Reliability of manual segmentation of cornea, contact lens and tear film using a high-resolution OCT

2015

In this study, we aimed to evaluate the intra/inter-session and intra/inter-observer variability of manual segmentation of thickness of the pre-lens tear film, contact lens (CL), post-lens tear film, epithelium, bowman’s layer, stroma and the whole cornea and CLs with a flat and a steep fit, using a commercial high-resolution spectral domain optical coherence tomographer (OCT). Two different observers obtained three repeated measures in two separate sessions. A high correlation was found between the values obtained by the two different observers, except for the thinner layers, epithelium, and Bowman’s layer. Inter-observer analysis showed a high consistency in the measurements obtained by b…

Materials scienceManual layer segmentationOpticsCLs upper limitsOptical coherence tomographyCorneamedicineEpithelial thicknessRepeatabilityScience & Technologymedicine.diagnostic_testOptical coherence tomographybusiness.industryResolution (electron density)RepeatabilityAtomic and Molecular Physics and Opticseye diseasesTear film thicknessContact lensCorneal thicknessmedicine.anatomical_structureManual segmentationsense organsbusinessBiomedical engineering
researchProduct

Equivalences between refractive index and equilibrium water content of conventional and silicone hydrogel soft contact lenses from automated and manu…

2007

PURPOSE: The purpose of the present study was to develop mathematical relationships that allow obtaining equilibrium water content and refractive index of conventional and silicone hydrogel soft contact lenses from refractive index measures obtained with automated refractometry or equilibrium water content measures derived from manual refractometry, respectively. METHODS: Twelve HEMA-based hydrogels of different hydration and four siloxane-based polymers were assayed. A manual refractometer and a digital refractometer were used. Polynomial models obtained from the sucrose curves of equilibrium water content against refractive index and vice-versa were used either considering the whole range…

Materials scienceSiliconesRefractive indexBiomedical EngineeringAnalytical chemistryBiocompatible Materials02 engineering and technologyBiomaterials03 medical and health sciences0302 clinical medicineRefractometerHumansBrix sucrose scaleBrix scaleCLR 12-70Water contentSoft contact lenseschemistry.chemical_classificationScience & TechnologyEquilibrium water contentWaterHydrogelsAtago N2EsucrosePolymerSilicone hydrogelconventional soft contact lensesContact Lenses Hydrophilic021001 nanoscience & nanotechnologyContact lensRefractometrychemistrySelf-healing hydrogelsSilicone hydrogel030221 ophthalmology & optometry0210 nano-technologyRefractometryRefractive indexJournal of Biomedical Materials Research Part B: Applied Biomaterials
researchProduct

Microscopic observations of superficial ultrastructure of unworn siloxane-hydrogel contact lenses by cryo-scanning electron microscopy

2006

The purpose of this study was to analyze three commercial siloxane-hydrogel contact lens materials, lotrafilcon A, balafilcon A, and galyfilcon A, by cryogenic scanning electron microscopy (cryoSEM). The fully hydrated lenses were frozen in slush liquid nitrogen and qualitatively observed in a cryogenic scanning electron microscope. The superficial ultrastructure of the siloxane-hydrogels was observed at the areas where the lens fractured during sample cryogenic preparation. There are qualitative differences among the three examined materials in the complex polymer network structure existing between the outer layer and the underlying polymer. CryoSEM, although destructive, is a useful tool …

Materials scienceSiloxanesScanning electron microscopeSurface PropertiesBiomedical Engineering02 engineering and technologyContact lens materialsHydrogel Polyethylene Glycol Dimethacrylatelaw.inventionBiomaterials03 medical and health sciences0302 clinical medicineOpticssilicone-hydrogellawMicroscopyMaterials TestingHumansCryo-scanning electron microscopyComposite materialchemistry.chemical_classificationScience & Technologybusiness.industryCryoelectron MicroscopyCryoSEM microscopyPolymerLiquid nitrogenpolymer surface021001 nanoscience & nanotechnologyContact Lenses HydrophilicSiloxane-hydrogel contact lensescryoSEMLens (optics)Contact lenschemistry030221 ophthalmology & optometryUltrastructuremicroscopysiloxane-hydrogels0210 nano-technologybusiness
researchProduct

Microscopic observation of unworn siloxane-hydrogel soft contact lenses by atomic force microscopy

2006

In the present study, samples of lotrafilcon A, balafilcon A, and galyfilcon A contact lenses were observed by atomic force microscopy (AFM) in tapping mode at areas ranging from 0.25 to 400 m2. Mean roughness (Ra), root-mean-square roughness (Rms) and maximum roughness (Rmax) in nanometers were obtained for the three lens materials at different magnifications. The three contact lenses showed significantly different surface topography. However, roughness values were dependent of the surface area to be analyzed. For a 1 m2 area, statistics revealed a significantly more irregular surface of balafilcon A (Ra = 6.44 nm; Rms = 8.30 nm; Rmax = 96.82 nm) compared with lotrafilcon A (Ra = 2.40 nm; …

Materials scienceSiloxanesSurface PropertiesBiomedical EngineeringNanotechnology02 engineering and technologyMicroscopy Atomic ForceHydrogel Polyethylene Glycol DimethacrylateBiomaterialsAtomic force microscopy03 medical and health scienceschemistry.chemical_compoundSurface roughness0302 clinical medicineMaterials TestingSurface roughnessHumansScience & TechnologyAtomic force microscopyContact Lenses Hydrophilic021001 nanoscience & nanotechnologySiloxane-hydrogel contact lenses3. Good healthMicroscopic observationchemistrySiloxaneWettability030221 ophthalmology & optometry0210 nano-technologyJournal of Biomedical Materials Research Part B: Applied Biomaterials
researchProduct

Optical quality comparison among different Boston contact lens materials.

2014

BACKGROUND The aim was to assess the optical quality of four Boston contact lens materials with an optical device based on Schlieren interferometry. METHODS The NIMO TR1504 (Lambda-X, Nivelles, Belgium) was used to measure higher-order aberrations and their corresponding root mean square values of four different rigid gas permeable contact lenses made from four different Boston materials: EO, ES, XO and XO2 . For each lens, 30 measurements were performed with two optical apertures: 3.0 mm and 6.0 mm. The modulation transfer function, point spread function, Strehl ratio and a simulation of the image provided by the lens were computed from the Zernike coefficients measured up to the fourth or…

Materials sciencebusiness.industryApertureContact LensesStrehl ratio02 engineering and technology021001 nanoscience & nanotechnologylaw.inventionRoot mean squareContact lensLens (optics)03 medical and health sciencesOphthalmologyInterferometry0302 clinical medicineOpticslawSchlierenOptical transfer function030221 ophthalmology & optometry0210 nano-technologybusinessOptometryClinicalexperimental optometry
researchProduct

OCT applications in contact lens fitting

2022

Optical Coherence Tomography (OCT) is a noninvasive, high-speed, high-resolution imaging technology based in the Michaelson interferometry. A near-infrared light beam is used to register the intensity variations for the light backscattered on each sample layer. Due to the high repeatability on corneal measurements, spectral domain OCT (SD-OCT) is the gold standard when talking about in vivo, non-invasive anterior segment imaging. Changes in the morphology of various ocular surfaces such as the cornea, conjunctiva, limbus or tear film with soft (SCL), rigid, corneal or scleral lens (SL) wear can be described by OCT measurements. For instance, evaluation of the corneoscleral region is essenti…

Materials sciencegenetic structuresmedicine.medical_treatmentlaw.inventionCorneaOptical coherence tomographyScleral lenslawCorneamedicineHumansmedicine.diagnostic_testOrthokeratologyGeneral MedicineRepeatabilityContact Lenses Hydrophiliceye diseasesContact lensLens (optics)OphthalmologyInterferometrymedicine.anatomical_structureTearssense organsConjunctivaTomography Optical CoherenceOptometryBiomedical engineeringContact Lens and Anterior Eye
researchProduct

Opportunities and threats to contact lens practice: A global survey perspective

2021

Aim: To understand the views of contact lens (CL) practitioners across the globe regarding what they perceive as opportunities and threats in CL practice. Methods: A self-administered anonymised questionnaire, constructed in English and translated in six more languages, was distributed through reputed international professional bodies and academic institutions worldwide. The questionnaire included items on demographic characteristics, type of practice, and questions designed to explore practitioners’ perspective on the future of their CL practice over the next five years. Results: A total of 2408 valid responses were analysed. Multifocal CLs for presbyopia, CLs for myopia control, use of da…

Medical educationUniversitiesContact LensesPerspective (graphical)GlobeContact lens practicePresbyopiaGeneral MedicinePresbyopiamedicine.diseaseBiocompatible materialContact lensOphthalmologymedicine.anatomical_structureCLs upper limitsOpportunitieSurveys and QuestionnairesMyopiamedicineHumansDaily disposablePsychologyThreatOptometry
researchProduct

Power profiles in multifocal contact lenses with variable multifocal zone

2016

BACKGROUND The power profile of multifocal contact lenses has been demonstrated to report important information that could be used during the fitting process. The aim of this work is to describe the power profile of a recent set of gas permeable multifocal contact lenses as a function of the pupil radius. METHODS The measured multifocal contact lenses have a centre-distance design, and are available with five distance-vision diameters (XS, S, M, L and XL) and two different additions: Type A (up to +2.00 D) and Type B (up to +2.50 D). The optical device NIMO TR1504 (Lambda-X, Nivelles, Belgium) was used to obtain the power profile measurements. The optical lens power distribution as a functi…

Optical PhenomenaContact LensesApertureVisual AcuityRefraction Ocularlaw.invention03 medical and health sciencesNear vision0302 clinical medicineOpticslawHumansPhysicsbusiness.industryEquipment DesignPresbyopiaRadiusFunction (mathematics)Power (physics)Lens (optics)OphthalmologyVariable (computer science)030221 ophthalmology & optometrybusiness030217 neurology & neurosurgeryOptometryClinical and Experimental Optometry
researchProduct

Oxygen permeability of hydrogel contact lenses with organosilicon moieties

2002

Oxygen transport through two extended wear (day and night) hydrogel contact lenses that contain organosilicon moieties (balafilcon A and lotrafilcon A) was studied in the hydrate (hydrogel) and dry (xerogel) states. The water uptake increased the oxygen permeability [(Dk)app] and transmissibility [Dk/L(av)] coefficients of the dry materials by about 70%. The (Dk)app for the hydrated lenses was determined following the so-called stack procedure. The values obtained were 107 +/- 4 barrer for balafilcon A and 141 +/- 5 barrer for lotrafilcon A, about 5-10 times larger than those previously reported for conventional (without organosilicon moieties) extended wear hydrogels contact lenses. The Dk…

Optics and PhotonicsMaterials scienceBiophysicsAnalytical chemistrychemistry.chemical_elementBioengineeringOxygenHydrogel Polyethylene Glycol DimethacrylatePermeabilityBiomaterialschemistry.chemical_compoundOxygen permeabilityMaterials TestingPolymer chemistryOrganosilicon CompoundsOrganosiliconOxygen transportWaterContact Lenses HydrophilicOxygenchemistryMechanics of MaterialsPermeability (electromagnetism)Self-healing hydrogelsCeramics and CompositesBarrerHydrateBiomaterials
researchProduct

Power Profiles and In Vitro Optical Quality of Scleral Contact Lenses: Effect of the Aperture and Power

2017

To assess the power profile and in vitro optical quality of scleral contact lenses with different powers as a function of the optical aperture. The mini and semiscleral contact lenses (Procornea) were measured for five powers per design. The NIMO TR-1504 (Lambda-X) was used to assess the power profile and Zernike coefficients of each contact lens. Ten measurements per lens were taken at 3- and 6-mm apertures. Furthermore, the optical quality of each lens was described in Zernike coefficients, modulation transfer function, and point spread function (PSF). A convolution of each lens PSF with an eye-chart image was also computed. The optical power fluctuated less than 0.5 diopters (D) along th…

Optics and PhotonicsMaterials scienceContact LensesAperturePhysics::OpticsOptical powerAstrophysics::Cosmology and Extragalactic AstrophysicsIn Vitro TechniquesRefraction Ocularlaw.invention03 medical and health sciences0302 clinical medicineOpticslawOptical transfer functionHumansDioptreAnalysis of Variancebusiness.industryLens speedEquipment DesignLens (optics)Contact lensOphthalmology030221 ophthalmology & optometryGradient-index opticsbusiness030217 neurology & neurosurgeryEye & Contact Lens: Science & Clinical Practice