Search results for "doppler echocardiography"
showing 10 items of 39 documents
Echocardiographic reference ranges for normal cardiac Doppler data: results from the NORRE Study
2015
International audience; AIMS: Reference values for Doppler parameters according to age and gender are recommended for the assessment of heart physiology, specifically for left ventricular (LV) diastolic function. In this study, we report normal reference ranges for Doppler parameters obtained in a large group of healthy volunteers. Echocardiographic data were acquired using state-of-the-art cardiac ultrasound equipment following Doppler acquisition and measurement protocols approved by the European Association of Cardiovascular Imaging. METHODS AND RESULTS: A total of 449 (mean age: 45.8 ± 13.7 years) healthy volunteers (198 men and 251 women) were enrolled at the collaborating institutions…
Echo-Doppler left ventricular filling abnormalities in patients with rheumatoid arthritis without clinically evident cardiovascular disease
1996
Our investigation aimed at verifying diastolic abnormalities in rheumatoid patients, without clinically evident cardiovascular disease and other confounding complaints, by using pulsed Doppler examination of transmitral blood flow. We selected 40 patients fulfilling revised American Rheumatism Association (ARA) criteria for the diagnosis of rheumatoid arthritis having no symptoms of cardiac disease or clinical findings of other extracardiac diseases. We also studied 40 rheumatoid-matched healthy volunteers as a control group. An echocardiographic examination was carried out on each subject. Left ventricular structural and functional measurements were obtained. Interventricular, septal thick…
Extreme Pulsus Alternans with P Wave Alternans in a Child
2002
Pulsus alternans was observed in a child with left ventricular dysfunction secondary to systemic hypertension. The Echo-Doppler of supravalvular aorta and a simultaneous electrocardiographic trace (ECG) clearly demonstrated the mechanism of an apparent abrupt halving of pulse frequency compared with the ECG, similar to an electromechanical dissociation 2: 1. Besides the extreme pulsus alternans, a P wave and a PP cycle length change were also observed. Both mechanical and electrical alternans disappeared with afterload reduction by nitroprusside treatment.
Normal Reference Ranges for Echocardiography: Rationale, study design, and methodology (NORRE Study)
2013
International audience; BACKGROUND: Availability of normative reference values for cardiac chamber dimensions, volumes, mass, and function is a prerequisite for the accurate application of echocardiography for both clinical and research purposes. However, due to the lack of consistency in current echocardiographic 'reference values', their use for clinical decision-making remains questionable. AIMS: The aim of the 'Normal Reference Ranges for Echocardiography Study (NORRE Study)' is to obtain a set of 'normal values' for cardiac chamber geometry and function in a large cohort of healthy Caucasian individuals aged over a wide range of ages (25-75 years) using both conventional and advanced e…
Prognostic Implications of Tissue Doppler Imaging-Derived E/Ea Ratio in Acute Heart Failure Patients
2014
Background Tissue Doppler–derived transmitral to mitral annular early diastolic velocity ratio (E/Ea), as a noninvasive estimation of left ventricular (LV) filling pressures, is a strong prognosticator in various cardiac scenarios including chronic heart failure; nevertheless, its utility for risk stratification in the whole spectrum of acute heart failure (AHF) patients remains elusive. Thus, the aim of this study was to determine the association between E/Ea ratio and 1-year mortality in nonselected patients with AHF. Methods The study included 417 consecutive patients admitted for AHF. Twenty-two patients were excluded due to nonaccurate Ea measurements, leaving the final sample to be 39…
Changes in estimating echocardiography pulmonary capillary wedge pressure after hypersaline plus furosemide versus furosemide alone in decompensated …
2011
BACKGROUND: The aim of the study was to verify the effects of hypertonic saline solution (HSS) plus a high furosemide dose and light restriction of sodium intake compared with a high-dose infusion of furosemide alone on pulmonary capillary wedge pressure (PCWP), as determined by Doppler echocardiography and tissue Doppler imaging in patients suffering from decompensated heart failure. METHODS AND RESULTS: Consecutive patients in New York Heart Association functional class IV, unresponsive to oral high doses of furosemide up to 250-500 mg/d and/or combinations of diuretics, with ejection fraction <40%, serum creatinine <2 mg/dL, blood urea nitrogen ≤60 mg/dL, reduced urinary volume (<500 mL/…
Valve prosthesis-patient mismatch: hemodynamic, echocardiographic and clinical consequences
2011
OBJECTIVES: The purpose is to evaluate in vivo at rest and under stress conditions hemodynamic performance of the small size St. Jude Medical Regent (SJMR) prosthetic valve in patients with a body surface area (BSA) of 1.8 ± 0.11 m(2) and to define the role of valve prosthesis- patient mismatch on left ventricular mass regression following aortic valve replacement. METHODS: We evaluated 25 cases (12 males and 13 females, mean age 65.2 ± 8 years) of aortic valve replacement (17 mm SJMR in three cases and 19 mm SJMR in 22 cases). All the patients underwent at rest Doppler echocardiography before and after surgery and both basal and dobutamine stress echocardiography (DSE) at follow-up. The me…
Muscle fiber-type distribution predicts weight gain and unfavorable left ventricular geometry: a 19 year follow-up study
2006
Abstract Background Skeletal muscle consists of type-I (slow-twitch) and type-II (fast-twitch) fibers, with proportions highly variable between individuals and mostly determined by genetic factors. Cross-sectional studies have associated low percentage of type-I fibers (type-I%) with many cardiovascular risk factors. Methods We investigated whether baseline type-I% predicts left ventricular (LV) structure and function at 19-year follow-up, and if so, which are the strongest mediating factors. At baseline in 1984 muscle fiber-type distribution (by actomyosin ATPase staining) was studied in 63 healthy men (aged 32–58 years). The follow-up in 2003 included echocardiography, measurement of obes…
Dobutamine stress Doppler echocardiography: reproducibility and physiologic left ventricular filling patterns
1997
Qualitatively, dobutamine stress echocardiography has become an established procedure. Quantitative results are in great demand but this is still difficult due to limited endo- and epicardial border definition. Transmitral Doppler variables are strictly quantitative and less subjective. Furthermore, ischemic alterations precede systolic ones (ischemic cascade). There are preliminary reports of the utility of dobutamine stress Doppler echocardiography, but proof of reproducibility and left ventricular filling patterns are still lacking. Fourteen healthy volunteers (10 men, 4 women, median age 25.9 years, range 21-32 years) were investigated according to the usual dobutamine stress echocardio…
Evidence of impaired left ventricular systolic function by Doppler myocardial imaging in patients with systemic amyloidosis and no evidence of cardia…
2007
We examined the potential role of Doppler myocardial imaging for early detection of systolic dysfunction in patients with systemic amyloidosis (AL) but without evidence of cardiac involvement by standard echocardiography. We identified 42 patients without 2-dimensional echocardiographic or Doppler evidence of cardiac involvement. These patients had normal ventricular wall thickness and normal velocity of the medial mitral annulus. Myocardial images were obtained in these patients and in 32 age- and gender-matched healthy controls. Peak longitudinal systolic tissue velocity (sTVI), systolic strain rate (sSR), and systolic strain (sS) were determined for 16 left ventricular segments. Radial a…