Search results for "cornea"
showing 10 items of 404 documents
Multilayer amniotic membrane transplantation in severe ocular graft versus host disease
2001
To clarify the usefulness of multilayer amniotic membrane transplantation in an unusual case of calcareous corneal degeneration in a patient with graft-versus-host disease.A 20-year-old Caucasian woman had bilateral calcareous corneal degeneration of one year of evolution, secondary to graft-versus-host disease. Treatment for both eyes with topical steroids and antibiotic ointment was not successful. Right eye had a spontaneous corneal perforation, and a three-layer circle amniotic membrane graft was applied to the whole cornea.During a follow-up period of 20 months we observed stability of the corneal epithelium and stroma. The amniotic membrane-covered area showed rapid epithelization, re…
Influence of optic quality on contrast sensitivity and visual acuity in eyes with a rigid or flexible phakic intraocular lens
2009
Purpose To determine whether the difference in optic quality between 2 types of phakic intraocular lenses (pIOLs) affects visual quality. Setting Fundacion Oftalmologica del Mediterraneo, Valencia, Spain. Methods Before implantation of a pIOL for myopia, all eyes had an examination including corrected (CDVA) and uncorrected (UDVA) distance visual acuity testing, corneal endothelial cell count (ECC), and intraocular pressure (IOP) measurement. The postoperative outcomes, determined at least 1 year after surgery, were CDVA; UDVA; contrast sensitivity function under photopic, mesopic, and mesopic with glare conditions; ECC; IOP; keratometry (Scheimpflug photography); and total ocular aberratio…
Impact of the line of sight on toric phakic intraocular lenses for hyperopia
2003
We present a hyperopic patient with a decentered line of sight in whom the residual refractive error after toric phakic intraocular lens (TP IOL) implantation was improved by displacement and individualized treatment. A 35-year-old woman presented with asthenopic complaints 2 months after bilateral TP IOL implantation and IOL rotation 4 weeks later. Examination revealed the line of sight to be nasally and inferiorly decentered in relation to the center of the pupil. A more nasal reenclavation of the TP IOL decreased the coma, and the uncorrected visual acuity was 20/20. We conclude that line of sight should be measured before TP IOL implantation, especially in hyperopic eyes.
Avaliação da resposta de acomodação após tarefas visuais próximas usando diferentes dispositivos eletrônicos portáteis
2015
ABSTRACT Purpose: To assess the accommodation response after short reading periods using a tablet and a smartphone as well as determine potential differences in the accommodation response at various stimulus vergences using a Hartmann- Shack aberrometer. Methods: Eighteen healthy subjects with astigmatism of less than 1 D, corrected visual acuity of 20/20 or better, and normal findings in an ophthalmic examination were enrolled. Accommodation responses were obtained under three different conditions: accommodation system of the eye relaxed and visually stressed with a tablet and an smartphone for 10 min, at a distance of 0.25 m from the subject's eyes. Three measurements of accommodation res…
Quantitative corneal anatomy in emmetropic subjects.
2006
PURPOSE Currently there is little information available about the corneal thickness values of healthy emmetropic subjects. Therefore, the authors decided to analyze the corneal thickness in healthy emmetropic subjects. METHODS The authors analyzed the difference in thickness values between the thinnest corneal site and the central and paracentral cornea in 124 eyes of 124 healthy emmetropic white subjects. RESULTS The mean difference between the thinnest site of the cornea and the thickness values obtained in the areas analyzed was as follows: 12+/-6 microm center; 140+/-19 microm superonasal; 133+/-23 microm nasal; 117+/-26 microm inferonasal; 122+/-19 microm superotemporal ; 89+/-22 micro…
Differences in Corneal Anatomy in a Pair of Monozygotic Twins Due to Continuous Contact Lens Wear
2003
Purpose To study the differences in the corneal anatomy in a pair of 31-year-old monozygotic female twins, one of whom has been a contact lens wearer for the past 15 years and the other is a nonwearer. Methods We analyzed the corneal thickness and the corneal endothelial cell density of the monozygotic twins and of two age-matched control groups, one made up of non-contact lens wearers (35 eyes of 35 patients; mean age, 29.32 +/- 2.83 years) and the other made up of soft contact lens wearers (30 eyes of 30 patients; mean age, 33.08 +/- 3.72 years; mean duration of contact lens use, 10.62 +/- 4.32 years). Five corneal thickness measurements were carried out with the Orbscan Topography System…
Femtosecond laser versus mechanical microkeratome laser in situ keratomileusis for myopia: Metaanalysis of randomized controlled trials.
2011
Purpose To examine differences in efficacy, accuracy, safety, and changes in aberrations between femtosecond and mechanical microkeratome laser in situ keratomileusis (LASIK) for myopia. Setting Department of Ophthalmology, Shanghai First People's Hospital Affiliated to Shanghai Jiaotong University, Shanghai, China. Design Evidence-based manuscript. Methods Data sources, including PubMed, Medline, EMBASE, and Cochrane Controlled Trials Register, were searched to identify potentially relevant prospective randomized controlled trials. Primary outcome measures were efficacy (uncorrected distance visual acuity ≥20/20), accuracy (±0.50 diopter mean spherical equivalent), and safety (loss of ≥2 l…
Effects of LASIK on Corneal Endothelium Using the 15-kHz IntraLase Femtosecond Laser
2011
PURPOSE: To assess the effects of LASIK with the 15-kHz IntraLase femtosecond laser on corneal endothelium. METHODS: In a prospective, single-center clinical trial, 138 patients (mean age: 32.0±7.1 years [range: 21 to 42 years]) underwent femtosecond LASIK for the correction of myopia −0.75 to −9.00 diopters (D) and cylinder up to 3.25 D. Patients were divided into two groups: contact lens group (n=76) and non-contact lens group (n=62). Pre- and 12-month postoperative specular microscopy of the central corneal endothelium was performed. The integrity of the central endothelium was assessed in terms of endothelial cell density and percentage of hexagonality. RESULTS: In the contact lens gro…
Collagen copolymer posterior chamber phakic intraocular lens for hyperopia correction: three-year follow-up.
2013
Purpose To assess the efficacy, predictability, safety, and stability of the Visian V3 Implantable Collamer Lens posterior chamber phakic intraocular lens (PC pIOL) for moderate to high hyperopia. Setting Private clinic, Oviedo, Spain. Design Prospective nonrandomized clinical study. Methods The uncorrected (UDVA) and corrected (CDVA) distance visual acuities, manifest refraction, endothelial cell density, intraocular pressure (IOP), central vault, and adverse events were evaluated for 3 years postoperatively. Results The study comprised 73 eyes of 44 patients. The mean spherical equivalent decreased from +4.84 diopters (D) ± 1.6 (SD) (range +1.00 to +7.75 D) preoperatively to −0.13 ± 0.39 …
Peripheral corneal thickness and associated factors - results from the population-based German Gutenberg Health Study.
2021
PURPOSE Changes in peripheral corneal thickness are described in various corneal diseases such as corneal ectasia. However, few data exist describing the increase in corneal thickness from central to peripheral and reporting the normal distribution of corneal thickness in rings around the corneal centre. The aim of this study was to report these cornea characteristics and investigate associated factors in a population-based setting. METHODS The Gutenberg Health Study is a prospective, population-based study examining participants in a 5-year follow-up (age range 40-80 years) using Scheimpflug imaging. Corneal thickness was assessed in each participant at the apex, as well as in the corneal …