Search results for "device"
showing 10 items of 1286 documents
Percutaneous puncture of an aorto‐bifemoral bypass graft and successful closure with MANTA ® device in transfemoral TAVR
2021
Transfemoral aortic valve replacement (TAVR) has become a standard therapeutic option for patients with symptomatic severe aortic stenosis. Special anatomies can pose distinct challenges for vascular access and later closure of the access site, for example, in preoperated patients. Here, we elucidate a case of transfemoral TAVR with vascular access by direct puncture of an aorto-bifemoral bypass graft and illustrate the feasibility of vascular closure by an anchored collagen-plug vascular closure device (Teleflex MANTA® ).
Mechanical circulatory support. An expert opinion of the Association of Intensive Cardiac Care and the Association of Cardiovascular Interventions of…
2021
Mechanical circulatory support (MCS) methods are used in patients with both acute and chronic heart failure, who have exhausted other options for pharmacological or surgical treatments. The purpose of their use is to support, partially or completely, the failed ventricles and ensure adequate organ perfusion, which allows patients to restore full cardiovascular capacity, prolonging their life and effectively improving its quality. The three most popular devices include an intra-aortic balloon pump (IABP), percutaneous assist devices (including Impella, TandemHeart), and venoarterial extracorporeal membrane oxygenation (VA-ECMO). A multidisciplinary approach with the special participation of …
Interventional femoral “crossover” bypass for peripheral ischaemia under cardiocirculatory support with the Impella CP heart pump
2020
Failure mode and effects analysis of skin electronic brachytherapy using Esteya® unit
2016
Purpose: Esteya® (Nucletron, an Elekta company, Elekta AB, Stockholm, Sweden) is an electronic brachytherapy device used for skin cancer lesion treatment. In order to establish an adequate level of quality of treatment, a risk analysis of the Esteya treatment process has been done, following the methodology proposed by the TG-100 guidelines of the American Association of Physicists in Medicine (AAPM). Material and methods: A multidisciplinary team familiar with the treatment process was formed. This team developed a process map (PM) outlining the stages, through which a patient passed when subjected to the Esteya treatment. They identified potential failure modes (FM) and each individual FM…
Novel Application of Pulsed Radiofrequency Energy Device (PEAK Plasmablade) in Neurosurgical Reconstructive Surgery.
2018
Alternative methods of mechanical Cardiopulmonary Resuscitation
2000
Due to the relative ineffectiveness of standard resuscitation techniques, alternative methods have been explored for many years. The aim of new methods is to improve haemodynamics and increase survival rates. In spite of some encouraging haemodynamic results, all but one study failed to show an increase in long-term survival rates with an alternative method in a convincingly large group of patients (hospital discharge without neurological damage, and 1-year survival). In this study active compression-decompression resuscitation (ACD-CPR) increased long-term survival compared to standard-CPR. The results from certain individual studies, which showed a significant increase in short-term survi…
2018
The pre-supplementary motor area (pre-SMA) is engaged in speech comprehension under difficult circumstances such as poor acoustic signal quality or time-critical conditions. Previous studies found that left pre-SMA is activated when subjects listen to accelerated speech. Here, the functional role of pre-SMA was tested for accelerated speech comprehension by inducing a transient "virtual lesion" using continuous theta-burst stimulation (cTBS). Participants were tested (1) prior to (pre-baseline), (2) 10 min after (test condition for the cTBS effect), and (3) 60 min after stimulation (post-baseline) using a sentence repetition task (formant-synthesized at rates of 8, 10, 12, 14, and 16 syllab…
New applicator improves waterjet dissection quality
2010
Waterjet dissection is accomplished with Helix Hydro-Jet, but a new device with improved operative handling and potentially superior dissection qualities has been developed.Eighty-four fresh cadaveric pig brains were simultaneously cut with Helix Hydro-Jet and Erbejet 2. A commonly used applicator and a new applicator for the Helix Hydro-Jet were directly compared to the new Erbejet 2. Under standardised conditions, different pressure levels were applied to the brain surface without arachnoids. Technical features, cutting depth, tissue damage and differences of applicators were examined.Microscopic analysis of cutting depth revealed different dissection characteristics of both the devices. …
OneShot-M: A New Device for Close Laparoscopy Pneumoperitoneum
2018
Introduction. The induction of pneumoperitoneum is the first and most critical phase of laparoscopy, due to the significant risk of serious vascular and visceral complications. The closed technique for the creation of pneumoperitoneum could lead to several surgical complications. The present study aimed to overcome the complications associated with the insertion of Veress needle, improving its use, and facilitating the rapid creation of pneumoperitoneum. Methods. Thirty large white female pigs were enrolled in our study. A common plunger was modified in order to allow the passage of a 15-cm long Veress needle. This method was applied to 26 laparoscopic procedures (26 pigs) of several speci…
The use of a new kind of low profile retractor for arteriovenous fistula procedure simplifies and speeds up the intervention
2009
Purpose The aim of this study was to demonstrate the effectiveness of a new kind of disposable surgical retractor in arteriovenous fistula (AVF) procedures in order to achieve an easier, faster and safer surgical intervention. Methods Between January and June 2008, 22 AVF procedures were performed using the 3PAWS ReeTrakttrade; (Insightra Inc. - Irvine, Ca., USA) a self-retaining, low profile retractor. An equivalent patient sample, in which an AVF was performed using conventional retraction devices, was considered for comparison of the intra- and post-operative results. Results In all of the 22 AVF procedures performed, the ReeTrakt™ system has simplified the performance of the surgical te…