Search results for "binocular"
showing 10 items of 89 documents
Changes in physiological astigmatism of human eye during accommodation in emmetropes (Conference Presentation)
2017
Introduction: Most young emmetrope eyes are far from ideal and have some degree of minor spherocylindrical error including also physiological astigmatism. Because of the changes in the shape of optical interfaces, pupil size, eyelid pressure, tear film, body posture, binocularity and accommodation astigmatism is considered as constantly dynamic phenomenon (Cheng et al, 2004). The purpose of this study was to evaluate and quantify changes in physiological astigmatism during accommodation. Method: Twenty young emmetropes with mean age 24 ± 4 years were selected for the study. Refraction and accommodative response were measured monocularly for dominant eye with an open-field infrared autorefract…
Proposal of a new diffractive corneal inlay to improve near vision in a presbyopic eye
2020
[EN] A new class of diffraction-based corneal inlays for treatment of presbyopia is described. The inlay is intended to achieve an improvement of the near focus quality over previous designs. Our proposal is a two-zone hybrid device with separated amplitude and phase areas having a central aperture and no refractive power. An array of micro-holes is distributed on the surface of the inlay conforming a binary photon sieve. In this way, the central hole of the disk contributes to the zero order of diffraction, and the light diffracted by the micro-holes in the peripheral photon sieve produces a real focus for near vision. We employed ray-tracing software to study the performance of the new in…
iLocater: a diffraction-limited Doppler spectrometer for the Large Binocular Telescope
2016
We are developing a stable and precise spectrograph for the Large Binocular Telescope (LBT) named "iLocater." The instrument comprises three principal components: a cross-dispersed echelle spectrograph that operates in the YJ-bands (0.97-1.30 microns), a fiber-injection acquisition camera system, and a wavelength calibration unit. iLocater will deliver high spectral resolution (R~150,000-240,000) measurements that permit novel studies of stellar and substellar objects in the solar neighborhood including extrasolar planets. Unlike previous planet-finding instruments, which are seeing-limited, iLocater operates at the diffraction limit and uses single mode fibers to eliminate the effects of m…
Binocular motility system and temporomandibular joint internal derangement: A study in adults
2007
Abstract INTRODUCTION: Ocular convergence defects have been confirmed in adults with temporomandibular joint (TMJ) dysfunction, but few studies of the relationship of the oculomotor apparatus to TMJ disc displacement have been reported. The purpose of this study was to examine the impact of disc displacement on the oculomotor capacity of the eyes in adults. METHODS: Fifty symptomatic patients with bilateral TMJ disc displacement (13 men, 37 women; mean age, 28.84 +/- 8.22 years; range, 18-40 years) were compared with the same number of asymptomatic volunteers with normal disc position (14 men, 36 women; mean age, 29.96 +/- 5.04 years; range, 18-37 years). All subjects underwent standardized…
Working-Age Cataract Patients: Visual Results, Reading Performance, and Quality of Life with Three Diffractive Multifocal Intraocular Lenses
2013
Purpose To compare the visual outcomes, reading performance, and quality of life (QoL) of working-age cataractous patients bilaterally implanted with 3 different diffractive multifocal intraocular lenses (MIOLs). Design Two-center, randomized, prospective, double-masked study. Participants Sixty-three consecutive patients (126 eyes) seen at Ophthalmology Section, Palermo and Florence University, Italy, randomized to receive the ReSTOR SN6AD3 (Alcon Laboratories, Inc, Irvine, CA) (20 patients, group A), ReSTOR SN6AD1 (Alcon Laboratories, Inc) (21 patients, group B), or TECNIS ZMA00 (Abbott Medical Optics, Santa Ana, CA) (22 patients, group C) MIOL. Intervention Phacoemulsification. Main Outc…
Visual and Refractive Outcomes in Hyperopic Pseudophakic Patients Implanted with the Acri.LISA 366D Multifocal Intraocular Lens
2009
Our purpose was to assess the visual quality after bilateral implantation of the Acri.LISA 366D intraocular lens (IOL; Carl Zeiss Meditec, Jena, Germany) in patients with hyperopia. We did a prospective and nonrandomized study. One hundred and seventy eyes of 85 patients had bilateral implantation of the Acri.LISA 366D IOL. The patients were divided into 2 groups: low to moderate hyperopia (IOL power, 21 to 24.5 diopters [D]) and high hyperopia (IOL power, 25 to 36 D). Monocular and binocular best spectacle-corrected visual acuity (BSCVA), best distance-corrected near visual acuity (BCNVA), binocular best distance-corrected intermediate visual acuity (VA), and distance contrast sensitivity …
Stereoacuity with balanced presbyopic contact lenses.
2010
Our aim was to evaluate near stereoacuity with the balanced Proclear Multifocal simultaneous vision contact lens. Twenty-five presbyopic subjects were fitted binocularly with the Proclear Multifocal contact lens and with distance contact lenses combined with reading spectacles, which served as controls. After one month, stereoacuity was measured using the vectographic Titmus and Random dot stereotests and the Howard-Dolman (HD) apparatus under photopic conditions (85 cd/m(2) ) at 40 cm. Binocular high-contrast visual acuities (BHCVA) at distance and near were examined. For the multifocal group, mean stereoacuity with the Howard-Dolman method was 22.40 ± 8.23 seconds of arc. Using the Titmus…
Visual performance comparison between contact lens-based pinhole and simultaneous vision contact lenses.
2011
Background The aim was to evaluate the visual performance provided with a contact lens-based pinhole design against a simultaneous vision multifocal contact lens. Methods In a cross-over study at the University of Valencia, 22 presbyopic patients were evaluated using an artificial pupil fitted on the non-dominant eye and the simultaneous vision PureVision Multifocal contact lenses. After one month of contact lens wear, binocular distance visual acuity (BDVA), binocular near visual acuity (BNVA), defocus curve, binocular distance contrast sensitivity, binocular near contrast sensitivity, and stereoacuity were measured, under photopic conditions (85 cd/m2). In addition, binocular distance vis…
Bilateral implantation of the Acri.LISA bifocal intraocular lens in myopic eyes.
2009
Purpose To asses visual quality after bilateral implantation of the Acri.LISA 366D intraocular lens (IOL) (Carl Zeiss Meditec) in patients with high and low–moderate myopia. Methods A total of 304 eyes of 152 patients had bilateral implantation of the Acri.LISA 366D IOL. The patients were divided into 2 groups: low–moderate myopia (IOL power from 15 to 20.5 D) and high myopia (IOL power from 0 to 14.5 D). Monocular and binocular best-corrected distance visual acuity (BCVA) and best distance-corrected near visual acuity (BCNVA), binocular best distance-corrected intermediate visual acuity (BCIVA), and distance contrast sensitivity (OS) under photopic (85 cd/m2) and mesopic (5 cd/m2) conditio…
Visual and optical performance with the ReZoom multifocal intraocular lens
2011
Purpose This study evaluated visual acuity, contrast sensitivity, and wavefront aberrations after refractive multifocal intraocular lens (IOL) implantation. Methods A prospective study comprising 174 eyes of 87 patients who had bilateral implantation of a multifocal IOL was carried out. A control group of 100 eyes of 50 age-matched patients with a monofocal IOL was used for comparison. Uncorrected and corrected distance and near visual acuity, contrast sensitivity (CS), and wavefront analysis (Hartmann-Shack) was performed 6 months after surgery. Contrast sensitivity was tested for distance and near under mesopic (2 cd/m2) and photopic conditions (90 cd/m2). Results Distance photopic CS was…