Search results for "detectors"
showing 10 items of 2229 documents
Optical investigation of the OH− groups in the LiNbO3 doped by copper
2019
Doping ions and OH− groups absorption bands spatial profiles were investigated for the case of congruent LiNbO3 single crystal grown by Czochralski technique. Doping was performed after the crystal...
The Engineering of Hot Carbon Nanotubes with a Focused Electron Beam
2004
Single-wall and multiwall carbon nanotubes at high temperature are irradiated with the focused electron beam in an electron microscope. Nanotubes can be tailored with monolayer precision, and new morphologies of nanotubes are created. Atoms from layers of multiwall tubes can be removed and the tubes can be bent by a predefined angle. Bundles of single-wall tubes are transformed locally to multiwall tubes with coherent transition between the two modifications.
Positron lifetime measurements on neutron‐irradiated InP crystals
1996
Neutron‐irradiated InP single crystals have been investigated by positron‐lifetime measurements. The samples were irradiated with thermal neutrons at different fluences yielding concentrations for Sn‐transmuted atoms between 2×1015 and 2×1018 cm−3. The lifetime spectra have been analyzed into one exponential decay component. The mean lifetimes show a monotonous increase with the irradiation dose from 246 to 282 ps. The increase in the lifetime has been associated to a defect containing an Indium vacancy. Thermal annealing at 550 °C reduces the lifetime until values closed to those obtained for the as‐grown and conventionally doped InP crystals. navarrof@evalvx.ific.uv.es ; Jose.Ferrero@uv.es
Ion irradiation of carbon nanotubes encapsulating cobalt crystals
2008
Abstract The response of multi-walled carbon nanotubes encapsulating Co nanorods to ion irradiation was studied. The irradiation experiments with medium ion energies (40–500 keV) were carried out at high temperatures and combined with transmission electron microscopy and Raman characterization of the irradiated samples. Contrary to electron irradiation and high-energy (100 MeV) ion irradiation, we did not see accumulation of pressure inside irradiated nanotubes. We found that nanotubes with Co nanorods inside were transformed to amorphous carbon rods encapsulating Co clusters with typical diameters of 3–6 nm. As Co is magnetic, such one-dimensional composite systems could be used for variou…
The “accumulation effect” of positrons in the stack of foils, detected by measurements of the positron implantation profile
2013
The profiles of positrons implanted from the radioactive source 22Na into a stack of foils and plates are the subject of our experimental and theoretical studies. The measurements were performed using the depth scanning of positron implantation profile method, and the theoretical calculations using the phenomenological multi-scattering model (MSM). Several stacks consisting of silver, gold and aluminum foils, and titanium and germanium plates were investigated. We notice that the MSM describes well the experimental profiles; however when the stack consisting of silver and gold foils, the backscattering and linear absorption coefficients differ significantly from those reported in the litera…
Buckling of a coating strip of finite width bonded to elastic half-space
2008
AbstractA solution for buckling of a stiff strip of finite width bonded to a compliant elastic half-space and subjected to uniform axial compression is presented. Approximate semi-analytical and finite element solutions are obtained and compared with a two-dimensional case of a plate on elastic foundation. The comparison demonstrates that the two-dimensional solution can be applied to predict the buckling wavelength and critical compressive strain when the width of the strip is equal to or larger than the buckling wavelength. For narrow strips, the wavelength is smaller and critical strain is higher than that of a plate on foundation.
A Comparative Analysis of Some Theories and Finite Elements for Sandwich Plates and Shells
1998
In this paper we give a comparative analysis of the performance of some theories and finite elements for the calculation of composite sandwich plates and shells
Simplified Model for Compressive Behavior of Concrete Columns Strengthened by Steel Angles and Strips
2010
This paper presents an analytical model to determine the compressive response of concrete members, having a square transverse cross section and reinforced with steel angles at the corners and steel strips connecting the steel angles. The model evaluates the effects of transverse strips and steel angles on confinement pressures, including strength and buckling phenomena. Compressive response was evaluated in cases of directly and indirectly loaded elements. The data produced correlate well with available experimental data.
Development of Structured Scintillator Tiles for High-Granularity Calorimeters
2020
Calorimeters with a fine 3-D segmentation are considered to be a very promising technology for future high-energy physics experiments, since they provide in combination with particle flow algorithms excellent jet energy resolution and particle identification capabilities. Depending on the size, millions of individual channels consisting of a photosensor coupled to a scintillator tile have to be assembled. The usage of structured plastic scintillators with optically separated segments simplifies the mass production. We present the design, production, and performance of a 36 cm × 36 cm scintillator tile divided into 144 segments matching the geometry of the SiPM-based calorimeter frontend dev…
Development of a 3D CZT Spectrometer System with Digital Readout for Hard X/Gamma-Ray Astronomy
2019
We report on the development and of a complete X/γ rays detection system (10-1000 keV) based on CZT spectrometers with spatial resolution in three dimensions (3D) and a digital electronics acquisition chain. The prototype is made by packing four linear modules, each composed of one 3D CZT sensors. Each sensors is realized using a single spectroscopic graded CZT crystal of about 20×20×5 mm3. An electrode structure consisting of 12 collecting anodes with a pitch of 1.6 mm and 3 drift strips between each pair of anodes for 48 strips (0.15 mm wide) on the anodic side was adopted. The cathode is made of 10 strips with a pitch of 2 mm and orthogonal to anode side strips. Since the reading of the …