Search results for "ddc:"
showing 10 items of 3080 documents
Vacuum correlators at short distances from lattice QCD
2021
Non-perturbatively computing the hadronic vacuum polarization at large photon virtualities and making contact with perturbation theory enables a precision determination of the electromagnetic coupling at the $Z$ pole, which enters global electroweak fits. In order to achieve this goal ab initio using lattice QCD, one faces the challenge that, at the short distances which dominate the observable, discretization errors are hard to control. Here we address challenges of this type with the help of static screening correlators in the high-temperature phase of QCD, yet without incurring any bias. The idea is motivated by the observations that (a) the cost of high-temperature simulations is typica…
Measurement of the Inclusive NuMu Charged Current Cross Section on Carbon in the Near Detector of the T2K Experiment
2013
T2K has performed the first measurement of nu(mu) inclusive charged current interactions on carbon at neutrino energies of similar to 1 GeV where the measurement is reported as a flux-averaged double differential cross section in muon momentum and angle. The flux is predicted by the beam Monte Carlo and external data, including the results from the NA61/SHINE experiment. The data used for this measurement were taken in 2010 and 2011, with a total of 10.8 x 10(19) protons-on-target. The analysis is performed on 4485 inclusive charged current interaction candidates selected in the most upstream fine-grained scintillator detector of the near detector. The flux-averaged total cross section is (…
The FIRST experiment at GSI
2012
The FIRST (Fragmentation of Ions Relevant for Space and Therapy) experiment at the SIS accelerator of GSI laboratory in Darmstadt has been designed for the measurement of ion fragmentation cross-sections at different angles and energies between 100 and 1000 MeV/nucleon. Nuclear fragmentation processes are relevant in several fields of basic research and applied physics and are of particular interest for tumor therapy and for space radiation protection applications. The start of the scientific program of the FIRST experiment was on summer 2011 and was focused on the measurement of 400 MeV/nucleon 12C beam fragmentation on thin (8 mm) graphite target. The detector is partly based on an alread…
First intense isotopic titanium-50 beam using MIVOC method
2012
Abstract An organometallic compound isotopically enriched in titanium-50 has been successfully used for the first time to produce intense ion beams with an ECR ion source by means of the MIVOC method. After some fruitful tests performed with compounds produced at IPHC Strasbourg with natural titanium, enriched organometallic titanium compound was produced successfully, beam extracted from ECR ion sources and accelerated through a K = 130 MeV cyclotron to an energy of 242 MeV. This isotopic 50 Ti 11 + beam was used for the first time in three week-experiment with typical MIVOC stable operating conditions. After optimization, up to 19.4 μA of titanium-50 in charge state 11 + could be extracte…
Electronic Structure of Lr+ (Z = 103) from Ab Initio Calculations
2022
Atoms 10(2), 48 (2022). doi:10.3390/atoms10020048
Ultrafast Dynamics of Magnetic Domain Structures Probed by Coherent Free-Electron Laser Light
2013
Synchrotron radiation news 26(6), 27 - 32 (2013). doi:10.1080/08940886.2013.850384
MeV ion beam lithography of biocompatible halogenated Parylenes using aperture masks
2015
Parylenes are poly(p-xylylene) polymers that are widely used as moisture barriers and in biomedicine because of their good biocompatibility. We have investigated MeV ion beam lithography using 16O+ ions for writing defined patterns in Parylene-C, which is evaluated as a coating material for the Cochlear Implant (CI) electrode array, a neuroprosthesis to treat some forms of deafness. Parylene-C and -F on silicon and glass substrates as well as 50 μm thick PTFE were irradiated to different fluences (1×1013-1×10161×1013-1×1016 1 MeV 16O+ ions cm−2) through aperture masks under high vacuum and a low pressure (<10−3 mbar) oxygen atmosphere. Biocompatibility of the irradiated and unirradiated …
Influence of complex impurity centres on radiation damage in wide-gap metal oxides
2016
Different mechanisms of radiation damage of wide-gap metal oxides as well as a dual influence of impurity ions on the efficiency of radiation damage have been considered on the example of binary ionic MgO and complex ionic–covalent $Lu_{3}Al_{5}O_{12}$ single crystals. Particular emphasis has been placed on irradiation with $\sim$2 GeV heavy ions ($^{197}Au, ^{209}Bi, ^{238}U$, fluence of 10$^{12}$ ions/cm$^{2}$) providing extremely high density of electronic excitations within ion tracks. Besides knock-out mechanism for Frenkel pair formation, the additional mechanism through the collapse of mobile discrete breathers at certain lattice places (e.g., complex impurity centres) leads to the c…
Performance of Dye and Ti:sapphire laser systems for laser ionization and spectroscopy studies at S3
2020
The novel and sensitive In-Gas Laser Ionization Spectroscopy (IGLIS) technique enables high-precision laser spectroscopy of the heaviest elements and isotopes very far from stability that are produced in fusion-evaporation reactions at in-flight separators. Powerful and dedicated laser systems are required in these facilities to realize in-gas jet laser spectroscopy with optimal spectral resolution and efficiency. The performance with respect to the requirements for IGLIS studies at the low energy front-end of the Super Separator Spectrometer (S3) at GANIL, France, of Dye and Ti:sapphire laser systems is investigated. In addition, a number of specific experimental cases on key isotopes of t…
Enhancement of the laser-driven proton source at PHELIX
2020
High power laser science and engineering 8, e24 (2020). doi:10.1017/hpl.2020.23