Tolerability of 24-hour intraocular pressure monitoring of a pressure-sensitive contact lens.
2013
Purpose To investigate tolerability and safety of a new diagnostic device for 24-hour intraocular pressure monitoring in healthy subjects and age-matched glaucoma patients. Patients and methods Twenty healthy subjects (group 1) and 20 age-matched glaucoma patients (group 2) were included in this prospective, single-center, open, observational parallel group study. The SENSIMED Triggerfish Sensor is a soft disposable contact lens embedding a telemetry chip and strain gauge sensor for continuous intraocular pressure monitoring. The Sensor was placed in 1 eye for 24 hours. Tolerability was evaluated using a visual analog scale (range, 0 to 100; 0=no discomfort; 100=very severe discomfort). Saf…
Intraocular pressure after small incision cataract surgery: temporal sclerocorneal versus clear corneal incision.
2001
To compare intraocular pressure (IOP) after phacoemulsification and foldable intraocular lens (IOL) implantation using a temporal sclerocorneal or clear corneal incision.Department of Ophthalmology, Johannes Gutenberg-University, Mainz, Germany.One hundred patients (100 eyes) with cataract having phacoemulsification with posterior chamber IOL implantation were randomly assigned to receive a temporal sclerocorneal or clear corneal tunnel incision. Intraocular pressure was measured preoperatively and 6 hours, 1, 2, and 3 days, and 5 months postoperatively. Statistical significance was determined by nonparametric group comparisons using 2-sample random Wilcoxon tests.Six hours postoperatively,…
Falsely elevated intraocular pressure due to increased central corneal thickness
1999
PURPOSE: To evaluate whether ocular hypertensive subjects have a higher central corneal thickness than other individuals. METHODS: In this prospective study, 48 subjects with ocular hypertension, 63 patients with open-angle glaucoma, 56 nonglaucomatous patients with diabetes mellitus, and 106 control subjects were evaluated. Corneal thickness was measured by ultrasound pachymetry, and intraocular pressure was determined by Goldmann applanation tonometry. RESULTS: Central corneal thickness was significantly higher in the ocular hypertensive subjects, mean +/- S.D., 592+/-39 microm, than in the patients with glaucoma (536+/-34 microm), the nonglaucomatous patients with diabetes mellitus (550+…
Corneoscleral contact lenses for visual rehabilitation after keratoplasty surgery.
2019
Abstract Purpose To report the use of corneoscleral lenses (CSL) in keratoconus patients who were unsatisfied with their visual outcomes after keratoplasty surgery. Methods Eleven consecutive cases with unsatisfactory vision with spectacles, due to irregular astigmatism, preferred to try CSL before SL due to handling or economic issues. An eye examination included refraction and visual acuity assessment, anterior eye biomicroscopy, ocular fundus examination, corneal topographic analysis, endothelial-cell count (ECC) and evaluation of corneal biomechanical parameters (corneal resistance factor, CRF; corneal hysteresis, CH; corneal-compensated intraocular pressure, IOPcc). The fitting process…
Impact of Corneoscleral Contact Lens Usage on Corneal Biomechanical Parameters in Keratoconic Eyes
2019
Objective To analyze the changes in corneal biomechanical parameters of keratoconic eyes with and without intracorneal ring segment (ICRS) implants after 1 year of corneoscleral contact lens (CScL) wear. Methods Seventy-four eyes of 74 patients were divided into three groups: healthy subjects (29 eyes, control group), and 2 groups of subjects with keratoconic eyes (one group of 20 eyes with ICRS implants and one of 25 eyes without them), which were fitted with CScL. Corneal hysteresis (CH), corneal resistance factor (CRF), and corneal-compensated intraocular pressure (IOPcc) were evaluated before fitting CScL and after 1 year of CScL wear. In addition, endothelial cell count (ECC) and centr…
A new approach based on Machine Learning for predicting corneal curvature (K1) and astigmatism in patients with keratoconus after intracorneal ring i…
2014
Keratoconus (KC) is the most common type of corneal ectasia. A corneal transplantation was the treatment of choice until the last decade. However, intra-corneal ring implantation has become more and more common, and it is commonly used to treat KC thus avoiding a corneal transplantation. This work proposes a new approach based on Machine Learning to predict the vision gain of KC patients after ring implantation. That vision gain is assessed by means of the corneal curvature and the astigmatism. Different models were proposed; the best results were achieved by an artificial neural network based on the Multilayer Perceptron. The error provided by the best model was 0.97D of corneal curvature …
Evaluation of the anterior chamber angle in keratoconus and normal subjects.
2015
To evaluate the anterior chamber angle in keratoconus eyes by use of the Visante™ OCT and Orbscan™ II.Anterior chamber angle was measured with the Visante™ OCT and Orbscan™ II in 52 subjects, 26 KC subjects and 26 age and control subjects.When comparing the nasal and temporal angles obtained with the two techniques no correlation was found (R(2) always below 0.01) in either the control subjects or in the KC subjects. Despite this, there was an overall statistically significant difference in mean anterior chamber angles (p0.001) between Visante™ OCT and Orbscan™ II. There was no statistical difference (p0.05) between nasal and temporal anterior chamber angles when comparing controls and KC s…
Intrastromal corneal ring segment implantation in paracentral keratoconus with coincident topographic and coma axis.
2012
To evaluate the efficacy, predictability, and safety of implantation of Ferrara-type intrastromal corneal ring segments (ICRS) for refractive correction of paracentral keratoconus.Fernández-Vega Ophthalmological Institute, Oviedo, Spain.Cohort study.Snellen uncorrected (UDVA) and corrected (CDVA) distance visual acuities and residual refractive errors were recorded before and 6 months after ICRS implantation for keratoconus. The tunnels for ICRS implantation were created with a femtosecond laser. The power vector and the Alpins method were used to analyze postoperative refractive outcomes.The study evaluated 56 eyes of 49 patients. The mean UDVA was 0.17 ± 0.14 (SD) preoperatively and 0.41 …
Subjective Satisfaction in Long-term Orthokeratology Patients
2013
Purpose: To AU3 evaluate the subjective satisfaction in visual stability, night vision complains, and light distortion phenomena, and also the number of hours and days per week of lens wear, in patients with myopia undergoing orthokeratology (OK) treatment for at least 1 year. Methods: A visual analog scale (VAS) questionnaire containing 18 items was administered to 44 patients, 29 women and 15 men (mean age, 24.39 6 9.11 years), with a baseline spherical equivalent refractive error of 22.40 6 0.94 diopters and astigmatism up to 20.5 diopters. Average treatment period by the time of data collection was 19 6 7 months. Patients rated their satisfaction with the correction, with complaints of …
Validation of a New Instrument for Self-care in Spanish Palliative Care Professionals Nationwide.
2015
AbstractSelf-care is a cornerstone issue for those who deal with stressful events, as it is the case of palliative care professionals. It has been related to awareness, coping with death and quality of life, among others, but no measurement instruments have been used in palliative care professionals. This research presents and validates a brief new measure with clinical and psychometric good properties, called Professional Self-Care Scale (PSCS). The PSCS assesses professionals’ self-care in three areas: physical self-care, inner self-care, and social self-care. Data come from a cross-sectional survey in a sample of 385 professionals of palliative care. The Mindful Attention Awareness Scale…