Search results for "desi"

showing 10 items of 6638 documents

Direct-acting antiviral agents and risk of hepatocellular carcinoma: is it still a clinical dilemma?

2019

Direct-acting antivirals (DAAs) revolutionised the treatment of chronic HCV-related disease achieving high rates of sustained virological response (SVR), also in more advanced patients, with a good safety profile and a proven positive effect on the reduction of risk of HCC occurrence. Nevertheless, patients with an history of successfully treated early HCC were initially excluded from pivotal trials. Although some initial retrospective studies, affected by several methodological issues, raised concerns regarding a possible harmful effect on the risk of HCC recurrence after antiviral therapy, more recent prospective studies and meta-analyses provided evidence that risk of HCC recurrence afte…

Antiviral AgentSurvival RateCarcinoma HepatocellularRisk FactorsEndpoint DeterminationLiver NeoplasmResearch DesignRisk FactorLiver NeoplasmsHumansHepatitis C ChronicAntiviral AgentsHuman
researchProduct

CardioPulse: developments in the treatment of aortic aneurysms in 2014

2015

Since the introduction of EndoVascular Aortic Repair (EVAR) for the treatment of abdominal aortic aneurysms (AAA) more than 20 years ago, the technique has evolved rapidly, from tubular grafts for fairly simple abdominal aortic anatomy, to bifurcated, fenestrated, branched, or parallel grafts for complex aortic aneurysms, no longer confined to the infrarenal abdominal aorta.

Aortic Aneurysm ThoracicAortic RuptureEndovascular ProceduresBiomedical Technology610 Medicine & healthEquipment DesignSettore MED/22 - Chirurgia Vascolare2705 Cardiology and Cardiovascular MedicineBlood Vessel Prosthesis10020 Clinic for Cardiac SurgeryBlood Vessel Prosthesis ImplantationHumansaortic aneurysmAortic Aneurysm Abdominal
researchProduct

Thoracic Endovascular Aortic Repair (TEVAR) for the treatment of aortic diseases: a position statement from the European Association for Cardio-Thora…

2012

Thoracic endovascular aortic repair (TEVAR) is an emerging treatment modality, which has been rapidly embraced by clinicians treating thoracic aortic disease.1–4 Fundamentally, it is a far less invasive approach than open surgery and its availability and relative ease of application has changed and extended management options in thoracic aortic disease, including in those patients deemed unfit or unsuitable for open surgery. In the operating room, this requires considerable perceptual, cognitive and psychomotor demands on the operators. The dramatic expansion of TEVAR activity has necessarily prompted a requirement to systematically consider the indications, appropriateness, limitations and…

Aortic archEndoleakMedizinAnastomotic LeakAorta ThoracicChest painPatient Care PlanningAortic aneurysmPostoperative ComplicationsIntraoperative ComplicationsBrain DiseasesEndovascular ProceduresAngiographyEquipment DesignGeneral MedicineTreatment OutcomeCardiothoracic surgeryDescending aortacardiovascular systemCardiologyStentsmedicine.symptomCardiology and Cardiovascular MedicinePulmonary and Respiratory Medicinemedicine.medical_specialtyConsensusAortic DiseasesPerioperative CareSpinal Cord DiseasesBlood Vessel Prosthesis ImplantationAneurysmBlood vessel prosthesismedicine.arteryInternal medicineMonitoring IntraoperativemedicineHumansAortaAortic Aneurysm Thoracicbusiness.industryContraindicationsPatient SelectionVascular System Injuriesmedicine.diseaseSurgeryBlood Vessel ProsthesisAortic DissectionSurgerybusinessTomography X-Ray ComputedEchocardiography TransesophagealEuropean Journal of Cardio-Thoracic Surgery
researchProduct

Computer Modeling for the Prediction of Thoracic Aortic Stent Graft Collapse

2011

OBJECTIVE: To assess the biomechanical implications of excessive stent protrusion into the aortic arch in relation to thoracic aortic stent graft (TASG) collapse by simulating the structural load and quantifying the fluid dynamics on the TASG wall protrusion extended into a model arch. METHODS: One-way coupled fluid-solid interaction analyses were performed to investigate the flow-induced hemodynamic and structural loads exerted on the proximal protrusion of the TASG and aortic wall reconstructed from a patient who underwent traumatic thoracic aortic injury repair. Mechanical properties of a Gore TAG thoracic endoprosthesis (W. L. Gore and Assoc, Flagstaff, Ariz) were assessed via experimen…

Aortic archMalemedicine.medical_specialtyAortographymedicine.medical_treatmentHemodynamicsAorta ThoracicFOS: Medical engineeringProsthesis DesignAortographyBlood Vessel Prosthesis ImplantationImaging Three-DimensionalBlood vessel prosthesismedicine.arteryMaterials TestingmedicineHumansComputer Simulationthoracic aortic stent graft (TASG)Aortamedicine.diagnostic_testbusiness.industryEndovascular ProceduresHemodynamicsModels CardiovascularStentSettore ING-IND/34 - Bioingegneria Industrialenutritional and metabolic diseases90399 Biomedical Engineering not elsewhere classifiedCurvatures of the stomachSurgeryBiomechanical PhenomenaBlood Vessel ProsthesisProsthesis FailureEquipment Failure AnalysisRegional Blood FlowRadiographic Image Interpretation Computer-AssistedStentslipids (amino acids peptides and proteins)SurgeryStress Mechanicalbiological phenomena cell phenomena and immunitybusinessNuclear medicineTomography X-Ray ComputedCardiology and Cardiovascular MedicinePerfusionAlgorithmsJournal of Vascular Surgery
researchProduct

An In Vitro Phantom Study on the Role of the Bird-Beak Configuration in Endograft Infolding in the Aortic Arch.

2015

Purpose: To assess endograft infolding for excessive bird-beak configurations in the aortic arch in relation to hemodynamic variables by quantifying device displacement and rotation of oversized stent-grafts deployed in a phantom model. Methods: A patient-specific, compliant, phantom pulsatile flow model was reconstructed from a patient who presented with collapse of a Gore TAG thoracic endoprosthesis. Device infolding was measured under different flow and pressure conditions for 3 protrusion extensions (13, 19, and 24 mm) of the bird-beak configuration resulting from 2 TAG endografts with oversizing of 11% and 45%, respectively. Results: The bird-beak configuration with the greatest protr…

Aortic archModels AnatomicRadiology Nuclear Medicine and ImagingTime FactorsFlow modelPulsatile flowEndograftStent-graft oversizingAorta Thoracic030204 cardiovascular system & hematologyRotation0302 clinical medicineForeign-Body MigrationStentThoracic aortaBird-beak configurationmedicine.diagnostic_testEndovascular ProceduresGraft Occlusion VascularModels CardiovascularAnatomyIn vitro experimentProsthesis FailureBlood Vessel ProsthesiTreatment OutcomePulsatile FlowPatient-specific modelStentsCardiology and Cardiovascular MedicineHumanAortographyTime FactorThoracic endovascular aortic repairProsthesis DesignAortographyImaging phantom03 medical and health sciencesBlood Vessel Prosthesis ImplantationBlood vessel prosthesismedicine.arterymedicineHumansDisplacement (orthopedic surgery)HemodynamicEndovascular Procedurebusiness.industryHemodynamicsDisplacementStent-graft infoldingBlood Vessel ProsthesisSurgerybusinessTomography X-Ray Computed030217 neurology & neurosurgeryStent-graft collapseJournal of endovascular therapy : an official journal of the International Society of Endovascular Specialists
researchProduct

Treatment of isolated ascending aortic aneurysm by off-pump epiaortic wrapping is safe and durable.

2016

OBJECTIVES: Isolated ascending aortic aneurysm (iAA) is usually treated by open graft repair requiring sternotomy, cardiopulmonary bypass (CPB) and cardioplegia. This approach carries significant mortality in older patients or those presenting with comorbidities. We report an original series of patients presenting with iAA and treated with epiaortic wrapping by using a synthetic mesh. This less invasive aortic repair technique allows reducing the aortic diameter to a predefined value and is performed without CPB. METHODS: Data from patients presenting with an iAA and treated with the wrapping technique (WT) by polypropylene/polyester mesh from November 2006 to July 2015 were collected. The …

Aortic valveMaleTime Factors030204 cardiovascular system & hematologySettore MED/22 - Chirurgia Vascolarelaw.inventionAortic aneurysm0302 clinical medicinelawAorta10042 Clinic for Diagnostic and Interventional RadiologyMedicine (all)Middle Aged2746 Surgerymedicine.anatomical_structureTreatment OutcomeWrapping girdlingFemaleCardiology and Cardiovascular MedicineVascular Surgical ProceduresPulmonary and Respiratory Medicinemedicine.medical_specialtyOffOff-pump610 Medicine & healthProsthesis Design2705 Cardiology and Cardiovascular MedicineGraft repair03 medical and health sciencesAneurysmBlood vessel prosthesismedicine.arteryAscending aortamedicineCardiopulmonary bypassHumansAortic valve insufficiency; Ascending aorta; Graft repair; Mesh (polypropylene/polyester); Off-pump; Wrapping girdling; Surgery; Medicine (all); Pulmonary and Respiratory Medicine; Cardiology and Cardiovascular MedicineAgedRetrospective StudiesAortaAortic Aneurysm Thoracicbusiness.industryPerioperativemedicine.diseaseSternotomySurgeryBlood Vessel Prosthesis030228 respiratory systemAortic valve insufficiency2740 Pulmonary and Respiratory MedicinepumpSurgeryAscending aortaMesh (polypropylene/polyester)businessFollow-Up StudiesInteractive cardiovascular and thoracic surgery
researchProduct

Binary Hamming codes and Boolean designs

2021

AbstractIn this paper we consider a finite-dimensional vector space $${\mathcal {P}}$$ P over the Galois field $${\text {GF}}(2),$$ GF ( 2 ) , and the family $${\mathcal {B}}_k$$ B k (respectively, $${\mathcal {B}}_k^*$$ B k ∗ ) of all the k-sets of elements of $$\mathcal {P}$$ P (respectively, of $${\mathcal {P}}^*= {\mathcal {P}} \setminus \{0\}$$ P ∗ = P \ { 0 } ) summing up to zero. We compute the parameters of the 3-design $$({\mathcal {P}},{\mathcal {B}}_k)$$ ( P , B k ) for any (necessarily even) k, and of the 2-design $$({\mathcal {P}}^{*},{\mathcal {B}}_k^{*})$$ ( P ∗ , B k ∗ ) for any k. Also, we find a new proof for the weight distribution of the binary Hamming code. Moreover, we…

Applied Mathematics010102 general mathematicsGalois theoryZero (complex analysis)0102 computer and information sciencesAutomorphism01 natural sciencesComputer Science ApplicationsCombinatoricsBlock designs Hamming codes Permutation automorphisms Weight distribution Subset sum problemPermutation010201 computation theory & mathematicsWeight distributionSettore MAT/03 - Geometria0101 mathematicsHamming weightHamming codeVector spaceMathematics
researchProduct

Our Friend and Mathematician Karl Strambach

2020

This paper is dedicated to Karl Strambach on the occasion of his 80th birthday. Here we want to describe our work with Prof. Karl Strambach.

Applied Mathematicsimprimitive groupGrünwald spaces shells of curve010102 general mathematicsgroup theoryArt historyloop01 natural sciencescomplex curveLie group010101 applied mathematicsHjelmslev geometryMathematics (miscellaneous)Work (electrical)Mathematikalgebraic groupaffine connectionSettore MAT/03 - Geometria0101 mathematicsMathematicsBiographiebibliographiegeodesics
researchProduct

Activity-Centered Design: An Appropriation Issue

2011

When designing workplace computer systems one must take human activity into account. It has become standard practice to approach this issue through user-centered design. The aim of this paper is to stimulate thought on activity-centered design and to propose the concept of appropriation as a fundamental principle of this design approach. This orientation aims to take into consideration the constituent function of tools during conception. We will take the design of computer systems dedicated to customer relations as an example.

AppropriationKnowledge managementActivity-centered designProcess managementOrientation (mental)business.industryComputer sciencemedia_common.quotation_subjectCustomer relationship managementbusinessFunction (engineering)media_common
researchProduct

Using tools effectively despite defective hand posture: A single-case study.

2019

Apraxia, a cognitive disorder of motor control, can severely impair transitive actions (object-related) and may lead to action errors (e.g., rubbing a hammer on a nail instead of pounding it) and hand posture errors (e.g., grasping a tool in a wrong way). Here, we report a rare observation of a left-handed patient, left-lateralized for language, who developed a severe apraxia following a right brain lesion. Interestingly the patient showed a significant number of hand posture errors, while she perfectly demonstrated the actual use of tools. This case stressed the predictions made by the current theories of tool use. According to the manipulation-based approach, the hand posture errors shoul…

ApraxiasCognitive NeurosciencePostureExperimental and Cognitive PsychologySingle-subject designApraxia050105 experimental psychologyLateralization of brain functionFunctional Laterality03 medical and health sciences0302 clinical medicinemedicineHumans0501 psychology and cognitive sciencesAssociation (psychology)Transitive relationHand Strength05 social sciencesMotor controlBrainmedicine.diseaseHandNeuropsychology and Physiological PsychologyAction (philosophy)FemalePsychologyNeurocognitive030217 neurology & neurosurgeryPsychomotor PerformanceCognitive psychologyCortex; a journal devoted to the study of the nervous system and behavior
researchProduct