Detection of lung cancer bio-markers in human breath using a micro-fabricated air analyzer
2015
International audience; The analysis of volatile organic compounds (VOCs) that are linked to lung cancer is a very promising way in medical diagnostics because it is non-invasive and potentially inexpensive. In that sense, a silicon micro-analytical platform consisting of a three-dimensional micro-preconcentrator coupled to a silicon spiral gas chromatographic micro-column was built. A metal oxide-based gas sensor acted as a miniaturized gas detector. This system allowed selective detection of VOCs at the sub-ppm level. The present study is focused first on the chromatographic air analyzer fabrication and second on the selection of an appropriate adsorbent. Various adsorbents such as activa…
Single-Hemisphere Photoelectron Momentum Microscope With Time-of-Flight Recording
2020
Photoelectron momentum microscopy is an emerging powerful method for angle-resolved photoelectron spectroscopy (ARPES), especially in combination with imaging spin filters. These instruments record kx-ky images, typically exceeding a full Brillouin zone. As energy filters double-hemispherical or time-of-flight (ToF) devices are in use. Here we present a new approach for momentum mapping of the full half-space, based on a single hemispherical analyzer (path radius 225 mm). Excitation by an unfocused He lamp yielded an energy resolution of 7.7 meV. The performance is demonstrated by k-imaging of quantum-well states in Au and Xe multilayers. The alpha-square-aberration term (alpha: entrance an…
A high-Q superconducting toroidal medium frequency detection system with a capacitively adjustable frequency range >180 kHz
2022
We describe a newly developed polytetrafluoroethylene/copper capacitor driven by a cryogenic piezoelectric slip-stick stage and demonstrate with the chosen layout cryogenic capacitance tuning of ≈60 pF at ≈10 pF background capacitance. Connected to a highly sensitive superconducting toroidal LC circuit, we demonstrate tuning of the resonant frequency between 345 and 685 kHz, at quality factors Q > 100 000. Connected to a cryogenic ultra low noise amplifier, a frequency tuning range between 520 and 710 kHz is reached, while quality factors Q > 86 000 are achieved. This new device can be used as a versatile image current detector in high-precision Penning-trap experiments or as …
A reservoir trap for antiprotons
2015
We have developed techniques to extract arbitrary fractions of antiprotons from an accumulated reservoir, and to inject them into a Penning-trap system for high-precision measurements. In our trap-system antiproton storage times > 1.08 years are estimated. The device is fail-safe against power-cuts of up to 10 hours. This makes our planned comparisons of the fundamental properties of protons and antiprotons independent from accelerator cycles, and will enable us to perform experiments during long accelerator shutdown periods when background magnetic noise is low. The demonstrated scheme has the potential to be applied in many other precision Penning trap experiments dealing with exotic p…
Calibration of high voltages at the ppm level by the difference of $^{83\mathrm{m}}$Kr conversion electron lines at the KATRIN experiment
2018
The neutrino mass experiment KATRIN requires a stability of 3 ppm for the retarding potential at − 18.6 kV of the main spectrometer. To monitor the stability, two custom-made ultra-precise high-voltage dividers were developed and built in cooperation with the German national metrology institute Physikalisch-Technische Bundesanstalt (PTB). Until now, regular absolute calibration of the voltage dividers required bringing the equipment to the specialised metrology laboratory. Here we present a new method based on measuring the energy difference of two [superscript 83m]Kr conversion electron lines with the KATRIN setup, which was demonstrated during KATRIN’s commissioning measurements in July 2…
Reduction of stored-particle background by a magnetic pulse method at the KATRIN experiment
2018
Arenz, M., et al. “Reduction of Stored-Particle Background by a Magnetic Pulse Method at the KATRIN Experiment.” The European Physical Journal C, vol. 78, no. 9, Sept. 2018. © 2018 The Authors
Suppression of Penning discharges between the KATRIN spectrometers
2020
The KArlsruhe TRItium Neutrino experiment (KATRIN) aims to determine the effective electron (anti)neutrino mass with a sensitivity of $0.2\textrm{ eV/c}^2$ (90$\%$ C.L.) by precisely measuring the endpoint region of the tritium $\beta$-decay spectrum. It uses a tandem of electrostatic spectrometers working as MAC-E (magnetic adiabatic collimation combined with an electrostatic) filters. In the space between the pre-spectrometer and the main spectrometer, an unavoidable Penning trap is created when the superconducting magnet between the two spectrometers, biased at their respective nominal potentials, is energized. The electrons accumulated in this trap can lead to discharges, which create a…
Gamma-induced background in the KATRIN main spectrometer
2019
The KATRIN experiment aims to measure the effective electron antineutrino mass $$m_{\overline{\nu }_e}$$ mν¯e with a sensitivity of $${0.2}\,{\hbox {eV}/\hbox {c}^2}$$ 0.2eV/c2 using a gaseous tritium source combined with the MAC-E filter technique. A low background rate is crucial to achieving the proposed sensitivity, and dedicated measurements have been performed to study possible sources of background electrons. In this work, we test the hypothesis that gamma radiation from external radioactive sources significantly increases the rate of background events created in the main spectrometer (MS) and observed in the focal-plane detector. Using detailed simulations of the gamma flux in the e…
Salient Spin Images: A Descriptor for 3D Object Recognition
2018
In the last decades a wide range of algorithms have been devoted to recognize 3D free-from objects under real conditions such as occlusions, clutters, rotation, scale and translation. Spin image is one of these algorithms known to be robust to rotation, translation, occlusions up to 70% and clutters up to 60%, but still suffer from scaling, resolution changes and it is time consuming. In this paper we present a novel approach based on spin images, called salient spin images (SSI). This method enhances spin images algorithm based on its limits. Particularly, it decreases significantly the complexity of the algorithm using DoG detector, it shows a higher performance due to the relevant locali…
Yttria-stabilized zirconia in-flight particle characteristics under vacuum plasma spray conditions
2009
This paper deals with the diagnostic yttria-stabilized zirconia (YSZ) in-flight particles in Vacuum Plasma Spray (VPS) process using an optical measurement device. Particle velocity, temperature and diameter were correlated to spray distance under a fixed chamber pressure of about 14 kPa. Experiments were carried out with a two-color pyrometer. Results show that correlations can be satisfactory described with linear relationships. Particle velocity and temperature decrease when increasing spray distance whereas particle diameter exhibits a linear increase with the spray distance.