Search results for "charge sharing"

showing 7 items of 17 documents

Digital CZT detector system for high flux energy-resolved X-ray imaging

2017

Photon counting arrays with energy resolving capabilities are recently desired for the next-generation X-ray imaging systems. In this work, we present the performance of a 2 mm thick CZT pixel detector, with pixel pitches of 500 mu m and 250 mu m, coupled to a fast and low noise ASIC (PIXIE ASIC), characterized by only the preamplifier stage. A 16-channel digital readout electronics was used to continuously digitize and process each output channel from the PIXIE ASIC, performing multi-parameter analysis (event arrival time, pulse shape, pulse height) at low and high input counting rates (ICRs). The spectroscopic response of the system to monochromatic X-ray and gamma ray sources, at both lo…

Radiology Nuclear Medicine and ImagingPhysics::Instrumentation and DetectorsPreamplifier01 natural sciences030218 nuclear medicine & medical imagingCharge sharing03 medical and health sciences0302 clinical medicineOptics0103 physical sciencesInstrumentationNuclear and High Energy PhysicPhysicsPixel010308 nuclear & particles physicsbusiness.industryDetectorSettore FIS/01 - Fisica SperimentaleGamma raySMALL PIXEL; CDTE; PERFORMANCE; RESOLUTION; PROGRESS; CTPhoton countingSettore FIS/07 - Fisica Applicata(Beni Culturali Ambientali Biol.e Medicin)Electronic Optical and Magnetic MaterialsPixieMonochromatic colorbusiness
researchProduct

Charge loss correction in CZT pixel detectors at low and high fluxes: analysis of positive and negative pulses

2018

Charge losses are typical drawbacks in cadmium–zinc–telluride (CZT) pixel detectors. The effects of these phenomena are strongly related to the interaction point of the photons and are more severe for photon interactions at the inter-pixel gap and near the pixelated anode. In this work, we present some original techniques able to correct charge losses in pixelated CZT detectors at both low and high fluxes. The height, the shape and the arrival time of collected- and induced-charge pulses with both positive and negative polarities are analysed to recover charge losses after the application of charge sharing addition (CSA). Sub-millimetre CZT pixel detectors, fabricated by different manufactu…

Settore FIS/01 - Fisica SperimentaleCZT pixel detectors Charge sharing Charge losses Charge loss correction negative induced-charge pulsesSettore FIS/07 - Fisica Applicata(Beni Culturali Ambientali Biol.e Medicin)
researchProduct

Charge Sharing and Cross Talk Effects in High-Z and Wide-Bandgap Compound Semiconductor Pixel Detectors

2023

Intense research activities have been made in the development of high-Z and wide-bandgap compound semiconductor pixel detectors for the next generation X-ray and gamma ray spectroscopic imagers. Cadmium telluride (CdTe) and cadmium-zinc-telluride (CdZnTe or CZT) pixel detectors have shown impressive performance in X-ray and gamma ray detection from energies of few keV up to 1 MeV. Charge sharing and cross-talk phenomena represent the typical drawbacks in sub-millimeter pixel detectors, with severe distortions in both energy and spatial resolution. In this chapter, we review the effects of these phenomena on the response of CZT/CdTe pixel detectors, with particular emphasis on the current st…

X-ray and gamma ray detectorsCdZnTe detectorsCompound semiconductor detectorsCross talkSpectroscopic X-ray imagingSettore FIS/01 - Fisica SperimentaleCharge sharingSettore FIS/07 - Fisica Applicata(Beni Culturali Ambientali Biol.e Medicin)CdTe detectors
researchProduct

Window-Based Energy Selecting X-ray Imaging and Charge Sharing in Cadmium Zinc Telluride Linear Array Detectors for Contaminant Detection

2023

The spectroscopic and imaging performance of energy-resolved photon counting detectors, based on new sub-millimetre boron oxide encapsulated vertical Bridgman cadmium zinc telluride linear arrays, are presented in this work. The activities are in the framework of the AVATAR X project, planning the development of X-ray scanners for contaminant detection in food industry. The detectors, characterized by high spatial (250 µm) and energy (<3 keV) resolution, allow spectral X-ray imaging with interesting image quality improvements. The effects of charge sharing and energy-resolved techniques on contrast-to-noise ratio (CNR) enhancements are investigated. The benefits of a new energy-resolved …

energy-resolved X-ray imagingcharge sharingsemiconductor pixel detectorsX-ray detectorsElectrical and Electronic EngineeringCZT detectors; charge sharing; semiconductor pixel detectors; X-ray detectors; energy-resolved X-ray imaging; contaminant detectionBiochemistryInstrumentationAtomic and Molecular Physics and Opticscontaminant detectionSettore FIS/03 - Fisica Della MateriaAnalytical ChemistryCZT detectors
researchProduct

Single Event Transients and Pulse Quenching Effects in Bandgap Reference Topologies for Space Applications

2016

An architectural performance comparison of bandgap voltage reference variants, designed in a $0.18~\mu \text {m}$ CMOS process, is performed with respect to single event transients. These are commonly induced in microelectronics in the space radiation environment. Heavy ion tests (Silicon, Krypton, Xenon) are used to explore the analog single-event transients and have revealed pulse quenching mechanisms in analogue circuits. The different topologies are compared, in terms of cross-section, pulse duration and pulse amplitude. The measured results, and the explanations behind the findings, reveal important guidelines for designing analog integrated circuits, which are intended for space appli…

mikroelektroniikkaNuclear and High Energy PhysicsBandgap voltage referencecircuit topologysingle-event transient (SET)Integrated circuit01 natural scienceslaw.inventionsingle event transientsCurrent mirrorlawpulse quenchingsingle-event effects (SEE)ionizationradiation hardening by design (RHBD)0103 physical sciencesElectronic engineeringMicroelectronicsAnalog single-event transient (ASET); bandgap voltage reference (BGR); charge sharing; CMOS analog integrated circuits; heavy ion; ionization; parasitic bipolar effect; pulse quenching; radiation effects; radiation hardening by design (RHBD); reference circuits; single-event effects (SEE); single-event transient (SET); space electronics; Voltage reference; Nuclear and High Energy Physics; Nuclear Energy and Engineering; Electrical and Electronic EngineeringAnalog single-event transient (ASET)Electrical and Electronic Engineeringparasitic bipolar effectreference voltage010302 applied physicsPhysicsbandgap voltage reference (BGR)charge sharingta114ta213010308 nuclear & particles physicsbusiness.industryanalog integrated circuitsTransistorspace electronicsPulse durationheavy ionPulse (physics)Voltage referenceNuclear Energy and EngineeringPulse-amplitude modulationreference circuitsmicroelectronicsradiation effectsspace applicationsOptoelectronicsbusinessCMOS analog integrated circuitsIEEE Transactions on Nuclear Science
researchProduct

Microscale X-ray mapping of CZT arrays: Spatial dependence of amplitude, shape and multiplicity of detector pulses

2018

In this work, we present the results of a microscale X-ray mapping of a 2 mm thick CZT pixel detector, with pixel pitches of 500 μm and 250 μm, using collimated synchrotron X-ray sources at the Diamond Light source (U. K.). The detector is dc coupled to a fast and low noise ASIC (PIXIE ASIC), characterized only by the preamplifier stage. A custom 16-channel digital readout electronics was used, able to perform online fast pulse shape and height analysis (PSHA), with low dead time and reasonable energy resolution at both low and high fluxes. The detector allows high bias voltage operation (> 5000 V/cm) and good energy resolution at room temperature (5.3 %, 2.3 % and 2.1 % FWHM at 22.1, 59…

radiation detectorRadiology Nuclear Medicine and ImagingNuclear and High Energy PhysicsMaterials sciencePreamplifier01 natural sciencesCollimated light030218 nuclear medicine & medical imagingCharge sharinglaw.invention03 medical and health sciences0302 clinical medicineOpticslaw0103 physical scienceshigh fluxmappingInstrumentation010308 nuclear & particles physicsbusiness.industryASICDetectorBiasingDead timeSynchrotronSettore FIS/07 - Fisica Applicata(Beni Culturali Ambientali Biol.e Medicin)CZTFull width at half maximumsinchrotron radiationbusiness
researchProduct

Development of 2D & 3D cadmium–zinc–telluride spectroscopic imagers for X-ray and gamma ray applications

2021

spectroscopic X-ray imagingcharge sharingcharge lossespectroscopic X-ray and gamma-ray imaging.X-ray and gamma ray detectorCdZnTe pixel detector3D CdZnTe detectorSettore FIS/07 - Fisica Applicata(Beni Culturali Ambientali Biol.e Medicin)charge-sharing correctiondrift strip detector
researchProduct