Search results for "digital radio"
showing 8 items of 18 documents
Diagnostic Validity of Digital Imaging Fiber-Optic Transillumination (DIFOTI) and Near-Infrared Light Transillumination (NILT) for Caries in Dentine.
2020
The objective of the study is to analyse the available evidence for the validity of the transillumination method in the diagnosis of interproximal caries. Bibliographic searches were carried out in three data bases (PubMed, Embase, Scopus) with the key words “Transillumination AND caries”. A total of 11 studies were selected for the qualitative analysis and meta-analysis. In the qualitative analysis, both in vivo and in vitro studies were included. The gold standards were tomography, digital radiography, and clinical visual diagnosis. The meta-analysis determined the sensitivity, specificity, and area below the ROC curve relative to the transillumination method in the diagnosis …
Evaluation of a digital radiography to estimate working length
1997
The working lengths obtained with different methods in single-rooted teeth were compared. An endodontic rule in millimeters and calipers was used as a direct method of measurement (on endodontic files). As indirect methods, measurements were taken from conventional x-rays with calipers and with a digital radiological measurement system. No statistically significant differences were obtained between the direct and indirect methods. Three vertical angulations were taken for the indirect methods (0 degree, 15 degrees, and 30 degrees). No significant differences were found between results for the two indirect methods versus the standard method except for the 30 degrees angulation, which resulte…
In vitro comparison of root-canal measurements with conventional and digital radiology.
2002
Aim The present study compared the efficacy of digital and conventional radiology for root-canal length measurement. Methodology Seventy extracted teeth with pre-served roots were used. Root-canal length measurements were completed with K-Flexofiles (numbers 08, 10 and 15) with conventional and digital radiography using two systems (radiovisiography and photostimulate storage phosphor). All films and sensors were exposed at projections of 0 degrees and 20 degrees to the mesial. The images obtained were evaluated with and without magnification, and analysed using the Cohen's kappa test. The accuracy of the three systems to determine the root-canal length were evaluated by measuring the dista…
Digitale Mehrschichttomographie
1989
A set of projection images is acquired during longitudinal tomography with an image intensifier TV system. Reconstruction of tomograms in each desired plane is achieved by shifting and summing up of the digitalized projection images. Digital multilayer and conventional film tomograms mainly of the respiratory tract and skeleton have been compared in 100 patients. Image quality is comparable with both methods. Disadvantage of digital tomography is lower spatial resolution (512 x 512 matrix size); advantages include lower radiation dose, shorter study time, and facilities of digital imaging.
Wireless ATM : handover issues
1998
Basic aspects of cellular systems and the ATM transmission technology are introduced. Wireless ATM is presented as a combination of radio ATM and mobile ATM. Radio ATM is a wireless extension of an ATM connection while mobile ATM contains the necessary extensions to ATM to support mobility. Because the current ATM technology does not support mobility, handover becomes one of the most important research issues for wireless ATM. Wireless ATM handover requirements are thus analysed. A handover solution relying on two inter-related handover protocols is presented and evaluated. Future research is needed to compare this solution with options presented by earlier research and possibly combine the…
Clinical and radiographic diagnosis of approximal and occlusal dental caries in a low risk population
2007
Objective: Determine the agreement between visual detection, conventional radiology and digital radiology methods in the diagnosis of interproximal and occlusal caries in the posterior teeth of a group of patients with low caries prevalence. Materials and Methods: Visual, conventional radiographic and digital radiographic (Digora®, Soredex, Sweden) caries diagnosis was performed in a group of patients (n=30) of both sexes with ages ranging from 15 to 65 years (x = 34 years). Agreement was estimated by the linear weighted kappa index. Results: Kappa = 0.17 was obtained between the visual examination and the conventional radiographic examination and Kappa = 0.16 between the visual examination…
Die Röntgendigitalanlage als Instrument zur kinematischen Untersuchung der Schulter — Eine Untersuchung zur Strahlenbelastung - Digital Radiography a…
1991
The radiation exposure during biomechanical investigation of the shoulder joint done with a digital radiography system (Polytron 1000 VR - Siemens) was measured experimentally. Total radiation dose and surface dose were determined by phantom measurements. The radiation exposure per image is about 1/6 to 1/7 of that of a conventional study. The digital radiography system used is thus suitable for kinesiologic studies of large joints in healthy volunteers.
The migration of femoral components after total hip replacement surgery: accuracy and precision of software-aided measurements.
2003
To assess the accuracy and precision of a software-aided system to measure migration of femoral components after total hip replacement (THR) on digitised radiographs.Subsidence and varus-valgus tilt of THR stems within the femur were measured on digitised anteroposterior pelvic radiographs. The measuring software (UMA, GEMED, Germany) relies on bony landmarks and comparability parameters of two consecutive radiographs. Its accuracy and precision were calculated by comparing it with the gold standard in migration measurements, radiostereometric analysis (RSA). Radiographs and corresponding RSA measurements were performed in 60 patients (38-69 years) following cementless THR surgery.The UMA s…