Search results for "blood vessel"

showing 10 items of 323 documents

Infrapopliteal Composite Bypass with Autologous Vein and Second Generation Glutaraldehyde Stabilized Human Umbilical Vein (HUV) for Critical Lower Li…

2007

Objective. To audit a single center consecutive series of infrapopliteal composite bypasses with second generation glutaraldehyde stabilized human umbilical vein. Design. Retrospective study. Patients. From January 1996 to July 2006 89 femoro-distal bypasses were constructed in 85 patients with HUV and residual vein segments as composite grafts in the absence of sufficient length of autologous vein. Methods. All patients with infrainguinal bypass operations were registered prospectively. Bypasses to infrapopliteal arteries performed with HUV-composite grafts were reviewed for graft patency, limb salvage, patient survival and possible biodegeneration of the HUV. Results. Early graft thrombos…

MaleReoperationmedicine.medical_specialtyUmbilical VeinsComorbiditySingle CenterUmbilical veinDuplex scanningBlood vessel prosthesisIschemiaLimb salvageAutologous veinVascular PatencyMedicineHumansVeinVascular PatencyAgedRetrospective StudiesMedicine(all)Aged 80 and overBioprosthesisLegbusiness.industryAnastomosis SurgicalGraft Occlusion VascularRetrospective cohort studyFemoral VeinMiddle AgedSurgeryBlood Vessel Prosthesismedicine.anatomical_structureFemaleSurgerybusinessCardiology and Cardiovascular MedicineHumanJournal of Vascular Surgery
researchProduct

Kinetic and static perimetry after 16 years and additional OCT-A analysis in eyes with long-lasting optic disc drusen

2021

The aim of the study is to evaluate the progression of visual field (VF) defects over 16 years of observation and to assess abnormalities in vessels and retinal nerve fibre layer (RNFL) thickness in patients with optic disc drusen (ODD). Both static automated perimetry (SAP) and semi-automated kinetic perimetry (SKP) were performed in 16 eyes of 8 patients (mean age 54 years) with ODD among 26 eyes of 13 patients examined 16 years before. The area of I2e, I4e, III4e, and V4e isopters was measured in deg2. The MD and PSD parameters were estimated using SAP. Optical coherence tomography angiography (OCT-A) was additionally performed in 16 ODD eyes and 16 eyes of 8 healthy subjects to estimate…

MaleRetinal Ganglion CellsFovea Centralisgenetic structureschemistry.chemical_compoundNerve FibersAnimal CellsMedicine and Health SciencesMacula LuteaProspective StudiesNeuronsMultidisciplinaryStatistical ModelsOptic Disk DrusenStatisticsQAngiographyRMiddle AgedOptic disc drusenVisual fieldmedicine.anatomical_structurePhysical SciencesOptic nerveMedicineFemaleAnatomyCellular TypesTomography Optical CoherenceOptic discResearch ArticleLong lastingAdultmedicine.medical_specialtyOcular AnatomyScienceOptic DiskVision DisordersOptic DiscYoung AdultOcular SystemOphthalmologymedicineHumansAgedPlexusbusiness.industryFovea centralisBiology and Life SciencesRetinal VesselsRetinalOptic NerveCell Biologymedicine.diseaseeye diseasesCapillariesOphthalmologychemistryCellular NeuroscienceCase-Control StudiesCardiovascular AnatomyEyesBlood VesselsVisual Field Testssense organsVisual FieldsbusinessHeadMathematicsNeuroscience
researchProduct

Different methods for anatomical targeting.

2003

AIM: Several procedures are used in the different neurosurgical centers in order to perform stereotactic surgery for movement disorders. At the moment no procedure can really be considered superior to the other. We contribute with our experience of targeting method. METHODS: Ten patients were selected, in accordance to the guidelines for the treatment of Parkinson disease, and operated by several methods including pallidotomy, bilateral insertion of chronic deep brain electrodes within the internal pallidum and in the subthalamic nucleus (18 procedures). Interventions: in each patient an MR scan was performed the day before surgery. Scans were performed axially parallel to the intercommissu…

MaleSettore MED/27 - NeurochirurgiaParkinson DiseaseMiddle AgedGlobus PallidusMagnetic Resonance ImagingNeurosurgical ProceduresCerebral AngiographyStereotaxic TechniquesSurgery Computer-AssistedDBS movement disorders stereotactic neurosurgerySubthalamic NucleusCerebrovascular CirculationBlood VesselsHumansFemaleTomography X-Ray ComputedAgedJournal of neurosurgical sciences
researchProduct

Migration of Neuronal Precursors From the Telencephalic Ventricular Zone Into the Olfactory Bulb in Adult Zebrafish

2011

In the brain of adult mammals, neuronal precursors are generated in the subventricular zone in the lateral wall of the lateral ventricles and migrate into the olfactory bulbs (OBs) through a well-studied route called the rostral migratory stream (RMS). Recent studies have revealed that a comparable neural stem cell niche is widely conserved at the ventricular wall of adult vertebrates. However, little is known about the migration route of neuronal precursors in nonmammalian adult brains. Here, we show that, in the adult zebrafish, a cluster of neuronal precursors generated in the telencephalic ventricular zone migrates into the OB via a route equivalent to the mammalian RMS. Unlike the mamm…

MaleTelencephalonRostral migratory streamNeurogenesisSubventricular zoneBiologyAnimals Genetically Modifiedblood vesselsLateral ventriclesrostral migratory streamventricular zoneCell MovementLateral VentriclesmedicineAnimalsZebrafishZebrafishNeuronsneuronal migrationCerebrumStem CellsGeneral NeuroscienceNeurogenesisfungiAge Factorsbiology.organism_classificationzebrafishOlfactory BulbNeural stem cellOlfactory bulbadult neurogenesismedicine.anatomical_structurenervous systemFemaleNeuroscience
researchProduct

A multicenter 12-month experience with a new iliac side-branched device for revascularization of hypogastric arteries.

2016

Abstract Objective The aim of this study was to investigate the 1-year safety and efficacy of a new iliac side-branched device (IBD) for revascularization of the hypogastric arteries. Methods Patients receiving the E-liac (Jotec GmbH, Hechingen, Germany) side-branched device at six German vascular centers either as a stand-alone procedure or in combination with abdominal aortic aneurysm exclusion were included in a prospectively created data bank. Collected data were analyzed for baseline characteristics, procedural events, and clinical follow-up; variables included endoleaks, reinterventions, and internal iliac artery (IIA) patency. Results Between January 2012 and January 2015, a total of…

MaleTime FactorsDatabases FactualEndoleakComputed Tomography Angiographymedicine.medical_treatmentBlood Loss Surgical030204 cardiovascular system & hematologyEndovascular aneurysm repair030218 nuclear medicine & medical imaging0302 clinical medicineRisk FactorsGermanyMedicineHospital MortalityAged 80 and overEndovascular ProceduresGraft Occlusion VascularArteriesMiddle AgedCommon iliac arteryInternal iliac arteryAbdominal aortic aneurysmTreatment OutcomeIliac AneurysmFemaleStentsRadiologyCardiology and Cardiovascular Medicinemedicine.medical_specialtyRevascularizationProsthesis DesignPelvis03 medical and health sciencesBlood Vessel Prosthesis ImplantationAneurysmBlood vessel prosthesismedicine.arteryHumansVascular PatencyAgedRetrospective Studiesbusiness.industryExternal iliac arteryAngiography Digital Subtractionmedicine.diseaseSurgeryBlood Vessel ProsthesisFeasibility StudiesSurgerybusinessJournal of vascular surgery
researchProduct

A 15-Year Single-Center Experience of Endovascular Repair for Elective and Ruptured Abdominal Aortic Aneurysms

2016

Purpose: To evaluate the differences in technical outcomes and secondary interventions between elective endovascular aneurysm repair (el-EVAR) procedures and those for ruptured aneurysms (r-EVAR). Methods: Of the 906 patients treated with primary EVAR from September 1998 until July 2012, 43 cases were excluded owing to the use of first-generation stent-grafts. Among the remaining 863 patients, 773 (89.6%) patients (mean age 72 years; 697 men) with asymptomatic or symptomatic abdominal aortic aneurysms (AAAs) were assigned to the el-EVAR group; 90 (10.4%) patients (mean age 73 years; 73 men) were assigned to the r-EVAR group based on blood outside the aortic wall on preoperative imaging. Th…

MaleTime FactorsDatabases Factualmedicine.medical_treatmentKaplan-Meier Estimate030204 cardiovascular system & hematologySingle CenterEndovascular aneurysm repairendovascular aneurysm repairPostoperative Complications0302 clinical medicineRisk Factors030212 general & internal medicineNetherlandsAged 80 and overmedicine.diagnostic_testruptured aneurysmEndovascular ProceduresMiddle AgedAbdominal aortic aneurysmTreatment OutcomeElective Surgical ProceduresreinterventionsFemaleStentsmedicine.symptomCardiology and Cardiovascular Medicinemedicine.medical_specialtyAortographycomplicationsAortic RuptureendoleakProsthesis DesignAortographyAsymptomaticDisease-Free SurvivalBlood Vessel Prosthesis Implantation03 medical and health sciencesabdominal aortic aneurysmBlood vessel prosthesismedicineHumansRadiology Nuclear Medicine and imagingAortic ruptureAgedRetrospective Studiesstent-graftbusiness.industryRetrospective cohort studymedicine.diseaseBlood Vessel ProsthesisSurgerySurgeryEmergenciesbusinessAortic Aneurysm AbdominalJournal of Endovascular Therapy
researchProduct

Long-term results of simplified frozen elephant trunk technique in complicated acute type A aortic dissection: A case-control study.

2016

Aim To describe the long-term experience of a simplified frozen elephant trunk technique (sFETT) used in complicated acute type A aortic dissection (AAAD) treatment. Methods and results Between January 2001 and December 2012, 34 patients (mean age 59.9 ± 11.0 years) with complicated AAAD (DeBakey I) underwent an emergency surgery including sFETT. sFETT consisted in gluing the dissected aortic arch wall layers with gelatine-resorcinol adhesive and video-assisted antegrade open arch aortic stent-graft deployment in the arch or proximal descending aorta. In addition to sFETT, the aortic root was addressed with standard techniques. A 30-day mortality was 14.7% (five patients) due to bleeding (1…

MaleTime FactorsElephant trunksComputed Tomography AngiographyVideo-Assisted SurgeryKaplan-Meier Estimate030204 cardiovascular system & hematologyComplicated acute type A aortic dissectionSettore MED/22 - Chirurgia VascolareAortic aneurysm0302 clinical medicinePostoperative ComplicationsRisk Factorsfrozen elephant trunkComputed tomography angiographyAortic dissectionAged 80 and overmedicine.diagnostic_testMedicine (all)Endovascular ProceduresGeneral MedicineMiddle AgedAortic AneurysmTreatment OutcomeAcute typeAcute DiseaseFemaleStentsCardiology and Cardiovascular MedicineAdultReoperationmedicine.medical_specialtyAortographyProsthesis DesignAortography03 medical and health sciencesBlood Vessel Prosthesis ImplantationBlood vessel prosthesismedicineHumansRadiology Nuclear Medicine and imagingAgedRetrospective StudiesComplicated acute type A aortic dissection; frozen elephant trunk; Surgery; Medicine (all); Radiology Nuclear Medicine and Imaging; Cardiology and Cardiovascular Medicinebusiness.industryLong term resultsmedicine.diseaseSurgeryBlood Vessel ProsthesisAortic Dissection030228 respiratory systemSurgeryTissue AdhesivesEmergenciesbusinessVascular
researchProduct

Mid-term Results of Chimney and Periscope Grafts in Supra-aortic Branches in High Risk Patients

2017

Purpose Report mid-term outcomes of thoracic endovascular aneurysm repair (TEVAR) with chimney and periscope grafts (CPG) in supra-aortic branches (SAB). Methods Retrospective analysis, from October 2009 to May 2014, of patients with aneurysms requiring TEVAR with zone 0/1/2 proximal landing in association with at least one CPG in the SAB. All patients were considered at high risk for conventional surgery. Peri-operative mortality and morbidity, retrograde type A dissection, maximum aortic transverse diameter (TD) and its post-operative evolution, endoleak, survival, freedom from cardiovascular re-interventions, and CPG freedom from occlusion during the follow-up were analysed. Results Fort…

MaleTime FactorsEndoleakComputed Tomography Angiographymedicine.medical_treatmentMid term resultsKaplan-Meier Estimate030204 cardiovascular system & hematologySettore MED/22 - Chirurgia VascolareEndovascular aneurysm repairAortic aneurysmPostoperative Complications0302 clinical medicineRisk FactorsOcclusionMedicine030212 general & internal medicineAortic arch aneurysm; Chimney graft/technique; Endoleak; Endovascular aneurysm repair; Parallel graft; Periscope graft; Surgery; Cardiology and Cardiovascular MedicineAged 80 and overeducation.field_of_studyHigh risk patients10042 Clinic for Diagnostic and Interventional RadiologyEndovascular ProceduresMiddle Aged2746 SurgeryTreatment Outcomecardiovascular systemFemaleRadiologyCardiology and Cardiovascular MedicineAdultmedicine.medical_specialtyPopulation610 Medicine & healthProsthesis DesignAortographyRisk AssessmentDisease-Free Survival2705 Cardiology and Cardiovascular MedicineBlood Vessel Prosthesis ImplantationEndovascular aneurysm repair03 medical and health sciencesAneurysmmedicine.arteryHumanseducationAgedRetrospective StudiesAortaAortic Aneurysm ThoracicParallel graftAortic arch aneurysmbusiness.industryPatient SelectionChimney graft/techniquemedicine.diseaseBlood Vessel Prosthesis10020 Clinic for Cardiac SurgerySurgeryPeriscope graftSurgerybusinessEuropean Journal of Vascular and Endovascular Surgery
researchProduct

Hybrid Endograft Solution for Complex Iliac Anatomy

2010

The purpose of this study was to evaluate single-center results with selective use of Gore Excluder limbs (W.L. Gore & Associates, Flagstaff, AZ) in a Cook Zenith body (Cook Inc, Bloomington, IN) for elective endovascular abdominal aortic aneurysm (AAA) repair. A prospectively held database for patients with AAA, who were treated endovascularly between March 1999 and July 2008, was queried for patients treated with a Cook Zenith body and one or two Gore Excluder limbs. Indication, technical success, late limb occlusion, and disconnection were evaluated. From 276 patients who were treated with a Zenith body, 29 underwent repair with hybrid graft components with, in total, 41 Gore Exclud…

MaleTime FactorsOCCLUSIONmedicine.medical_treatmentSettore MED/22 - Chirurgia VascolareEndovascular aneurysm repairendovascular aneurysm repairAortic aneurysmOcclusionEVARAged 80 and overOUTCOMESmedicine.diagnostic_testGeneral MedicineAnatomyAbdominal aortic aneurysmTreatment OutcomeElective Surgical ProceduresFemaleRadiologyCardiology and Cardiovascular MedicineElective Surgical Proceduremedicine.medical_specialtyAortographyProsthesis DesignAortographyIliac ArteryBlood Vessel Prosthesis Implantationabdominal aortic aneurysm endovascular aneurysm repair Excluder limbs hybrid graft iliac tortuosityabdominal aortic aneurysmBlood vessel prosthesismedicineHumansExcluder limbsRadiology Nuclear Medicine and imagingAgedRetrospective Studiesbusiness.industryENDOVASCULAR REPAIRAORTIC-ANEURYSM REPAIRmedicine.diseaseSurgeryBlood Vessel Prosthesisiliac tortuosityFeasibility StudiesSurgeryhybrid graftSTENT-GRAFTSbusinessTomography X-Ray ComputedAbdominal surgeryAortic Aneurysm AbdominalVascular
researchProduct

Peroperative Intravascular Ultrasound for Endovascular Aneurysm Repair versus Peroperative Angiography: A Pilot Study in Fit Patients with Favorable …

2020

The aim of this study was to compare intravascular ultrasound (IVUS) assistance for endovascular aortic aneurysm repair (EVAR) to standard assistance by angiography.From June 2015 to June 2017, 173 consecutive patients underwent EVAR. In this group, 69 procedures were IVUS-assisted with X-ray exposure limited to completion angiography for safety purposes because an IVUS probe does not yet incorporate a duplex probe (group A), and 104 were angiography-assisted procedures (group B). All IVUS-assisted procedures were performed by vascular surgeons with basic duplex ultrasound (DUS) training. The primary study endpoints were mean radiation dose, duration of fluoroscopy, amount of contrast media…

MaleTime FactorsRadiographymedicine.medical_treatmentContrast MediaPilot Projects030204 cardiovascular system & hematologyRadiography InterventionalEndovascular aneurysm repair030218 nuclear medicine & medical imagingEndovascular aortic repairAortic aneurysmPostoperative Complications0302 clinical medicineRisk FactorsIntravascular ultrasoundAortic aneurysm endovascular repair intravascular ultrasoundFluoroscopyAged 80 and overmedicine.diagnostic_testEndovascular ProceduresAngiographyGeneral MedicineMiddle AgedRadiation ExposureTreatment Outcomesurgical procedures operativecardiovascular systemendovascularFemaleRadiologyCardiology and Cardiovascular MedicineAdultmedicine.medical_specialtyAortographyOperative TimeRadiation DosageAortographyintravascular ultrasoundBlood Vessel Prosthesis Implantation03 medical and health sciencesText miningabdominal aortic aneurysmPredictive Value of TestsmedicineHumanscardiovascular diseasesUltrasonography InterventionalAgedRetrospective StudiesIVUSbusiness.industrymedicine.diseaseAngiographySurgerybusinessAortic Aneurysm AbdominalAbdominal surgeryAnnals of Vascular Surgery
researchProduct