Search results for "detector"
showing 10 items of 3491 documents
Limits on the diffuse flux of ultra-high energy neutrinos using the Pierre Auger Observatory
2012
Abstract The surface detector array of the Pierre Auger Observatory is sensitive to ultra-high energy neutrinos in the cosmic radiation. These particles can interact close to ground, both through charged and neutral currents in the atmosphere (down-going) and, for tau neutrinos, through the Earth-skimming mechanism (up-going) where a tau lepton is produced in the Earth's crust that can emerge and decay in the atmosphere. Both types of neutrino-induced events produce an inclined shower that can be identified by the presence of a broad time structure of signals in the water-Cherenkov detectors. Using data collected from the surface detector array of the Pierre Auger Observatory, we present th…
An edge-driven 3D region-growing approach for upper airway morphology and volume evaluation in patients with Pierre Robin sequence
2015
Abstract: Pierre Robin sequence (PRS) is a pathological condition responsible for a sequence of clinical events, such as breathing and feeding difficulties, that must be addressed to give the patient at least a chance to survive. By using medical imaging techniques, in a non-intrusive way, the surgeon has the opportunity to obtain 3D views, reconstruction of the regions of interest (ROIs), useful to increase understanding of the PRS patient’s condition. In this paper, a semi-automatic approach for segmentation of the upper airways is proposed. The implemented approach uses an edge-driven 3D region-growing algorithm to segment ROIs and 3D volume-rendering technique to reconstruct the 3D mode…
Development of a low-cost piezo film-based knock sensor
2003
It is well known that spark advance is a key parameter in spark ignition engine management. Increasing fuel cost and emission regulation strictness require a higher engine efficiency, which can be improved by an accurate regulation of the spark advance. Under high load conditions, an optimal spark advance choice leads the engine to run next to the knock limit, so the management and control system needs to be equipped with a knock sensor in order to preserve the engine from damage. The authors developed a low-cost knock sensor whose sensing element is a thin washer of polyvinylidine fluoride (PVDF), a fluoropolymer characterized by a great piezoelectric e ect if polarized. The sensor has be…
A low-level spectrometer with a planar low-energy HPGe: shielding arrangement tests and system performance for 210Pb determination in air filter samp…
2001
A system for low-energy photon spectrometry using a planar germanium detector with appropriate specifications is presented. A spectrometric background investigation has been carried out with various detector shielding arrangements. The characteristics of the system for measurements of 210Pb in air-particulate matter on filters have been determined.
Applying Artificial Intelligence Methods to Detect and Classify Fish Calls from the Northern Gulf of Mexico
2021
Passive acoustic monitoring is a method that is commonly used to collect long-term data on soniferous animal presence and abundance. However, these large datasets require substantial effort for manual analysis
INTEGRAL/SPI ground calibration
2003
Three calibration campaigns of the spectrometer SPI have been performed before launch in order to determine the instrument characteristics, such as the effective detection area, the spectral resolution and the angular resolution. Absolute determination of the effective area has been obtained from simulations and measurements. At 1 MeV, the effective area is 65 cm^2 for a point source on the optical axis, the spectral resolution ~2.3 keV. The angular resolution is better than 2.5 deg and the source separation capability about 1 deg. Some temperature dependant parameters will require permanent in-flight calibration.
Observation of the cosmic ray moon shadowing effect with the ARGO-YBJ experiment
2011
Cosmic rays are hampered by the Moon and a deficit in its direction is expected (the so-called Moon shadow). The Moon shadow is an important tool to determine the performance of an air shower array. Indeed, the westward displacement of the shadow center, due to the bending effect of the geomagnetic field on the propagation of cosmic rays, allows the setting of the absolute rigidity scale of the primary particles inducing the showers recorded by the detector. In addition, the shape of the shadow permits to determine the detector point spread function, while the position of the deficit at high energies allows the evaluation of its absolute pointing accuracy. In this paper we present the obser…
Angular spreading measurements using MeV ion microscopes
2013
Abstract The sharpness of MeV ion microscope images is governed by small-angle scattering and associated lateral spreading of the ion beam in the sample. We have investigated measurement of the half-angle of the angular spreading distribution by characterising the image blurring in direct-Scanning Transmission Ion Microscopy (direct-STIM). In these tests Mylar™ foils of 0.5–6 μm were used to induce angular spreading. Images were taken of an electron microscope grid using 2 MeV protons with, and without, the foils in the beam path. The blurring was measured by fitting the width of a circular Gaussian point spread function to the images with and without the foil in position. The results show …
The ATHENA X-ray Integral Field Unit (X-IFU)
2018
Event: SPIE Astronomical Telescopes + Instrumentation, 2018, Austin, Texas, United States.
On magnetic guidance of charged particles
2016
High precision beta decay experiments with polarized neutrons, employing magnetic guiding fields for the decay electrons in combination with energy dispersive detectors, initiated detailed studies of the point spread function (PSF) for homogeneous magnetic fields. A PSF describes the radial probability distribution of mono-energetic electrons at the detector plane which were emitted from a point-like source. With regard to accuracy considerations for high-precision experiments unwanted singularities occur as function of the radial detector coordinate which have recently been discussed in detail by Dubbers (2015) [3]. In the present article mathematical inconsistencies in the approximations …