Search results for "bromi"
showing 10 items of 777 documents
Templated growth of smart coatings: Hybrid chemical vapour deposition of vanadyl acetylacetonate with tetraoctyl ammonium bromide
2009
Hybrid aerosol assisted and atmospheric pressure chemical vapour deposition methodology has been utilised to produce thin films of vanadium dioxide from vanadyl acetylacetonate. Tetraoctyl ammonium bromide (TOAB) was used in the aerosol precursor solution. The films were analysed by X-ray diffraction, scanning electron microscopy (SEM) and X-ray photoelectron spectroscopy. Their optical and thermochromic behaviour was also determined. It was found that the use of TOAB had a templating effect that led to a halving in the particle size and that this consequently led to a significant decrease in the thermochromic transition temperature of the films to 34 8C.
Templated growth of smart nanocomposite thin films: Hybrid aerosol assisted and atmospheric pressure chemical vapour deposition of vanadyl acetylacet…
2009
Hybrid aerosol assisted and atmospheric pressure chemical vapour deposition methodology has been utilised to produce nanocomposite thin films of gold nanoparticles and vanadium dioxide from vanadyl acetylacetonate and auric acid. The addition of tetraoctyl ammonium bromide (TOAB) to the precursor Solution gave control of the size and distribution of gold nanoparticles in the vanadium oxide matrix. These reactions led to vanadium dioxide films with reduced crystallite sizes and enhanced thermochromic properties. The films were analysed by X-ray diffraction, scanning electron microscopy and X-ray photoelectron spectroscopy. Their optical and thermochromic behaviour was also determined, This h…
A Quantitative Estimate of Ascorbic and Isoascorbic Acid by High Performance Liquid Chromatography: Application to Citric Juices
1993
Abstract The present report deals with the optimization and verification of a simple HPLC isocratic method useful for determining ascorbic and isoascorbic acids in standard solutions and fruit juices. Sample preparation is minimal and docs not require derivatization. The method uses an octadecyl reversed phase, a mobile phase which contains cetyltrimethyl ammonium bromide 0.05M as the ionic pair and potassium dihydrogen phosphate as a buffer, at pH=4.5, and 4-hydro-xyacetanilide as internal standard. The proposed method makes it possible to quantify ascorbic and isoascorbic acid in less than 13 minutes, with precision (C. V. 3.5%) and accuracy (recover' of 98%).
Analytical capabilities of high performance liquid chromatography – Atmospheric pressure photoionization – Orbitrap mass spectrometry (HPLC-APPI-Orbi…
2015
A new analytical method was established and validated for the analysis of 27 brominated flame retardants (BFRs), including so called "emerging" and "novel" BFRs (EBFRs and NBFRs) in fish samples. High performance liquid chromatography (HPLC) coupled to Orbitrap mass spectrometry (Orbitrap-MS) employing atmospheric pressure photoionization (APPI) interface operated in negative mode was used for the identification/quantitation of contaminants. HPLC-Orbitrap-MS analysis provided a fast separation of selected analytes within 14 min, thus demonstrating a high throughput processing of samples. The developed methodology was tested by intralaboratory validation in terms of recovery, repeatability, …
In-tube solid-phase microextraction-capillary liquid chromatography as a solution for the screening analysis of organophosphorus pesticides in untrea…
2006
This paper describes a method for the selective screening of organophosphorus pesticides in water. In-tube solid-phase microextraction (SPME) in an open capillary column coupled to capillary liquid chromatography (LC) with UV detection has been used to effect preconcentration, separation and detection of the analytes in the same assembly. For in-tube SPME two capillary columns of the same length and different internal diameters and coating thicknesses have been tested and compared, a 30 cm x 0.25 mm I.D., 0.25 micro m thickness coating column, and a 30 cm x 0.1 mm I.D., 0.1 micro m of coating thickness column. In both columns the coating was 95% dimethylpolysiloxane (PDMS)-5% diphenylpolysi…
Preconcentration of aluminium by micellar-enhanced ultrafiltration
1993
Abstract Traces of aluminium were preconcentrated in water samples by forming a complex with lumogallion, and successfully accumulated in the micellar phase obtained from cationic or non-ionic surfactants and filtered through 10 000 molecular weight cut-off ultrafiltration membranes. Studies indicated that, at pH 5.9, with 1 X 10 −3 M lumogallion and 2 X 10 −2 M cetyltrimethylamonium bromide, quantitative retention of aluminium present at μg ml −1 concentration levels was achieved. A micellar-enhanced fluorimetric procedure was employed to analyse the permeate solutions, whereas nitrous oxide-acetylene flame atomic emission spectrometry was used to determine aluminium in the retentate. The …
Multi-analyte method for the analysis of legacy and alternative brominated and chlorinated flame retardants in food products of animal origin using g…
2019
Abstract An analytical method was developed and validated for the analysis of 32 halogenated flame retardants (HFRs), including 13 polybrominated diphenyl ethers (PBDEs), 9 dechlorane-related compounds (DRCs) and 10 of the so-called alternative BFRs in food samples of animal origin. Gas chromatography (GC) coupled with magnetic sector high resolution mass spectrometry (HRMS) was used for the instrumental analysis. Intralaboratory validation of the developed method was performed in terms of recovery, repeatability, linear calibration ranges, instrumental and method limits of quantitation (i-LOQ and m-LOQ). Where possible, trueness was verified by the analysis of reference materials (RMs). Fo…
Comparison between micellar liquid chromatography and capillary zone electrophoresis for the determination of hydrophobic basic drugs in pharmaceutic…
2007
[EN] The determination of highly hydrophobic basic compounds by means of conventional reversed-phase liquid chromatographic methods has several drawbacks. Owing to the characteristics of micellar liquid chromatography (MLC) and capillary electrophoresis (CE), these techniques could be advantageous alternatives to reversed-phase chromatographic methods for the determination of these kinds of compounds. The objective of this study was to develop and compare MLC and CE methods for the determination of antipsychotic basic drugs (amitryptiline, haloperidol, perphenazine and thioridazine) in pharmaceutical preparations. The chromatographic determination of the analytes was performed on a Kromasil…
Ultra high performance liquid chromatography-time-of-flight high resolution mass spectrometry in the analysis of hexabromocyclododecane diastereomers…
2014
An efficient ultra high performance liquid chromatography (UHPLC)-time-of-flight high resolution mass spectrometry (TOF-HRMS) method was elaborated for the determination of hexabromocyclododecane (HBCD) diastereomers in fish samples and compared against UHPLC-Orbitrap-HRMS and UHPLC-triple quadrupole (QqQ) tandem MS (MS/MS) techniques. The TOF-HRMS analyzer was operated at high resolution (>10000 full width at half maximum (FWHM)) with scanning the m/z range from 600 to 700, to achieve picogram quantitation limits. The effects of various operational parameters on the instrumental response were systematically investigated. Evaluation of the influence of sample clean-up procedure steps on sig…
Role of octreotide, scopolamine butylbromide, and hydration in symptom control of patients with inoperable bowel obstruction and nasogastric tubes: A…
2000
Bowel obstruction may be an inoperable complication in patients with end-stage cancer. Scopolamine butylbromide (SB) and octreotide (OCT) have been successfully used with the aim of reducing gastrointestinal (GI) secretions to avoid placement of a nasogastric tube (NGT); however, there have been no comparative studies concerning the efficacy of these drugs. Furthermore, there is little information about the role played by parenteral hydration in symptom control of these patients. In a prospective trial that involved all 17 inoperable bowel-obstructed patients presenting to our services with a decompressive NGT, patients were randomized to OCT 0.3 mg/day or SB 60 mg/day for 3 days through a …