Search results for "device"

showing 10 items of 1286 documents

Percutaneous puncture of an aorto‐bifemoral bypass graft and successful closure with MANTA ® device in transfemoral TAVR

2021

Transfemoral aortic valve replacement (TAVR) has become a standard therapeutic option for patients with symptomatic severe aortic stenosis. Special anatomies can pose distinct challenges for vascular access and later closure of the access site, for example, in preoperated patients. Here, we elucidate a case of transfemoral TAVR with vascular access by direct puncture of an aorto-bifemoral bypass graft and illustrate the feasibility of vascular closure by an anchored collagen-plug vascular closure device (Teleflex MANTA® ).

medicine.medical_specialtyPercutaneousbusiness.industryVascular accessClosure (topology)030204 cardiovascular system & hematologymedicine.diseaseSurgery03 medical and health sciencesStenosis0302 clinical medicineAortic valve replacementDirect punctureAccess sitemedicineRadiology Nuclear Medicine and imagingVascular closure device030212 general & internal medicineCardiology and Cardiovascular MedicinebusinessEchocardiography
researchProduct

Mechanical circulatory support. An expert opinion of the Association of Intensive Cardiac Care and the Association of Cardiovascular Interventions of…

2021

Mechanical circulatory support (MCS) methods are used in patients with both acute and chronic heart failure, who have exhausted other options for pharmacological or surgical treatments. The purpose of their use is to support, partially or completely, the failed ventricles and ensure adequate organ perfusion, which allows patients to restore full cardiovascular capacity, prolonging their life and effectively improving its quality. The three most popular devices include an intra-aortic balloon pump (IABP), percutaneous assist devices (including Impella, TandemHeart), and venoarterial extracorporeal membrane oxygenation (VA-ECMO). A multidisciplinary approach with the special participation of …

medicine.medical_specialtyPercutaneousmedicine.medical_treatmentShock CardiogenicPsychological interventionventilation and pharmacotherapyPercutaneous Coronary InterventionExtracorporeal membrane oxygenationHumansMedicineIntensive care medicineExpert TestimonyImpellaMechanical ventilationIntra-Aortic Balloon Pumpingbusiness.industryCardiogenic shockmechanical circulatory support-type and extensionmedicine.diseasehemodynamic and echocardiographic monitoringHeart failureConventional PCIindications and complicationsmultidisciplinary approachHeart-Assist DevicesPolandCardiology and Cardiovascular MedicinebusinessKardiologia Polska
researchProduct

Interventional femoral “crossover” bypass for peripheral ischaemia under cardiocirculatory support with the Impella CP heart pump

2020

medicine.medical_specialtyPeripheral ischaemiabusiness.industryShock CardiogenicIschemiaHeartmedicine.diseaseIschemiaShock (circulatory)Internal medicineCardiologymedicineHumansHeart-Assist Devicesmedicine.symptomCardiology and Cardiovascular MedicinebusinessImpellaEuroIntervention
researchProduct

Failure mode and effects analysis of skin electronic brachytherapy using Esteya® unit

2016

Purpose: Esteya® (Nucletron, an Elekta company, Elekta AB, Stockholm, Sweden) is an electronic brachytherapy device used for skin cancer lesion treatment. In order to establish an adequate level of quality of treatment, a risk analysis of the Esteya treatment process has been done, following the methodology proposed by the TG-100 guidelines of the American Association of Physicists in Medicine (AAPM). Material and methods: A multidisciplinary team familiar with the treatment process was formed. This team developed a process map (PM) outlining the stages, through which a patient passed when subjected to the Esteya treatment. They identified potential failure modes (FM) and each individual FM…

medicine.medical_specialtyQuality managementFrequency of occurrenceelectronic brachytherapymedia_common.quotation_subjectmedicine.medical_treatmentBrachytherapylcsh:MedicineTG-10003 medical and health sciences0302 clinical medicineRisk analysis (business)MedicineRadiology Nuclear Medicine and imagingQuality (business)Medical physicsQAFMEAmedia_commonOriginal Paperskin cancerBrachytherapy devicebusiness.industry030503 health policy & serviceslcsh:RTreatment processEsteyaOncology030220 oncology & carcinogenesis0305 other medical sciencebusinessFailure mode and effects analysisJournal of Contemporary Brachytherapy
researchProduct

Novel Application of Pulsed Radiofrequency Energy Device (PEAK Plasmablade) in Neurosurgical Reconstructive Surgery.

2018

medicine.medical_specialtyReconstructive surgeryWound HealingSettore MED/27 - Neurochirurgiabusiness.industryPulsed radiofrequencyRadio WavesPlastic Surgery ProceduresEnergy deviceRadio WavePulsed Radiofrequency Treatment03 medical and health sciences0302 clinical medicinePulsed Radiofrequency Treatment030220 oncology & carcinogenesisMedicineHumansSurgeryReconstructive Surgical ProceduresNeurology (clinical)Radiologybusiness030217 neurology & neurosurgeryHumanWorld neurosurgery
researchProduct

Alternative methods of mechanical Cardiopulmonary Resuscitation

2000

Due to the relative ineffectiveness of standard resuscitation techniques, alternative methods have been explored for many years. The aim of new methods is to improve haemodynamics and increase survival rates. In spite of some encouraging haemodynamic results, all but one study failed to show an increase in long-term survival rates with an alternative method in a convincingly large group of patients (hospital discharge without neurological damage, and 1-year survival). In this study active compression-decompression resuscitation (ACD-CPR) increased long-term survival compared to standard-CPR. The results from certain individual studies, which showed a significant increase in short-term survi…

medicine.medical_specialtyResuscitationmedicine.medical_treatmentGravity SuitsEmergency NursingDogsNeurological DamageHospital dischargeAnimalsHumansMedicineCardiopulmonary resuscitationAsystoleIntensive care medicineSurvival rateAlternative methodsbusiness.industrymedicine.diseaseCardiopulmonary ResuscitationSurvival RateCoughEmergency MedicineHeart-Assist DevicesCardiology and Cardiovascular MedicinebusinessLarge groupResuscitation
researchProduct

2018

The pre-supplementary motor area (pre-SMA) is engaged in speech comprehension under difficult circumstances such as poor acoustic signal quality or time-critical conditions. Previous studies found that left pre-SMA is activated when subjects listen to accelerated speech. Here, the functional role of pre-SMA was tested for accelerated speech comprehension by inducing a transient "virtual lesion" using continuous theta-burst stimulation (cTBS). Participants were tested (1) prior to (pre-baseline), (2) 10 min after (test condition for the cTBS effect), and (3) 60 min after stimulation (post-baseline) using a sentence repetition task (formant-synthesized at rates of 8, 10, 12, 14, and 16 syllab…

medicine.medical_specialtySpeech perceptionRepetition (rhetorical device)Supplementary motor areaGeneral Neurosciencemedia_common.quotation_subject05 social sciencesCTBSContext (language use)Audiology050105 experimental psychologyTask (project management)03 medical and health sciences0302 clinical medicinemedicine.anatomical_structurePerceptionotorhinolaryngologic diseasesmedicine0501 psychology and cognitive sciencesPsychology030217 neurology & neurosurgerySentencemedia_commonFrontiers in Neuroscience
researchProduct

New applicator improves waterjet dissection quality

2010

Waterjet dissection is accomplished with Helix Hydro-Jet, but a new device with improved operative handling and potentially superior dissection qualities has been developed.Eighty-four fresh cadaveric pig brains were simultaneously cut with Helix Hydro-Jet and Erbejet 2. A commonly used applicator and a new applicator for the Helix Hydro-Jet were directly compared to the new Erbejet 2. Under standardised conditions, different pressure levels were applied to the brain surface without arachnoids. Technical features, cutting depth, tissue damage and differences of applicators were examined.Microscopic analysis of cutting depth revealed different dissection characteristics of both the devices. …

medicine.medical_specialtySwineHydrostatic pressureBrain surfaceDissection (medical)Neurosurgical ProceduresTissue damageHydrostatic PressuremedicineAnimalsNew devicebusiness.industryDissectionBrainEquipment DesignGeneral MedicineSurgical Instrumentsmedicine.diseaseSurgeryArachnoidsModels AnimalSurgeryNeurology (clinical)businessCadaveric spasmBiomedical engineeringBritish Journal of Neurosurgery
researchProduct

OneShot-M: A New Device for Close Laparoscopy Pneumoperitoneum

2018

Introduction. The induction of pneumoperitoneum is the first and most critical phase of laparoscopy, due to the significant risk of serious vascular and visceral complications. The closed technique for the creation of pneumoperitoneum could lead to several surgical complications. The present study aimed to overcome the complications associated with the insertion of Veress needle, improving its use, and facilitating the rapid creation of pneumoperitoneum. Methods. Thirty large white female pigs were enrolled in our study. A common plunger was modified in order to allow the passage of a 15-cm long Veress needle. This method was applied to 26 laparoscopic procedures (26 pigs) of several speci…

medicine.medical_specialtySwineSettore VET/09 - Clinica Chirurgica Veterinaria030230 surgeryCritical phase03 medical and health sciencesabdominal entry0302 clinical medicinePneumoperitoneumAnimalsMedicineNew deviceSignificant riskIntraoperative ComplicationsNeedlestick InjuriesLaparoscopyminimally invasive surgeryVeress needlemedicine.diagnostic_testbusiness.industryInsufflationoperating room technologymedicine.diseaseVeress needleinnovationSurgerybody regionsSettore MED/18 - Chirurgia GeneraleNeedles030220 oncology & carcinogenesisModels AnimalFemaleLaparoscopySurgerybusinessPneumoperitoneum ArtificialSurgical Innovation
researchProduct

The use of a new kind of low profile retractor for arteriovenous fistula procedure simplifies and speeds up the intervention

2009

Purpose The aim of this study was to demonstrate the effectiveness of a new kind of disposable surgical retractor in arteriovenous fistula (AVF) procedures in order to achieve an easier, faster and safer surgical intervention. Methods Between January and June 2008, 22 AVF procedures were performed using the 3PAWS ReeTrakttrade; (Insightra Inc. - Irvine, Ca., USA) a self-retaining, low profile retractor. An equivalent patient sample, in which an AVF was performed using conventional retraction devices, was considered for comparison of the intra- and post-operative results. Results In all of the 22 AVF procedures performed, the ReeTrakt™ system has simplified the performance of the surgical te…

medicine.medical_specialtyTime Factorsmedicine.medical_treatment030232 urology & nephrologyArteriovenous fistulaarterioveunous fistula retractors030204 cardiovascular system & hematology03 medical and health sciencesArteriovenous Shunt Surgical0302 clinical medicineOperating timeHumansMedicinePatient groupDisposable EquipmentReduction (orthopedic surgery)Brachiocephalic VeinsRetrospective StudiesSurgical teamSurgical instrumentationSurgical Fixation Devicebusiness.industryEquipment DesignSurgical Instrumentsmedicine.diseasearteriovenous fistulaReeTrakt systemSurgeryRetractorForearmSettore MED/18 - Chirurgia GeneraleTreatment OutcomeNephrologyRadial ArterySurgerybusiness
researchProduct