Search results for "computed tomography"

showing 10 items of 713 documents

Imaging processing for CT angiography of the cervicocranial arteries: evaluation of reformatting technique.

2007

Purpose. The aim of this study was to compare computed tomography angiography (CTA) sliding-thin-slab (STS) multiplanar reformatting (MPR), STS maximum intensity projection (MIP) and three-dimensional (3D) volume rendering (VR) reformatting techniques in the evaluation of cervicocranial arteries. Materials and methods. Twenty patients examined with multislice CT were included in this study. CTA images were reformatted as STS-MIP, STS-MPR and 3DVR in orthogonal planes and in the oblique-coronal plane. Images were evaluated in consensus by two radiologists, with a third radiologist to resolve discordances in grading image quality parameters. The Spearman correlation analysis was performed to …

Malemedicine.medical_specialtyImage qualityCT CT angiography Cervicocranial arterieImaging Three-DimensionalmedicineImage Processing Computer-AssistedHumansRadiology Nuclear Medicine and imagingVertebral ArteryComputed tomography angiographyNeuroradiologyAgedmedicine.diagnostic_testbusiness.industryUltrasoundAngiographyBrainVolume renderingGeneral MedicineCerebral ArteriesMiddle AgedCerebral AngiographyCerebrovascular DisordersCarotid ArteriesMaximum intensity projectionAngiographyCervical VertebraeFemaleRadiologyImaging processingNuclear medicinebusinessTomography X-Ray ComputedLa Radiologia medica
researchProduct

Massive pulmonary embolism in a young boy with T-cell leukaemia. Successful thrombolytic therapy by recombinant tissue plasminogen activator (rtPA).

2014

SummaryAcute pulmonary embolism (PE) is a serious complication in association with malignant diseases. We describe the successful treatment of PE applying a systemic thrombolytic therapy in a 4-year-old boy with acute lymphoblastic leukaemia.The thrombolytic therapy with recombinant tissue plasminogen activator (rtPA) 0.1 mg/ kg bodyweight per hour for six hours was continued for six days without important side effects. In particular no bleeding complications were observed. Computed tomography with contrast revealed a remarkable regression of the central PE. Without further delays the chemotherapy was resumed.

Malemedicine.medical_specialtyLeukemia T-Cellmedicine.medical_treatmentComputed tomographyFibrinolytic AgentsmedicineHumansRecombinant tissue plasminogen activatorChemotherapymedicine.diagnostic_testbusiness.industryAnticoagulantsHematologyHeparin Low-Molecular-Weightmedicine.diseaseRecombinant ProteinsSurgeryPulmonary embolismTreatment OutcomeChild PreschoolTissue Plasminogen ActivatorLymphoblastic leukaemiaDrug Therapy CombinationbusinessComplicationPulmonary EmbolismT cell leukaemiaHamostaseologie
researchProduct

Reproducible coronary plaque quantification by multislice computed tomography

2007

BACKGROUND: The aim of this study was to investigate reproducibility and accuracy of computer-assisted coronary plaque measurements by multislice computed tomography coronary angiography (QMSCT-CA). METHODS AND RESULTS: Forty-eight patients undergoing MSCT-CA and coronary arteriography for symptomatic coronary artery disease and quantitative intravascular ultrasound (IVUS, QCU) were examined. Two investigators performed the QMSCT-CA twice and a third investigator performed the QCU, all blinded for each other's results. There was no difference found for the matched region of interest (ROI) lengths (QCU 29.4 +/- 13 mm vs. QMSCT-CA 29.6 +/- 13 mm, P = 0.6; total length = 1,400 mm). The compari…

Malemedicine.medical_specialtyLumen (anatomy)Coronary Angiographymultislice computed tomographyintravascular ultrasoundCoronary artery diseasePredictive Value of TestsRegion of interestCoronary plaqueImage Interpretation Computer-AssistedIntravascular ultrasoundmedicineHumansRadiology Nuclear Medicine and imagingUltrasonography InterventionalAgedObserver VariationReproducibilitymedicine.diagnostic_testbusiness.industryReproducibility of ResultsGeneral MedicineMultislice computed tomographyMiddle Agedmedicine.diseaseimage processingResearch DesignPredictive value of testsFemaleRadiologyTomography X-Ray ComputedSettore MED/36 - Diagnostica Per Immagini E RadioterapiaCardiology and Cardiovascular Medicinebusinesscoronary artery diseaseCatheterization and Cardiovascular Interventions
researchProduct

Radiomics analysis of 18F-Choline PET/CT in the prediction of disease outcome in high-risk prostate cancer: an explorative study on machine learning …

2021

Objective: The aim of this study was (1) to investigate the application of texture analysis of choline PET/CT images in prostate cancer (PCa) patients and (2) to propose a machine-learning radiomics model able to select PET features predictive of disease progression in PCa patients with a same high-risk class at restaging. Material and methods: Ninety-four high-risk PCa patients who underwent restaging Cho-PET/CT were analyzed. Follow-up data were recorded for a minimum of 13 months after the PET/CT scan. PET images were imported in LIFEx toolbox to extract 51 features from each lesion. A statistical system based on correlation matrix and point-biserial-correlation coefficient has been impl…

Malemedicine.medical_specialtyMachine learningcomputer.software_genre030218 nuclear medicine & medical imagingCholineCorrelationMachine Learning03 medical and health sciences0302 clinical medicineArtificial IntelligencePositron Emission Tomography Computed TomographymedicineHumansRadiology Nuclear Medicine and imagingCholine; Machine learning; Positron emission tomography computed tomography; Prostate cancer; Radiomics.Prospective StudiesEntropy (energy dispersal)Prospective cohort studySurvival analysisPET-CTbusiness.industryProstatic NeoplasmsGeneral MedicineLinear discriminant analysismedicine.diseasePrimary tumorFeature (computer vision)030220 oncology & carcinogenesisRadiologyArtificial intelligenceNeoplasm Recurrence LocalbusinesscomputerMachine learning Positron emission tomography computed tomography Prostate cancer Radiomics Artificial Intelligence
researchProduct

Influence of convolution filtering on coronary plaque attenuation values: observations in an ex vivo model of multislice computed tomography coronary…

2007

Attenuation variability ( measured in Hounsfield Units, HU) of human coronary plaques using multislice computed tomography (MSCT) was evaluated in an ex vivo model with increasing convolution kernels. MSCT was performed in seven ex vivo left coronary arteries sunk into oil followingthe instillation of saline (1/infinity) and a 1/50 solution of contrast material ( 400 mgI/ml iomeprol). Scan parameters were: slices/ collimation, 16/0.75 mm; rotation time, 375 ms. Four convolution kernels were used: b30f-smooth, b36f-medium smooth, b46f-medium and b60f-sharp. An experienced radiologist scored for the presence of plaques and measured the attenuation in lumen, calcified and noncalcified plaques …

Malemedicine.medical_specialtyMultislice computed tomographyConvolutions KernelsCoronary angiographyIomeprolMyocardial IschemiaContrast MediaCoronary Artery DiseaseIn Vitro TechniquesCoronary AngiographySensitivity and SpecificityIopamidolCoronary artery diseasechemistry.chemical_compoundHounsfield scaleMedicine and Health SciencesmedicineImage Processing Computer-AssistedHumansRadiology Nuclear Medicine and imagingAgedConvolutions kernelsCoronary Plaquebusiness.industryAttenuationUltrasoundMultislice computed tomography Coronary angiography Coronary plaque Convolutions kernelsModels CardiovascularGeneral MedicineMiddle Agedmedicine.diseaseImage EnhancementIopamidolCoronary arteriesmedicine.anatomical_structurechemistryRadiology Nuclear Medicine and imagingFemaleRadiologybusinessNuclear medicineTomography Spiral ComputedCardiacCoronary plaqueEx vivoMultislice Computed Tomographymedicine.drug
researchProduct

Radiation dose from multidetector CT studies in children: results from the first Italian nationwide survey

2014

Background Multidetector CT (MDCT) scanners have con- tributed to the widespread use of CT in paediatric imaging. However, concerns are raised for the associated radiation exposure. Very few surveys on radiation exposure from MDCT studies in children are available. Objective The aim of this study was to outline the status of radiation exposure in children from MDCT practice in Italy. Materials and methods In this retrospective multicentre study we asked Italian radiology units with an MDCT scanner with at least 16 slices to provide dosimetric and acquisition param- eters of CT examinations in three age groups (1–5, 6–10, 11– 15 years) for studies of head, chest and abdomen. The dosi- metric…

Malemedicine.medical_specialtyMultivariate analysisAdolescentPatient characteristicsMultidetector ctRadiation DosageNationwide surveyMultidetector computed tomography . Dose . Diagnostic reference level . ChildAge groupsMultidetector Computed TomographyHumansMedicineRadiology Nuclear Medicine and imagingChildRetrospective StudiesNeuroradiologybusiness.industryRadiation doseInfantRetrospective cohort studyItalyChild PreschoolPediatrics Perinatology and Child HealthFemaleRadiologybusinessNuclear medicine
researchProduct

Transmurality of scar influences the effect of a hybrid-intervention with autologous bone marrow cell injection and aortocoronary bypass surgery (MNC…

2010

Abstract Background Cell therapy (CTx) is a strategy to support cardiac regeneration after myocardial infarction (MI). Thus far, clinical studies provided mixed results. Here, we investigated whether transmurality of the infarct may play a relevant role. Methods 18 patients (63±3years, 15 male) undergoing elective coronary artery bypass graft (CABG) surgery 2.2±0.7months post MI participated. 10 had transmural and 8 non-transmural infarct scars assessed by Tc-99m-MIBI Single-Photon Emission Computed Tomography (SPECT) and F18-FDG-Positron-Emission-Tomography (PET). During surgery, 10ml of sternal bone marrow were obtained, mononuclear cells (MNC) were isolated. At the end of surgery MNC wer…

Malemedicine.medical_specialtyMyocardial InfarctionMedizinScarsTransplantation AutologousPeripheral blood mononuclear cellInjectionsCell therapyCicatrixInternal medicinemedicineHumansMyocardial infarctionCoronary Artery BypassAgedBone Marrow TransplantationTomography Emission-Computed Single-PhotonEjection fractionmedicine.diagnostic_testbusiness.industryMiddle Agedmedicine.diseaseSurgeryTreatment Outcomemedicine.anatomical_structurePositron-Emission TomographyCardiologyFemalemedicine.symptomCardiology and Cardiovascular MedicinebusinessPerfusionEmission computed tomographyArteryInternational Journal of Cardiology
researchProduct

The role of computed tomography in the diagnosis of brain tumors in infants and children.

1978

CT has considerably facilitated the diagnosis of intracranial tumors, especially in infants and children. The authors review their experience with a series of 260 children with proven brain tumors. In most cases CT is so conclusive that other diagnostic techniques are no longer often needed. Pneumoencephalography in particular has largely been replaced by CT in recent years in the authors' departments, and the frequency of central ventriculography with contrast material has decreased substantially. Particular diagnostic difficulties with regard to tumors near to or within the caudal brain stem, some posterior fossa tumors, small vermian tumors, and tumors of the cerebral hemispheres are dis…

Malemedicine.medical_specialtyNeurologymedicine.medical_treatmentComputed tomographyFourth ventriclemedicineHumansRadiology Nuclear Medicine and imagingPneumoencephalographyCerebellar NeoplasmsChildNeuroradiologyPilocytic astrocytomamedicine.diagnostic_testbusiness.industryBrain NeoplasmsAge FactorsInfantmedicine.diseasePosterior Fossa TumorsCranial Fossa PosteriorFemaleNeurology (clinical)NeurosurgeryRadiologyCardiology and Cardiovascular MedicinebusinessTomography X-Ray ComputedNeuroradiology
researchProduct

Primary de novo intraosseous carcinoma : report of a new case

2010

Primary de novo intraosseous carcinoma of the jaws has been rarely reported. We present a new case of this unusual tumour and discuss its histopathological and clinical aspects. The subject was a 76-year-old man who was seen due to complaints of pain and the presence of gingival changes in the left mandible. A panoramic radiograph and computed tomography revealed a large mandibular radiolucency. A segmentary mandibulectomy was performed and histopathologic examination proved that the tumour was an intraosseous squamous cell carcinoma. Surgeons should appreciate the aggressiveness of this tumour, despite adequate surgical treatment

Malemedicine.medical_specialtyPanoramic radiographmedicine.diagnostic_testbusiness.industryMandibleComputed tomography:CIENCIAS MÉDICAS [UNESCO]medicine.diseaseSurgeryMandibular NeoplasmsIntraosseous carcinomaMandibulectomyOtorhinolaryngologyUNESCO::CIENCIAS MÉDICASCarcinoma Squamous CellmedicineCarcinomaHumansSurgeryBasal cellSurgical treatmentbusinessGeneral DentistryAged
researchProduct

Reducing Patient Radiation Dose With Image Noise Reduction Technology in Transcatheter Aortic Valve Procedures

2015

X-ray radiation exposure is of great concern for patients undergoing structural heart interventions. In addition, a larger group of medical staff is required and exposed to radiation compared with percutaneous coronary interventions. This study aimed at quantifying radiation dose reduction with implementation of specific image noise reduction technology (NRT) in transcatheter aortic valve implantation (TAVI) procedures. We retrospectively analyzed 104 consecutive patients with TAVI procedures, 52 patients before and 52 after optimization of x-ray radiation chain, and implementation of NRT. Patients with 1-step TAVI and complex coronary intervention, or complex TAVI procedures, were excluded…

Malemedicine.medical_specialtyPercutaneousImage quality030204 cardiovascular system & hematology030218 nuclear medicine & medical imagingTranscatheter Aortic Valve ReplacementIntraoperative Period03 medical and health sciencesKerma0302 clinical medicineGermanyInternal medicineMultidetector Computed TomographyImage noise reductionmedicineHumansFluoroscopyCardiac skeletonRadiation InjuriesRetrospective StudiesAged 80 and overmedicine.diagnostic_testbusiness.industryIncidenceDose-Response Relationship RadiationRetrospective cohort studyAortic Valve StenosisPrognosismedicine.diseaseSurgery Computer-AssistedFluoroscopyAortic valve stenosisCardiologyFemaleRadiologyCardiology and Cardiovascular MedicinebusinessFollow-Up StudiesThe American Journal of Cardiology
researchProduct