Search results for "ballo"

showing 10 items of 269 documents

A rare case of Prinzmetal angina 3 days after coronary artery stenting with a second-generation drug-eluting stent

2015

Non previsto.

Angina Pectoris VariantMaleCoronary angiographymedicine.medical_specialtyTime FactorsVasodilator Agentsmedicine.medical_treatmentCoronary VasospasmPrinzmetal angina coronary artery stenting stent second-generation drug-eluting stent.Coronary AngiographyProsthesis DesignBalloonAnginaAngioplastyInternal medicineRare caseHumansMedicineEverolimusAngioplasty Balloon CoronarySirolimusEverolimusbusiness.industryCoronary StenosisCardiovascular AgentsDrug-Eluting StentsGeneral MedicineMiddle Agedmedicine.diseaseSettore MED/11 - Malattie Dell'Apparato CardiovascolareTreatment Outcomemedicine.anatomical_structureDrug-eluting stentCardiologyPrinzmetal angina coronary artery stentingdrug-eluting stentCardiology and Cardiovascular Medicinebusinessmedicine.drugArteryCoronary Artery Disease
researchProduct

Metabolites from Mediterranean plants: characterization and transformation. Chemotaxonomic assessment and biological activity.

Questo progetto di ricerca ha lo scopo di ampliare le conoscenze di alcune piante appartenenti alla flora Mediterranea. Le piante da studiare sono state scelte in seguito ad un’attenta analisi bibliografica tra specie poco sudiate. La scelta è quindi ricaduta su nove specie appartenenti al genere Anthemis, due specie appartenenti al genere Pulicaria e sulle specie di Tetraclinis articulata, Salvia argentea, Ajuga tenorei, Ballota hispanica, Moluccella Spinosa e Thapsia garganica. Di esse sono stati preparati ed identificati i componenti degli oli essenziali e successivamente effettuati su di essi i saggi antibatterici. Dagli estratti delle specie di Tetraclinis articulata e Ajuga tenorei so…

Anthemis Pulicaria Salvia argentea Thapsia garganica Tetraclinis articulata Ajuga tenorei Ballota hispanica Moluccella spinosa essential oils from mediterranean plants.Settore CHIM/06 - Chimica Organica
researchProduct

Selling a vote

2005

Abstract A voting function is a rule that determines the outcome of an election: taking the voters' votes as input, a voting function selects the winning candidate from the set of candidates receiving some vote. A voting function is immune to vote selling when, given that neither voter i nor voter j votes for the winning candidate, a change ceteris paribus in i's vote cannot make the candidate for which j votes the winner. It is shown that voting functions immune to vote selling have either a dictator (a voter who always determines the winning candidate) or a dictated candidate (a candidate who becomes the winner by just receiving some vote).

Anti-plurality votingEconomics and EconometricsPublic economicsSpoilt voteCounting single transferable votesComputingMilieux_LEGALASPECTSOFCOMPUTINGCondorcet methodCardinal voting systemsMicroeconomicsContingent votePolitical Science and International RelationsBullet votingEconomicsExhaustive ballotEuropean Journal of Political Economy
researchProduct

Total occlusion of aortic arch in a 62-year-old man presenting with acute myocardial infarction

2011

Not available

Aortic archMalemedicine.medical_specialtyTiclopidineAortic DiseasesMyocardial Infarctionacute myocardial infarctionAorta ThoracicCoronary AngiographyTotal occlusionSettore MED/22 - Chirurgia Vascolaremedicine.arteryInternal medicinemedicineHumansaortic arch occlusionMyocardial infarctionAngioplasty Balloon CoronaryEnoxaparinbusiness.industryGeneral MedicineMiddle Agedmedicine.diseaseClopidogrelaortic arch occlusion myocardial infarction endovascular repair stent-graftCardiologyStentsCardiology and Cardiovascular MedicinebusinessTomography X-Ray Computedcomputed tomography angiography
researchProduct

Transcervical approach for carotid artery stenting with transitory reversal flow: Case report

2021

Introduction Carotid artery stenting (CAS) has been indicated as an alternative to carotid endarterectomy in high risk patients. Sometimes, an aortic arch can be anatomically unfavourable for CAS. Herein we report our experience in a case of CAS with transcervical approach. Presentation of case A 77-year-old male was referred to our hospital for severe subtotal occlusion of the left internal carotid artery. He had a past medical history of radiation to the head and neck for laryngeal cancer. Previous CT-angiography had shown a type III aortic with bovine arch. CAS via transcervical approach was performed with transitory reversal flow during the placement of RX Spider Filter 6 Fr (Medtronic,…

Aortic archmedicine.medical_specialtymedicine.diagnostic_testbusiness.industrymedicine.medical_treatmentBalloon catheterTranscervical approachCarotid endarterectomySettore MED/22 - Chirurgia VascolareSurgerymedicine.arteryOcclusionAngiographyCase reportmedicinecardiovascular systemSurgeryCommon carotid arteryReversal flowbusinessInternal jugular veinShunt (electrical)Carotid artery stenting
researchProduct

Echocardiographic and angiographic evaluation of left ventricular function during percutaneous transluminal aortic valvuloplasty.

1992

Transesophageal echocardiography was used to study the effect of the balloon inflation on left ventricular function in 20 patients with critical aortic stenosis undergoing balloon valvuloplasty. Balloon inflation caused an increase of end-diastolic (15% to 34%) and end-systolic (57% to 72%) left ventricular volume. Left ventricular wall stress increased from 30 +/- 10 x 10(3) dyn/cm2 at diastole and 121 +/- 40 x 10(3) dyn/cm2 at systole to 44 +/- 11 x 10(3) dyn/cm2 and 191 +/- 55 x 10(3) dyn/cm2, respectively, when the balloon was inflated (P less than 0.05). Turbulent regurgitant jet across the mitral valve increased from 15 +/- 2% to 25 +/- 3% during balloon inflation (P less than 0.01). …

Aortic valveMalemedicine.medical_specialtymedicine.medical_treatmentDiastoleMyocardial InfarctionBalloonCoronary AngiographyVentricular Function LeftCatheterizationRisk FactorsMitral valveInternal medicineCoronary CirculationmedicineHumansSystoleCardiac OutputAgedAged 80 and overbusiness.industryHemodynamicsMitral Valve InsufficiencyBlood flowAortic Valve StenosisMiddle Agedmedicine.diseaseAortic valvuloplastyStenosismedicine.anatomical_structureEchocardiographyAortic Valvecardiovascular systemCardiologyFemaleCardiology and Cardiovascular MedicinebusinessCatheterization and cardiovascular diagnosis
researchProduct

Modified hemi-Fontan procedure on the beating heart

1998

the heart by infusing the cardioplegic solution under aortic occlusion by means of the balloon throughout the procedure. Even though the balloon catheter passes through the aortic valve, significant aortic valve insufficiency is not likely to occur because of the small caliber of the balloon catheter. We believe that the clinical application of this double-lumen aortic occlusion catheter will protect the myocardium in patients with a thoracoabdominal aortic aneurysm or distal descending aortic aneurysm who undergo the operation through the left thoracotomy with DHCA.

Aortic valvePulmonary and Respiratory Medicinemedicine.medical_specialtyBeating heartmedicine.medical_treatmentFontan ProcedureBalloonAortic aneurysmHemi-Fontan ProcedureInternal medicineHypoplastic Left Heart SyndromemedicineHumansThoracotomyCardiopulmonary Bypassbusiness.industryAnastomosis SurgicalBalloon catheterInfantmedicine.diseaseSurgeryCathetermedicine.anatomical_structurecardiovascular systemCardiologySurgerybusinessCardiology and Cardiovascular MedicineThe Journal of Thoracic and Cardiovascular Surgery
researchProduct

Assessment of left ventricular function during aortic balloon valvuloplasty by transesophageal echocardiography

1989

Several reports have documented the feasability and utility of balloon aortic valvuloplasty as a palliative treatment for high-surgical-risk patients with critical aortic valve stenosis (1–3).

Aortic valvemedicine.medical_specialtyMitral regurgitationVentricular functionPalliative treatmentbusiness.industrymedicine.medical_treatmentmedicine.diseaseBalloon valvuloplastyBalloonAortic valvuloplastymedicine.anatomical_structureAortic valve stenosisInternal medicinecardiovascular systemmedicineCardiologybusiness
researchProduct

We are Still Learning from Death: After CPR, Balloon Expanding Valve (Intuity Aortic Valve) Revealed to be in Position

2021

Patients with high predicated risk undergo TAVI as an alternative treatment to surgical valve replacement...

Aortic valvemedicine.medical_specialtybusiness.industrymedicine.medical_treatmentIschemiaGeneral Medicine030204 cardiovascular system & hematologymedicine.diseaseBalloonAlternative treatmentSurgery03 medical and health sciencesPosition (obstetrics)0302 clinical medicinemedicine.anatomical_structureSkull fractureValve replacementmedicine030212 general & internal medicinebusinessBiomedical Journal of Scientific & Technical Research
researchProduct

High-frequency rotational ablation following failed percutaneous transluminal coronary angioplasty.

1994

Percutaneous transluminal coronary angioplasty (PTCA) failed in 29 of 1,150 patients (2.5%) after successful passage of the guide wire. The reasons for failure were inability to pass the lesion with a balloon in 28 patients and inability to dilate the lesion in 1 patient. In these patients (15 stenoses and 14 chronic occlusions) rotational ablation was performed. We were able to pass the burr through the lesion in all of them, resulting in a reduction of diameter stenosis from 87 +/- 15 to 51 +/- 18%. Rotational ablation alone was initially successful (stenoses reduction > 20% and residual stenoses < 50%) in 15 of 29 (52%) patients. Additional PTCA was performed in 21 of 29 (72%) patients, …

Atherectomy CoronaryMalemedicine.medical_specialtyPercutaneous transluminal coronary angioplastyRotational ablationCoronary Artery DiseaseBalloonCoronary AngiographyLesionRecurrenceInternal medicinemedicineHumansMajor complicationTreatment FailureAngioplasty Balloon Coronarybusiness.industryMiddle AgedCoronary heart diseaseSurgeryDiameter stenosisCardiologyFemalemedicine.symptomCardiology and Cardiovascular MedicinebusinessCatheterization and cardiovascular diagnosis
researchProduct