Search results for "correction"
showing 10 items of 601 documents
"Table 27" of "Measurement of the inclusive jet cross-section in p anti-p collisions at s**(1/2) =1.96-TeV"
1970
Correction factors for hadronization, underlying event and total non-perturbative effects for the absolute value of the jet rapidity in the range 1.6 to 2.0.
"Table 17" of "Measurement of the inclusive jet cross-section in p anti-p collisions at s**(1/2) =1.96-TeV"
1970
Correction factors for hadronization, underlying event and total non-perturbative effects for the absolute value of the jet rapidity in the range 0.8 to 1.2.
"Table 32" of "Measurement of the inclusive jet cross-section in p anti-p collisions at s**(1/2) =1.96-TeV"
1970
Correction factors for hadronization, underlying event and total non-perturbative effects for the absolute value of the jet rapidity in the range 2.0 to 2.4.
hOA-DN30: a highly effective humanized single-arm MET antibody inducing remission of ‘MET-addicted’ cancers
2022
Abstract Background The tyrosine kinase receptor encoded by the MET oncogene is a major player in cancer. When MET is responsible for the onset and progression of the transformed phenotype (MET-addicted cancers), an efficient block of its oncogenic activation results in potent tumor growth inhibition. Methods Here we describe a molecular engineered MET antibody (hOA-DN30) and validate its pharmacological activity in MET-addicted cancer models in vitro and in vivo. Pharmacokinetics and safety profile in non-human primates have also been assessed. Results hOA-DN30 efficiently impaired MET activation and the intracellular signalling cascade by dose and time dependent removal of the receptor fr…
Relating Hyperspectral Airborne Data to Ground Measurements in a Complex and Discontinuous Canopy
2015
The work described in this paper is aimed at validating hyperspectral airborne reflectance data collected during the Regional Experiments For Land-atmosphere EXchanges (REFLEX) campaign. Ground reflectance data measured in a vineyard were compared with airborne reflectance data. A sampling strategy and subsequent ground data processing had to be devised so as to capture a representative spectral sample of this complex crop. A linear model between airborne and ground data was tried and statistically tested. Results reveal a sound correspondence between ground and airborne reflectance data (R2 > 0.97), validating the atmospheric correction of the latter.
New fitting scheme to obtain effective potential from Car-Parrinello molecular dynamics simulations: Application to silica
2008
A fitting scheme is proposed to obtain effective potentials from Car-Parrinello molecular dynamics (CPMD) simulations. It is used to parameterize a new pair potential for silica. MD simulations with this new potential are done to determine structural and dynamic properties and to compare these properties to those obtained from CPMD and a MD simulation using the so-called BKS potential. The new potential reproduces accurately the liquid structure generated by the CPMD trajectories, the experimental activation energies for the self-diffusion constants and the experimental density of amorphous silica. Also lattice parameters and elastic constants of alpha-quartz are well-reproduced, showing th…
The ARF GAPs ELMOD1 and ELMOD3 act at the Golgi and cilia to regulate ciliogenesis and ciliary protein traffic
2022
ELMODs are a family of three mammalian paralogs that display GTPase activating protein (GAP) activity towards a uniquely broad array of ADP-ribosylation factor (ARF) family GTPases that includes ARF-like (ARL) proteins. ELMODs are ubiquitously expressed in mammalian tissues, highly conserved across eukaryotes, and ancient in origin, being present in the last eukaryotic common ancestor. We described functions of ELMOD2 in immortalized mouse embryonic fibroblasts (MEFs) in the regulation of cell division, microtubules, ciliogenesis, and mitochondrial fusion. Here, using similar strategies with the paralogs ELMOD1 and ELMOD3, we identify novel functions and locations of these cell regulators a…
True vertical validation in facial orthognathic surgery planning
2013
Objectives: To validate the effectiveness of the original standards of True Vertical (TV) Subnasal Line in orthognatic surgery planning. The present study evaluates the changes occurring in patients with skeletal Class II alterations programmed for orthognathic surgery with a view to improving their facial profile. Study design: We showed a series of black profiles (composed by a first control group of subjects with normal occlusion, and another two additional groups comprised patients before –Group 2- and after orthognatic surgical correction of Class II malocclusion -Group 3-) for three groups of observers (orthodontists, surgeons and laypeople). The facial images became black silhouettes…
On the Trustworthiness of Error-Correcting Codes
2007
The use of error-correcting codes protects data against accidental or intentional errors, but to what extent can a decoded message be trusted? To answer this question, one has to take the role of the receiver. First, the maximum number of errors Lambda acceptable for decoding is fixed. With the weight distribution, the probability of false decoding can be calculated, conditioned on such a Lambda-bounded strategy. This probability is a monotonously increasing function in the channel error probability p and in the maximum number of accepted errors Lambda. Therefore, pure error detection is more trustworthy than error correction. Moreover, for sufficiently small p, codes with the lexicographic…
Incomplete Charge Collection at Inter-Pixel Gap in Low- and High-Flux Cadmium Zinc Telluride Pixel Detectors.
2022
The success of cadmium zinc telluride (CZT) detectors in room-temperature spectroscopic X-ray imaging is now widely accepted. The most common CZT detectors are characterized by enhanced-charge transport properties of electrons, with mobility-lifetime products μeτe > 10−2 cm2/V and μhτh > 10−5 cm2/V. These materials, typically termed low-flux LF-CZT, are successfully used for thick electron-sensing detectors and in low-flux conditions. Recently, new CZT materials with hole mobility-lifetime product enhancements (μhτh > 10−4 cm2/V and μeτe > 10−3 cm2/V) have been fabricated for high-flux measurements (high-flux HF-CZT detectors).…