Impact of Pre-Analytical Time on the Recovery of Pathogens from Blood Cultures: Results from a Large Retrospective Survey.
2017
Background Prompt identification of bloodstream pathogens is essential for optimal management of patients. Significant changes in analytical methods have improved the turnaround time for laboratory diagnosis. Less attention has been paid to the time elapsing from blood collection to incubation and to its potential effect on recovery of pathogens. We evaluated the performance of blood cultures collected under typical hospital conditions in relation to the length of their pre-analytical time. Methods We carried out a large retrospective study including 50,955 blood cultures collected, over a 30-month period, from 7,035 adult septic patients. Cultures were accepted by the laboratory only durin…
Improved electroless platinum contacts on CdZnTe X- and γ-rays detectors
2020
AbstractPlatinum is a promising candidate for the realization of blocking electrical contacts on cadmium-zinc-telluride (CdZnTe or CZT) radiation detectors. However, the poor mechanical adhesion of this metal often shortens the lifetime of the final device. In this work, a simple and effective procedure to obtain robust platinum contacts by electroless deposition is presented. Microscopical analysis revealed the final thickness and composition of the contact layer and its adhesion to the bulk crystal. The blocking nature of the Pt-CdZnTe junction, essential to obtain low noise devices, was confirmed by current–voltage measurements. The planar Pt-CdZnTe-Pt detectors showed good room temperat…
Redox-Active Ferrocene grafted on H-Terminated Si(111): Electrochemical Characterization of the Charge Transport Mechanism and Dynamics
2019
AbstractElectroactive self-assembled monolayers (SAMs) bearing a ferrocene (Fc) redox couple were chemically assembled on H-terminated semiconducting degenerate-doped n-type Si(111) substrate. This allows to create a Si(111)|organic-spacer|Fc hybrid interface, where the ferrocene moiety is covalently immobilized on the silicon, via two alkyl molecular spacers of different length. Organic monolayer formation was probed by Laser Ablation-Inductively Coupled Plasma-Mass Spectrometry (LA-ICP-MS) and X-ray photoelectron spectroscopy (XPS) measurements, which were also used to estimate thickness and surface assembled monolayer (SAM) surface coverage. Atomic force microscopy (AFM) measurements all…
Matching the Directions of Electric Fields from Triboelectric and Ferroelectric Charges in Nanogenerator Devices for Boosted Performance
2020
Summary Embedding additional ferroelectric dipoles in contacting polymer layers is known to enhance the performance of triboelectricnanogenerator (TENG) devices. However, the influence of dipoles formed between the triboelectric surface charges on two contacting ferroelectric films has been ignored in all relevant studies. We demonstrate that proper attention to the alignment of the distinct dipoles present between two contacting surfaces and in composite polymer/BaTiO3 ferroelectric films can lead to up to four times higher energy and power density output compared with cases when dipole arrangement is mismatched. For example, TENG device based on PVAc/BaTiO3 shows energy density increase f…
Surface structure promoted high-yield growth and magnetotransport properties of Bi2Se3 nanoribbons
2019
AbstractIn the present work, a catalyst-free physical vapour deposition method is used to synthesize high yield of Bi2Se3 nanoribbons. By replacing standard glass or quartz substrates with aluminium covered with ultrathin porous anodized aluminium oxide (AAO), the number of synthesized nanoribbons per unit area can be increased by 20–100 times. The mechanisms of formation and yield of the nanoribbons synthesized on AAO substrates having different arrangement and size of pores are analysed and discussed. It is shown that the yield and average length of the nanoribbons can base tuned by adjustment of the synthesis parameters. Analysis of magnetotransport measurements for the individual Bi2Se3…
Can life be standardized? Current challenges in biological standardization
2021
The concept of standard strongly evokes machines, industries, electric or mechanical devices, vehicles, or furniture. Indeed, our technological civilization would not be possible – at least in the terms it is structured today – without universal, reliable components, whose acknowledged use results in competitive costs, robustness and interchangeability. For example, an Ikea screw can be used in a wide set of structurally dissimilar furniture and an app can be run on many different smartphones. The very concept of standardization is linked to the industrial revolution and mass production of goods through assembly lines. The question we will try to answer in the present paper is the extent to…
M-TRAP: Safety and performance of metastatic tumor cell trap device in advanced ovarian cancer patients
2021
Objective. Despite radical surgery and chemotherapy, most patients with ovarian cancer die due to disease progression. M-Trap is an implantable medical device designed to capture peritoneal disseminated tumor cells with the aim to focalize the disease. This trial analyzed the safety and performance of the device. Methods. This first-in-human prospective, multi-center, non-blinded, single-arm study enrolled 23 women with high-grade serous advanced ovarian cancer. After primary or interval debulking surgery, 3 M-Trap devices were placed in the peritoneum of the abdominal cavity. 18-months post-implantation or at disease progression, devices were initially removed by laparoscopy. The primary s…
Three-dimensional multiple-particle tracking with nanometric precision over tunable axial ranges
2017
The precise localization of nanometric objects in three dimensions is essential to identify functional diffusion mechanisms in complex systems at the cellular or molecular level. However, most optical methods can achieve high temporal resolution and high localization precision only in two dimensions or over a limited axial (z) range. Here we develop a novel wide-field detection system based on an electrically tunable lens that can track multiple individual nanoscale emitters in three dimensions over a tunable axial range with nanometric localization precision. The optical principle of the technique is based on the simultaneous acquisition of two images with an extended depth of field while …
Fast Inertia-Free Volumetric Light-Sheet Microscope
2017
Fast noninvasive three-dimensional (3D) imag-ing is crucial for quantitatively studying highly dynamic events ranging from flow cytometry to developmental biology. Light-sheet microscopy has emerged as the tool-of-choice for 3D characterization of rapidly evolving systems. However, to obtain a 3D image, either the sample or parts of the microscope are moved, limiting the acquisition speed. Here, we propose a novel inertia-free light-sheet-based scheme for volumetric imaging at high temporal resolution. Our approach comprises a novel combination of an acousto-optic scanner to produce tailored illumination and an acoustic-optofluidic lens, placed in the detection path to provide extended dept…
Comparative study of the production of soluble factors in human placenta-derived mesenchymal stromal/stem cells grown in adherent conditions or as ag…
2019
Abstract Different approaches have been studied in both preclinical and clinical settings to develop cell-based therapies and/or engineered cell-based therapies to better integrate grafts with the host. In these techniques, much attention is addressed to the use of adult stem cells such as mesenchymal stem cells (MSCs), but identifying and obtaining sufficient numbers of therapeutic cells, and the right route of administration, is often a challenge. In this study, we tested the feasibility of encapsulating human amnion-derived MSCs (hAMSCs) in a semipermeable and biocompatible fiber as a new approach for regenerative medicine. Our data showed that hAMSCs aggregated in the device constitutes…