Search results for "detector"
showing 10 items of 3491 documents
Design and performance of the prototype Schwarzschild-Couder telescope camera
2022
Journal of astronomical telescopes, instruments, and systems 8(01), 014007-1 (2022). doi:10.1117/1.JATIS.8.1.014007
Theoretical study of neutrino scattering off the stable even Mo isotopes at low and intermediate energies
2011
A systematic study of the cross sections of neutral-current neutrino scattering off the stable even Mo isotopes (mass number A = 92, 94, 96, 98, 100), at low and intermediate neutrino energies (E(nu) <= 130 MeV), is presented and discussed. The required wave functions for the initial (ground state) and all accessible final nuclear states are constructed in the context of the quasi-particle random-phase approximation (QRPA) and tested against data on the low-lying energy spectra of the isotopes in question. The individual contributions coming from the polar-vector and axial-vector components of the hadronic current for the coherent and incoherent channels of each isotope are investigated. Th…
Validation of a method for neutron dosimetry and spectrometry using neutron activation of metal discs
2009
A technique for neutron dosimetry and spectrometry based on neutron activation of different metal discs has been studied. After exposure to a neutron field, the radionuclides produced in the discs are detected using low-level gamma-ray spectrometry and the neutron spectrum is obtained using a spectrum unfolding technique. In order to validate the method, irradiation was performed in a well-characterised (252)Cf neutron reference field. Furthermore, the detector was used to determine the neutron fluence rate and spectrum at a storage place for MOX nuclear fuel. The results of the two measurements are reported and discussed.
Optical Properties of Irradiated Yttrium Aluminum Garnet
2012
The results of investigation of the photoluminescence (PL) and optical absorption of crystals Y3Al5O12(YAG) doped with different concentrations of manganese ions exposed to fast neutron irradiation and electron irradiation are presented. Photoluminescence spectra of YAG before neutron irradiation at T=80 K contain fine lines in orange region of spectrum, ascribed to Mn2+ ions in octahedral position. After irradiation band broadening is observed in the luminescence spectra of garnet crystals. Electron irradiation produced broad band with a complex structure related to Mn4+ ions. Exchange interaction between radiation defect and impurity ions during neutron irradiation and electron irradiatio…
The effect of oxygenation on the radiation hardness of silicon studied by surface photovoltage method
2002
The effect of oxygenation on the radiation hardness of silicon detectors was studied. Oxygen-enriched and standard float-zone silicon pin-diodes and oxidized samples were processed and irradiated with 15-MeV protons. After the irradiations, the surface photovoltage (SPV) method was applied to extract minority carrier diffusion lengths of the silicon samples. Adding oxygen to silicon was found to improve the radiation hardness of silicon. The effect was visible in minority carrier diffusion lengths as well as in reverse bias leakage currents. The suitability of SPV method for characterizing irradiated silicon samples was proved.
A measurement of the neutron to 199Hg magnetic moment ratio
2014
The neutron gyromagnetic ratio has been measured relative to that of the 199Hg atom with an uncertainty of 0.8 ppm. We employed an apparatus where ultracold neutrons and mercury atoms are stored in the same volume and report the result γn/γHg=3.8424574(30).
Annealing study of oxygenated and non-oxygenated float zone silicon irradiated with protons
2003
Abstract Introducing oxygen into the silicon material is believed to improve the radiation hardness of silicon detectors. In this study, oxygenated and non-oxygenated silicon samples were processed and irradiated with 15 MeV protons. In order to speed up the defect reactions after the exposure to particle radiation, the samples were heat treated at elevated temperatures. In this way, the long-term stability of silicon detectors in hostile radiation environment could be estimated. Current–voltage measurements and Surface Photovoltage (SPV) method were used to characterize the samples.
Dose calculation in biological samples in a mixed neutron-gamma field at the TRIGA reactor of the University of Mainz
2010
To establish Boron Neutron Capture Therapy (BNCT) for non-resectable liver metastases and for in vitro experiments at the TRIGA Mark II reactor at the University of Mainz, Germany, it is necessary to have a reliable dose monitoring system. The in vitro experiments are used to determine the relative biological effectiveness (RBE) of liver and cancer cells in our mixed neutron and gamma fi eld. We work with alanine detectors in combination with Monte Carlo simulations, where we can measure and characterize the dose. To verify our calculations we perform neutron fl ux measurements using gold foil activation and pin-diodes . Material and methods . When L- α -alanine is irradiated with ionizing …
The measurement of impurities in silicon for solar cell production
2012
The power conversion efficiency of solar cells is largely dependent on impurity levels in silicon. In the current investigations two sample preparation methods of silicon had been used before analysis - acid dissolution at atmospheric pressure and pressured microwave assisted technique. Quantification of impurities in solar silicon was done by inductively coupled plasma mass spectrometry and electrothermal atomic spectrometry. Microwave assisted dissolution of solar silicon was more effective compared to the traditional dissolution method on the hot plate, but complete dissolution of impurities and silicon matrix was achieved with a nitric and hydrofluoric acid mixture. The mass of solar si…
Twenty Years of Airborne Water Vapor and Total Water Measurements of a Diode Laser Based Photoacoustic Instruments
2020
We present relevant issues collected over twenty years of development and operation of an airborne water vapour / total water detector based on photoacoustic spectroscopy. The WaSulHygro instrument possesses high selectivity, short response time, and wide dynamic range, that are key requirements against trace gas measurement systems for applications in atmospheric sciences. Besides the major properties of WaSul-Hygro we discuss our efforts to develop a robust instruments that have proved its long-term reliability over the last fifteen years operating on-board a commercial aircraft within the framework of the CARIBIC project.2