total counting rate of the scintillator counter measured at this depth and at a threshold corresponding to ∼0.37 of a minimum ionizing particle is approximately 1.3 Hz.

PhysicsMuonPixelbusiness.industryPhysics::Instrumentation and DetectorsPhysicsQC1-999radioactivity backgroundGeneral Physics and AstronomyCosmic rayScintillatorAvalanche photodiodeplastic scintillatormulti-pixel avalanche photodiodeWavelengthOpticsmuonOptoelectronicsGeiger mode avalanche photodiodebusinessCounting ratecosmic rayOpen Physics
researchProduct

Time response of avalanche photodiodes as a function of the internal gain

1998

Abstract Using a red LED and a blue laser as a light source, time response of avalanche photodiodes and Metal-Resistive Silicon (MRS) layer avalanche photodiodes [1] has been measured. A strong dependence of the time resolution on the internal gain has been observed. The obtained results show that the increase of the internal gain improves the time resolution. However, there exists a critical value for the internal gain. Beyond this value a deterioration of the time resolution is observed.

PhysicsNuclear and High Energy PhysicsBlue laserAvalanche diodeSiliconbusiness.industrychemistry.chemical_elementFunction (mathematics)Critical valueAvalanche photodiodeOpticsTime responsechemistrySingle-photon avalanche diodeOptoelectronicsbusinessInstrumentationNuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment
researchProduct

Multi-pixel Geiger-mode avalanche photodiode and wavelength shifting fibre readout of plastic scintillator counters of the EMMA underground experiment

2009

The results of a development of a scintillator counter with wavelength shifting (WLS) fibre and a multi-pixel Geiger-mode avalanche photodiode readout are presented. The photodiode has a metal-resistor-semiconductor layered structure and operates in the limited Geiger mode. The scintillator counter has been developed for the EMMA underground cosmic ray experiment.

PhysicsNuclear and High Energy PhysicsOptical fiberPhysics - Instrumentation and DetectorsPixelbusiness.industryPhysics::Instrumentation and DetectorsAstrophysics::Instrumentation and Methods for AstrophysicsFOS: Physical sciencesPhysics::Physics EducationCosmic rayInstrumentation and Detectors (physics.ins-det)ScintillatorAvalanche photodiodePhotodiodelaw.inventionWavelengthOpticslawGeiger counterOptoelectronicsbusinessInstrumentation
researchProduct