Search results for "chemical analysis"
showing 10 items of 324 documents
Cell stimulation versus cell death induced by sequential treatments with pulsed electric fields and cold atmospheric pressure plasma
2018
Pulsed electric fields (PEFs) and cold atmospheric pressure plasma (CAP) are currently both investigated for medical applications. The exposure of cells to PEFs can induce the formation of pores in cell membranes and consequently facilitate the uptake of molecules. In contrast, CAP mainly acts through reactive species that are generated in the liquid environment. The objective of this study was to determine, if PEFs combined with plasma-treated cell culture medium can mutually reinforce effects on viability of mammalian cells. Experiments were conducted with rat liver epithelial WB-F344 cells and their tumorigenic counterpart WB-ras for a direct comparison of non-tumorigenic and tumorigenic…
Saliva: Its value as a biological matrix and current methods of sampling
2006
Saliva is a non-invasive medium, its analysis is useful to measure a wide range of hormones, drugs, narcotics, antibodies, host, microbial, fungal and viral DNA up to salivary mRNA; hence, it has been suggested to be an easy and reliable biomarker in disease diagnostics, such as inflammatory mouth infections/diseases, and in normal health surveillance. In light of this potential, our primary endpoint is to review the current knowledge on saliva analyses and its recent methods of sampling.
The impact of galactooligosaccharides on the bioaccessibility of sterols in a plant sterol-enriched beverage: adaptation of the harmonized INFOGEST d…
2018
The effect of the addition of galactooligosaccharides (GOS) on sterol bioaccessibility in three plant sterol (PS)-enriched milk-based fruit beverages (without GOS addition (MfB) and with 2.5 g (MfB-G2) and 5.0 g (MfB-G5) GOS per 250 mL) was evaluated after micellar gastrointestinal digestion. Cholesterol bioaccessibility was very similar among beverages, though a slight significant increase (from 80% to 85%) was observed by the addition of 5.0 g GOS. The addition of GOS did not affect total PS bioaccessibility (≈37%). Based on the results obtained after micellar digestion, it has been demonstrated that these beverages could be a suitable food matrix for simultaneous enrichment with PS and G…
Development of a method to determine axitinib, lapatinib and afatinib in plasma by micellar liquid chromatography and validation by the European Medi…
2017
A method based on micellar liquid chromatography to quantify the tyrosine kinase inhibitors axitinib, lapatinib and afatinib in plasma is reported. The sample pretreatment was a simple 1/5-dilution in a pure micellar solution, filtration and direct injection, without requiring extraction or purification steps. The three drugs were resolved from the matrix in 17 min, using an aqueous solution of 0.07 M sodium dodecyl sulfate – 6.0% 1-pentanol, buffered at pH 7 with 0.01 M phosphate salt as mobile phase, running under isocratic mode at 1 mL/min through a C18 column. The detection was performed by absorbance at 260 nm. An accurate mathematical relationship was established between the retention…
A UHPLC-UV Method to Quantify Skin Deposition and Transdermal Permeation of Tizanidine Hydrochloride
2015
Tizanidine hydrochloride is an α2-adrenergic agonist used for the symptomatic relief of spasticity associated with multiple sclerosis or with spinal cord injury or disease. The objective of this study was to develop an isocratic, robust and sensitive ultra-high performance liquid chromatography method using UV detection for use in a project to develop a transdermal therapeutic system to deliver tizanidine across the skin. Isocratic separation was achieved using a C18 column and a mobile phase comprising a 80:20 mixture of 0.004% trifluoroacetic acid in water and MeCN (pH* 3.2) at a flow rate of 0.2 mL min(-1) Tizanidine eluted at 1.499 min and the total run time was 2 min. The method was sp…
Role of aroma–matrix interactions on perception of structured emulsions
2011
The impact of the composition of spreads on in vivo aroma release and aroma perception was investigated using online proton transfer reaction mass spectrometry (PTR-MS) and sensory methodologies. Consumption of model products spread on bread induced a significant increase in aroma release and better discrimination in aroma perception, compared to when the product was tasted pure from a spoon. Dynamic release of a series of 10 aroma compounds was slower with the increase in solid fat content, and the quantity decreased when proteins were added. Sensory ranking of model products mostly confirmed the release results.
Lanthanide–saccharide chemistry: synthesis and characterisation of Ce(III)–saccharide complexes
2000
A series of nine Ce(III) complexes has been synthesised with seven different monosaccharides (D-glucose, D-fructose, D-galactose, D-mannose, L-sorbose, D-ribose and D-xylose) and two different disaccharides (D-maltose and L-lactose), and these have been characterised with various analytical, spectral, magnetic and electrochemical techniques. The NMR studies have highlighted some interesting features about the metal-ion-binding pattern of the saccharides. Some additional coordination has been proposed along with the chelating groups in the saccharide molecules, based on the shifts in 13C NMR spectra. On the other hand, solution absorption studies and solid-state magnetic susceptibilities hav…
Dianthus superbus as a critically endangered species in Latvia: evaluation of its growth conditions and conservation possibilities
2021
Abstract Dianthus superbus is one of the most endangered species in Latvia and is on the verge of local extinction. Therefore, the aim of this study was to inventory previously identified populations of D. superbus in Latvia and to develop activities to conserve this species in accordance with the results obtained in situ. Expeditions on 18 previously documented locations, according to the data of Nature Conservation Agency, revealed only three existing D. superbus localities in Latvia with a significant number of specimens located in the Latgale region near Silenieki. In 2020, for the first time, two more new D. superbus localities were found in the vicinity of these three approved locatio…
Comparison of novel and conventional calibration techniques for the analysis of urine samples using plasma source mass spectrometry combined with a n…
2012
The accuracy and precision of the analytical data from the analysis of liquid samples with high matrix load often suffer from a compromised performance of the sample introduction system. This is especially significant in the case of miniaturized, pneumatic low flow nebulizers. Alternative low-flow sampling devices based on different operating principles are imperative to overcome this drawback. The superior performance of such an alternative liquid sample introduction system for ICP-MS, the drop-on-demand (DOD) aerosol generator based on thermal inkjet technology, was recently outlined by the same group for the analysis of aqueous standard solutions. Current improvements of the system now a…
Producing SI-traceable reference values for Cd, Cr and Pb amount contents in polyethylene samples from the Polymer Elemental Reference Material (PERM…
2000
The present paper describes the certification of the amount content of Cd, Cr and Pb in two different polyethylene materials within the third phase of the Polyethylene Elemental Reference Material (PERM) project. The analytical procedure to establish the reference values for Cd, Cr and Pb amount contents in these materials is based on isotope dilution mass spectrometry used as a primary method of measurement. Cd and Pb were measured with inductively coupled plasma-mass spectrometry and Cr with positive thermal ionization-mass spectrometry. The decomposition of the polymer matrix was carried out using a high pressure asher. Reference values for amount content, traceable to the SI-system, hav…