Search results for "chromatography"
showing 10 items of 5037 documents
Assisted baseline subtraction in complex chromatograms using the BEADS algorithm.
2017
The data processing step of complex signals in high-performance liquid chromatography may constitute a bottleneck to obtain significant information from chromatograms. Data pre-processing should be preferably done with little (or no) user supervision, for a maximal benefit and highest speed. In this work, a tool for the configuration of a state-of-the-art baseline subtraction algorithm, called BEADS (Baseline Estimation And Denoising using Sparsity) is developed and verified. A quality criterion based on the measurement of the autocorrelation level was designed to select the most suitable working parameters to obtain the best baseline. The use of a log transformation of the signal attenuate…
Optimised procedures for the reversed-phase liquid chromatographic analysis of formulations containing tricyclic antidepressants.
2003
The chromatographic behaviour (retention, selectivity, peak shape and resolution) of seven tricyclic antidepressants (TCAs), amitryptiline, clomipramine, doxepin, imipramine, maprotiline, nortryptiline and trimipramine, was examined. Conventional unendcapped Cs and C18 columns and an endcapped XTerra MS C18 column recommended for the analysis of basic compounds were used together with acetonitrile-water and micellar sodium dodecylsulfate (SDS)-pentanol mobile phases. The two best combinations were XTerra C18/acetonitrile, which yielded the largest efficiencies and resolution, and C8/SDS-pentanol, which eliminated the peak tails that were still observed with the XTerra C18 column. Both the s…
Reversed phase liquid chromatography for the enantioseparation of local anaesthetics in polysaccharide-based stationary phases. Application to biodeg…
2020
[EN] A comprehensive study on the chiral separation of bupivacaine, mepivacaine, prilocaine and propanocaine with eight commercial polysaccharide-based chiral stationary phases (CSPs) in reversed phase conditions compatible with MS detection is performed. Methanol and acetonitrile are used as organic modifiers. Retention and resolution values obtained for each compound in the different CSPs and mobile phases are compared. The polysaccharide-based CSPs tested present different enantioselectivity towards the analytes. From the results, the experimental conditions for determining the enantiomers of bupivacaine, mepivacaine, prilocaine and propanocaine in saline aqueous samples using MS detecti…
A capillary liquid chromatography method for benzalkonium chloride determination as a component or contaminant in mixtures of biocides
2015
A method for quantifying benzalkonium chloride (BAK), an alkyl dimethyl benzyl ammonium compound, in several biocides formulations is proposed. A tertiary amine like N-(3-aminopropyl)-N-dodecyl-1,3-propanediamine (TA) and a straight-chain alkyl ammonium compound like trimethyl-tetradecyl ammonium chloride (TMTDAC), have been employed as trade surfactants besides BAK. Two capillary analytical columns with different polarities are tested: inertsil CN-3 capillary column (150mm×0.5mm i.d., 3μm particle diameter) and a non endcapped Zorbax C18 capillary column (35mm×0.5mm i.d., 5μm particle diameter). This latter column provided the best separation of the BAK homologues in less than 12min using …
Sample Preparation Improvement in Polycyclic Aromatic Hydrocarbons Determination in Olive Oils by Gel Permeation Chromatography and Liquid Chromatogr…
2005
Abstract The determination of 15 polycyclic aromatic hydrocarbons (PAHs) in olive oil samples has been improved in order to obtain a fast methodology with a low limit of detection through the combination of liquid–liquid extraction with acetonitrile and preparative gel permeation chromatography (GPC) prior to the injection of purified extracts into a C18 column. Acetonitrile–water was used as the mobile phase with a gradient from 50 to 95%, w/w, acetonitrile in 30 min. The oven temperature was maintained at 15°C, and fluorometric detection was made at a fixed excitation wavelength of 264 nm and variable, optimal emission wavelength for each analyte ranging from 352 nm for 11-H-benzo(b)fluor…
Renewable polyol obtained by microwave-assisted alcoholysis of epoxidized soybean oil: Preparation, thermal properties and relaxation process
2019
[EN] The soybean oil polyol (SOP) use as feedstock in the polyurethane industry has been recently emphasized due to its excellent resistance to hydrolysis, which is also applicable in coatings and thermal insulation. In this article, the SOP was obtained by a very fast microwave-assisted alcoholysis of epoxidized soybean oil (ESO). The preparation method, thermal properties, and relaxation process were evaluated. High yields as opening and consumption epoxy group and selectivity of 99.8 mol%, 985 mol%, and 71.2 mol% were obtained. Through titrations, nuclear magnetic resonance and gel permeation chromatography were identified parameters as 0.32 mg KOH.g(-1) acid number, 190 mg KOH.g(-1) hyd…
Glycoprotein and ganglioside changes in human trophoblasts after exposure to pulsed doppler ultrasound
1995
Changes in glycoprotein and ganglioside composition in human trophoblasts (eighth week of gestation) after in vitro exposure to pulsed Doppler ultrasound (pulse duration 1.22 microseconds; repetition frequency 11.1 kHz; center frequency 4 MHz; ISPPA = 175.5 W/cm2; ISPTA = 0.59 W/cm2) were investigated. Evacuated trophoblasts were divided in two halves and insonated for 10 min on top of a 6-cm layer of 5% gelatin in 50-mL tubes (Falcon) at 37 degrees C. One half of each trophoblast was sham insonated and served as an internal control. After insonation trophoblasts were maintained at 37 degrees C for 24 h. Glycoproteins were detected using alpha-D-mannose specific lectins from Galanthus nival…
Exposure assessment of Spanish lactating mothers to acrylamide via human biomonitoring.
2021
Abstract Acrylamide (AA) is an organic compound classified as “Probably carcinogenic to humans” (Group 2 A) that can be found principally in processed carbohydrate-rich foods and tobacco smoke. In humans, after exposure, AA is rapidly metabolized and excreted in urine, predominantly as N-acetyl-S-(2-carbamoylethyl)-l-cysteine (AAMA), N-acetyl-S-(2-carbamoyl-2-hydroxyethyl)-l-cysteine (GAMA3) and N-Acetyl-3-[(3-amino-3-oxopropyl)sulfinyl]-L-alanine (AAMA-Sul), which can be used as short-term biomarkers of exposure to AA. In this study, the presence of AA metabolites in urine samples of lactating mothers living in Spain (n = 114) was analyzed by “dilute and shoot” and liquid chromatography co…
Development of a sensitive method for the determination of acrylamide in coffee using high-performance liquid chromatography coupled to a hybrid quad…
2015
The emerging trend towards high-resolution mass spectrometry (MS) alternatives was evaluated by the application of Orbitrap MS for the determination of acrylamide in coffee samples. The high resolving power of the Orbitrap MS provided the high selectivity and sensitivity that enabled quantitative analysis of acrylamide in complex matrices, such as coffee. Several sample preparation methods and scanning modes of the MS (full MS, t-SIM, t-MS2) were assessed in order to optimise parameters of the analytical method. The final procedure involved the extraction of acrylamide with acetonitrile, solid-phase extraction with dispersive primary secondary amine (PSA) and amino columns, and the detectio…
Preparation and characterization of octadecyl acrylate monoliths for capillary electrochromatography by photochemical, thermal, and chemical initiati…
2013
Monolithic stationary phases based on octadecyl acrylate for CEC using different initiating systems (UV irradiation, thermal, and chemical initiation) in the presence of lauroyl peroxide as initiator were synthesized. For each initiation mode, the influence of the porogenic solvent composition on both the morphological and electrochromatographic properties of the resulting monoliths was investigated. Under optimal conditions, excellent efficiencies for the photochemically and chemically polymerized monoliths (minimum plate heights of 6.9–10.7 and 6.5–12.6 μm, respectively) were achieved. Thermally initiated columns gave lower efficiency values, permeabilities, and longer analysis times comp…