The old and new tests for celiac disease: which is the best test combination to diagnose celiac disease in pediatric patients?

2011

BACKGROUND In the diagnosis of celiac disease (CD), serum assays for anti-endomysium (EMA) and anti-transglutaminase (anti-tTG) antibodies have excellent diagnostic accuracy. However, these assays are less sensitive in young pediatric patients. Recently, a new ELISA test using deamidated gliadin peptides (DGP) as antigen has proved to be very sensitive and specific even in pediatric patients. In addition, anti-actin IgA antibodies (AAA) is another test that can be used in CD patients because antibody concentrations correlate with the degree of villous atrophy. This study evaluated the clinical accuracy of anti-tTG, EMA, AGA, anti-DGP and AAA and the effectiveness of these in different combi…

Malemedicine.medical_specialtySettore MED/09 - Medicina InternaTissue transglutaminaseClinical BiochemistryFluorescent Antibody TechniqueDiagnostic accuracyEnzyme-Linked Immunosorbent AssayDiseaseGastroenterologySensitivity and SpecificityAntigenInternal medicinemedicineHumansceliac disease; diagnostic test; pediatric patientspediatric patientsbiologybusiness.industryClinical Laboratory TechniquesBiochemistry (medical)InfantGeneral MedicineReference StandardsEndomysiummedicine.anatomical_structurediagnostic testCase-Control StudiesChild PreschoolElisa testbiology.proteinFemaleAntibodyGliadinbusinessceliac disease
researchProduct

Diagnostic accuracy of computed tomographic colonography for the detection of advanced neoplasia in individuals at increased risk of colorectal cance…

2009

CONTEXT: Computed tomographic (CT) colonography has been recognized as an alternative for colorectal cancer (CRC) screening in average-risk individuals, but less information is available on its performance in individuals at increased risk of CRC. OBJECTIVE: To assess the accuracy of CT colonography in detecting advanced colorectal neoplasia in asymptomatic individuals at increased risk of CRC using unblinded colonoscopy as the reference standard. DESIGN, SETTING, AND PARTICIPANTS: This was a multicenter, cross-sectional study. Individuals at increased risk of CRC due to either family history of advanced neoplasia in first-degree relatives, personal history of colorectal adenomas, or positiv…

Maleoccult blood testColorectal cancerColonoscopycancer riskprediction and forecastingGastroenterologyRisk Factorscancer diagnosisPositive predicative valueadvanced cancerMedicineFamily historycomparative studycolorectal adenomafamily historyeducation.field_of_studymedicine.diagnostic_testarticleclinical trialGeneral MedicineColonoscopyMiddle Agedpriority journalrisk factorPredictive value of testsdiagnostic accuracyFemalediagnostic valueColorectal NeoplasmsColonography Computed TomographicradiographyComputed TomographicAdultmedicine.medical_specialtySettore MED/12 - GASTROENTEROLOGIAPopulationcolorectal cancerSensitivity and SpecificityPredictive Value of TestsInternal medicineadult; advanced cancer; aged; article; cancer classification; cancer diagnosis; cancer risk; clinical trial; colonoscopy; colorectal adenoma; colorectal cancer; computed tomographic colonography; controlled clinical trial; controlled study; cross-sectional study; diagnostic accuracy; diagnostic value; family history; female; human; major clinical study; male; multicenter study; occult blood test; predictive validity; priority journal; colorectal tumor; comparative study; middle aged; prediction and forecasting; radiography; risk factor; sensitivity and specificity; Adult; Aged; Colonography Computed Tomographic; Colonoscopy; Colorectal Neoplasms; Cross-Sectional Studies; Female; Humans; Male; Middle Aged; Predictive Value of Tests; Risk Factors; Sensitivity and Specificitycross-sectional studyHumanscontrolled studyhumaneducationAgedcontrolled clinical trialbusiness.industryFecal occult bloodSigmoidoscopyColonographymedicine.diseasecancer classificationcomputed tomographic colonographymajor clinical studypredictive validitymulticenter studyCross-Sectional StudiesCT colonography colorectal cancer screeningSettore MED/36 - Diagnostica Per Immagini E Radioterapiabusinesscolorectal tumorJAMA
researchProduct

Independent Validation of Sepsis Index for Sepsis Screening in the Emergency Department

2021

(1) Background: The early detection of sepsis is still challenging, and there is an urgent need for biomarkers that could identify patients at a high risk of developing it. We recently developed an index, namely the Sepsis Index (SI), based on the combination of two CBC parameters: monocyte distribution width (MDW) and mean monocyte volume (MMV). In this study, we sought to independently validate the performance of SI as a tool for the early detection of patients at a high risk of sepsis in the Emergency Department (ED). (2) Methods: We enrolled all consecutive patients attending the ED with a request of the CBC. MDW and MMV were measured on samples collected in K3-EDTA tubes on the UniCel …

Medicine (General)030213 general clinical medicinemedicine.medical_specialtyClinical BiochemistryEarly detectionDiagnostic accuracy030204 cardiovascular system & hematologyLikelihood ratios in diagnostic testingArticleMonocytesSepsis03 medical and health sciencesR5-9200302 clinical medicineMDWSepsisInternal medicinemedicinebusiness.industryCurve analysisMMVBiomarkerEmergency departmentmedicine.diseasePredictive valueScreeningBiomarker (medicine)businessCBCDiagnostics
researchProduct

Detection of RAS mutations in circulating tumor DNA: a new weapon in an old war against colorectal cancer. A systematic review of literature and meta…

2019

Background: Tissue evaluation for RAS (KRAS or NRAS) gene status in metastatic colorectal cancer (mCRC) patients represent the standard of care to establish the optimal therapeutic strategy. Unfortunately, tissue biopsy is hampered by several critical limitations due to its invasiveness, difficulty to access to disease site, patient’s compliance and, more recently, neoplastic tissue spatial and temporal heterogeneity. Methods: The authors performed a systematic literature review to identify available trials with paired matched tissue and ctDNA RAS gene status evaluation. The authors searched EMBASE, MEDLINE, Cochrane, www.ClinicalTrials.gov , and abstracts from international meetings. In to…

Neuroblastoma RAS viral oncogene homologOncologymedicine.medical_specialtyStandard of careColorectal cancerSettore MED/06 - Oncologia Medicamedicine.disease_causelcsh:RC254-282meta-analysi03 medical and health sciences0302 clinical medicineInternal medicinemedicineLiquid biopsy030304 developmental biologyTherapeutic strategycirculating tumor DNAcirculating tumor DNA; diagnostic accuracy; liquid biopsy; meta-analysis; metastatic colorectal cancer; RAS0303 health sciencesliquid biopsybusiness.industrymetastatic colorectal cancermedicine.diseaselcsh:Neoplasms. Tumors. Oncology. Including cancer and carcinogens3. Good healthmeta-analysisOncologyCirculating tumor DNA030220 oncology & carcinogenesisMeta-analysisdiagnostic accuracyKRASbusinessRAS
researchProduct

Metastatic site location may influence the diagnostic accuracy of plasma EGFR-mutation testing in NSCLC: A pooled analysis

2017

Oncologymedicine.medical_specialtyPooled analysisOncologySite locationEgfr mutationbusiness.industryInternal medicinemedicineDiagnostic accuracyHematologybusinessAnnals of Oncology
researchProduct

Comparison of diagnostic accuracy between periapical and panoramic radiographs and cone beam computed tomography in measuring the periapical area of …

2019

Background The aim of the study was compare the sensitivity and measurements obtained from teeth with apical lesions scheduled for periapical surgery using three different diagnostic methods: periapical radiography (Gendex Expert DC), panoramic radiography (Planmeca® Promax 3D Classic) and cone beam computed tomography (CBCT) (Planmeca® Promax 3D Classic). Material and methods This cross-sectional study involved 35 patients (45 teeth) scheduled for periapical surgery in which periapical radiographs, panoramic radiographs and CBCT scans had been obtained. The images were used to analyze the maximum vertical and horizontal dimension and the resulting areas of the periapical lesions based on t…

OrthodonticsCone beam computed tomographybusiness.industryRadiographyPeriapical radiographymedicine.medical_treatmentResearchDiagnostic accuracy030206 dentistry:CIENCIAS MÉDICAS [UNESCO]Operative Dentistry and EndodonticsPeriapical lesion03 medical and health sciences0302 clinical medicinestomatognathic system030220 oncology & carcinogenesisCoronal planeApicoectomyUNESCO::CIENCIAS MÉDICASMedicinebusinessGeneral DentistryPeriapical surgeryJournal of Clinical and Experimental Dentistry
researchProduct

Diagnostic yield of ink-jet prints from digital radiographs for the assessment of approximal carious lesions: ROC-analysis

2009

Abstract Aims To investigate the diagnostic quality of different quality, individually calibrated ink-jet printers for the very challenging dental radiographic task of approximal carious lesion detection. Materials and methods A test-pattern evaluating resolution, contrast and homogeneity of the ink-jet prints was developed. 50 standardized dental radiographs each showing two neighbouring teeth in natural contact were printed on glossy paper with calibrated, randomly selected ink-jet printers (Canon S520 and iP4500, Epson Stylus Photo R2400). Printing size equalled the viewing size on a 17″ cathode-ray-tube monitor daily quality-tested according to German regulations. The true caries status…

PaperOrthodonticsDental radiographymedicine.diagnostic_testbusiness.industryRadiographySignificant differenceReproducibility of ResultsDentistryDiagnostic accuracyRadiography Dental DigitalGeneral MedicineDental CariesCritical ratioROC CurveDiagnostic qualityHumansPrintingMedicineInkRadiology Nuclear Medicine and imagingCarious lesionComputer PeripheralsbusinessWorking environmentEuropean Journal of Radiology
researchProduct

Quality of individually calibrated customary printers for assessment of typical dental diagnoses on glossy paper prints: a multicenter pilot study.

2007

Objective The objective of this study was to compare dental radiographs printed on glossy paper from calibrated low-cost printers with monitor display. Study design Three typical intraoral radiographs were selected and a questionnaire was developed with questions assessing accuracy and subjective quality. A test pattern was designed for printer calibration. After calibration, radiographs were printed on glossy paper with 3 ink-jet and 2 thermo-sublimation printers. Sixteen raters evaluated the printed radiographs, 9 of them also on standardized viewing monitors. Subjective ratings were compared, and an ROC-analysis based on expert-consensus monitor readings was performed. Results Low inter-…

Papermedicine.medical_specialtyComputer sciencemedia_common.quotation_subjectDiagnostic accuracyPilot ProjectsmedicineHumansQuality (business)Medical diagnosisSubjective qualityComputer PeripheralsGeneral Dentistrymedia_commonObserver VariationDiagnosis OralRadiography Dental DigitalSurgeryOtorhinolaryngologyMulticenter studyROC CurveCalibrationOptometryPrintingSurgeryOral SurgeryOral surgery, oral medicine, oral pathology, oral radiology, and endodontics
researchProduct

Validity of needle core biopsy in the histological characterisation of mammary lesions

2006

Summary Over the last few years, there has been an enormous increase in the use of needle core biopsy (CB) for the histopathological characterisation of suspect lesions of the breast. The aim of this study was to verify the diagnostic reliability of CB by comparing the histological results obtained with the use of this technique with those obtained from the whole of the surgically resected specimen. We studied 198 out of 426 patients with clinically and/or radiologically suspect breast lesions. We found correspondence between the histological examination of the whole of the excised specimen and that of the CB in 94.9% of the cases of infiltrating carcinoma and in 71.4% of those involving du…

Pathologymedicine.medical_specialtyReproducibility of ResultBreast NeoplasmsSensitivity and SpecificityBreast cancerNeedle core biopsyRetrospective StudiemedicineCarcinomaHumansbreast carcinomahumanintermethod comparisonarticle; breast carcinoma; breast disease; carcinoma in situ; diagnostic accuracy; diagnostic value; histopathology; human; human tissue; intermethod comparison; intraductal carcinoma; major clinical study; needle biopsy; prediction; priority journal; reliability; sensitivity and specificity; validation process Biopsy Needle; Breast Neoplasms; Carcinoma Ductal Breast; Carcinoma Intraductal Noninfiltrating; Female; Humans; Reproducibility of Results; Retrospective Studies; Sensitivity and Specificity [EMTREE medical terms]Retrospective Studiesintraductal carcinomaHistological examinationreliabilitybusiness.industryBiopsy Needlevalidation process MeSH: Biopsy NeedleCarcinoma Ductal Breastbreast diseaseReproducibility of Resultscarcinoma in situneedle biopsypredictionGeneral Medicinemedicine.diseasemajor clinical studyPredictive valuehuman tissueCarcinoma Intraductal Noninfiltratingpriority journalhistopathologyEMTREE medical terms: articlediagnostic accuracyFemaleSurgerydiagnostic valueRadiologybusinessCore biopsyBreast NeoplasmThe Breast
researchProduct

Computer assisted diagnosis (CAD) in mammography. Comparison of diagnostic accuracy of a new algorithm (Cyclopus(R), Medicad) with two commercial sys…

2008

The study compares the diagnostic accuracy (correct identification of cancer) of a new computer-assisted diagnosis (CAD) system (Cyclopus) with two other commercial systems (R2 and CADx). Cyclopus was tested on a set of 120 mammograms on which the two compared commercial systems had been previously tested. The set consisted of mammograms reported as negative, preceding 31 interval cancers reviewed as screening error or minimal sign, and of 89 verified negative controls randomly selected from the same screening database. Cyclopus sensitivity was 74.1% (R2=54.8%; CADx=41.9%) and was higher for interval cancers reviewed as screening error (90.9%; R2=54.5%; CADx=81.8%) compared with those revie…

Settore ING-INF/05 - Sistemi Di Elaborazione Delle Informazionimedicine.medical_specialtymedicine.diagnostic_testbusiness.industryBreast carcinomaSettore FIS/01 - Fisica SperimentaleCADDiagnostic accuracyBreast NeoplasmsGeneral MedicineSensitivity and SpecificitySettore FIS/07 - Fisica Applicata(Beni Culturali Ambientali Biol.e Medicin)Predictive Value of TestsmedicineComputer-assisted diagnosiMammographyHumansRadiology Nuclear Medicine and imagingMedical physicsFemaleRadiologyDiagnosis Computer-AssistedbusinessAlgorithmsMammography
researchProduct