Search results for "doppler effect"
showing 10 items of 148 documents
First light observations of the solar wind in the outer corona with the Metis coronagraph
2021
In this work, we present an investigation of the wind in the solar corona that has been initiated by observations of the resonantly scattered ultraviolet emission of the coronal plasma obtained with UVCS-SOHO, designed to measure the wind outflow speed by applying Doppler dimming diagnostics. Metis on Solar Orbiter complements the UVCS spectroscopic observations that were performed during solar activity cycle 23 by simultaneously imaging the polarized visible light and the H I Lyman-α corona in order to obtain high spatial and temporal resolution maps of the outward velocity of the continuously expanding solar atmosphere. The Metis observations, taken on May 15, 2020, provide the first H I …
Measuring the electron temperatures of coronal mass ejections with future space-based multi-channel coronagraphs: a numerical test
2018
Context. The determination from coronagraphic observations of physical parameters of the plasma embedded in coronal mass ejections (CMEs) is of crucial importance for our understanding of the origin and evolution of these phenomena. Aims. The aim of this work is to perform the first ever numerical simulations of a CME as it will be observed by future two-channel (visible light VL and UV Ly-α) coronagraphs, such as the Metis instrument on-board ESA-Solar Orbiter mission, or any other future coronagraphs with the same spectral band-passes. These simulations are then used to test and optimize the plasma diagnostic techniques to be applied to future observations of CMEs. Methods. The CME diagno…
Line parameters and shapes of high clusters: R-branch of the nu3 band of CH4 in He mixtures
2002
International audience; The IR absorption spectra of CH4 in pure gas and in mixture with helium were studied in the region of nu3 band at higher J line clusters R(17)-R(22). The frequencies and intensities of rotation-vibration lines were estimated from the experimental spectra at Doppler shape conditions. The line frequencies and intensities were calculated and used for the attribution of overlapped lines in clusters. The calculated line intensities are close to the experimental values. The calculated frequency structure of the higher J manifolds are somewhat wider than the observed one. The shapes of helium-broadened line clusters were compared with those calculated accounting for line mi…
Performance analysis of Alamouti-coded OFDM systems over spatio-temporally correlated underwater acoustic channels
2017
In this paper, we analyze the performance of Alamouti-coded orthogonal frequency division multiplexing (OFDM) systems over time-varying underwater acoustic (UWA) channels. A realistic UWA channel model has been considered, which can be correlated in either time or space or simultaneously in both domains. An exact analytical expression for the bit error probability (BEP) is necessary to analyze accurately the performance of Alamouti-coded OFDM systems over the spatio-temporally correlated UWA channel model. Hence, by using this UWA channel model, an expression has been derived for the BEP of Alamouti-coded OFDM systems assuming that the receiver knows perfectly the channel state information.…
A 3D Non-Stationary Cluster Channel Model for Human Activity Recognition
2019
Author's accepted manuscript. © 2019 IEEE. Personal use of this material is permitted. Permission from IEEE must be obtained for all other uses, in any current or future media, including reprinting/republishing this material for advertising or promotional purposes, creating new collective works, for resale or redistribution to servers or lists, or reuse of any copyrighted component of this work in other works. This paper proposes a three-dimensional (3D) non- stationary fixed-to-fixed indoor channel simulator model for human activity recognition. The channel model enables the formulation of temporal variations of the received signal caused by a moving human. The moving human is modelled by …
A non-stationary relay-based 3D MIMO channel model with time-variant path gains for human activity recognition in indoor environments
2021
AbstractExtensive research showed that the physiological response of human tissue to exposure to low-frequency electromagnetic fields is the induction of an electric current in the body segments. As a result, each segment of the human body behaves as a relay, which retransmits the radio-frequency (RF) signal. To investigate the impact of this phenomenon on the Doppler characteristics of the received RF signal, we introduce a new three-dimensional (3D) non-stationary channel model to describe the propagation phenomenon taking place in an indoor environment. Here, the indoor space is equipped with a multiple-input multiple-output (MIMO) system. A single person is moving in the indoor space an…
Coupling hydrodynamics and radiation calculations for star-jet interactions in active galactic nuclei
2016
Context. Stars and their winds can contribute to the non-thermal emission in extragalactic jets. Because of the complexity of jet-star interactions, the properties of the resulting emission are closely linked to those of the emitting flows. Aims. We simulate the interaction between a stellar wind and a relativistic extragalactic jet and use the hydrodynamic results to compute the non-thermal emission under different conditions. Methods. We performed relativistic axisymmetric hydrodynamical simulations of a relativistic jet interacting with a supersonic, non-relativistic stellar wind. We computed the corresponding streamlines out of the simulation results and calculated the injection, evolut…
Ultrasonographic Detection of Vascularity of Focal Breast Lesions: Microvascular Imaging Versus Conventional Color and Power Doppler Imaging.
2021
To compare microvascular flow imaging (MVFI) to conventional Color-Doppler (CDI) and Power-Doppler (PDI) imaging in the detection of vascularity of Focal Breast Lesions (FBLs). A total of 180 solid FBLs (size: 3.5–45.2 mm) detected in 180 women (age: 21–87 years) were evaluated by means of CDI, PDI, and MVFI. Two blinded reviewers categorized lesion vascularity in absent or present, and vascularity pattern as (a) internal; (b) vessels in rim; (c) combined. The presence of a “penetrating vessel” was assessed separately. Differences in vascularization patterns (chi2 test) and intra- and inter-observer agreement (Fleiss method) were calculated. ROC analysis was performed to assess performance…
Image-Guided Transcranial Doppler Ultrasound for Monitoring Posthemorrhagic Vasospasms of Infratentorial Arteries: A Feasibility Study
2019
Background A considerable number of patients with subarachnoid hemorrhage (SAH) develop vasospasms of the infratentorial arteries. Transcranial Doppler sonography (TCD) is used to screen for vasospasm. In this study, we used a technical modification that combines TCD with an image guidance device that the operator can use to navigate to the ultrasonic window and to predefined intracranial vascular targets. Our aim was to analyze the feasibility, spatial precision, and spatial reproducibility of serial image-guided TCD of infratentorial and—for comparison—supratentorial arteries in the clinical setting of monitoring for vasospasm after SAH. Methods The study included 10 SAH patients, who eac…
Analysis of Internal Jugular Vein Insufficiency—A Comparison of Two Ultrasound Methods
2006
Abstract Jugular venous valve insufficiency is a contributing factor to different pathologic conditions. For assessment of insufficiency, two ultrasound techniques have been developed, that are based on very different methodology (direct Doppler assessment versus air contrast ultrasound venography [ACUV]). This study was conducted to compare these two methods to improve comparability of existing studies and diagnostic accuracy in future studies. The function of 40 valves was determined in 20 individuals during a Valsalva maneuver. For direct Doppler assessment, valvular competence was assessed on basis of Doppler recordings, following recently established criteria. Valvular insufficiency in…