Search results for "doppler"

showing 10 items of 637 documents

Congenital mitral regurgitation caused by a perforation in the anterior leaflet: Perioperative evaluation by color-coded Doppler echocardiography

1990

Color-coded two-dimensional (2D) echocardiography confirmed the presence of severe congenital mitral regurgitation in an 8-month-old infant. Intraoperative inspection revealed an isolated perforation in the anterior leaflet.

Congenital mitral regurgitationmedicine.medical_specialtyPerforation (oil well)Doppler echocardiographyInternal medicinemedicineHumanscardiovascular diseasesMitral regurgitationAnterior leafletmedicine.diagnostic_testbusiness.industryInfantMitral Valve InsufficiencyPerioperativeVascular surgeryEchocardiography DopplerCardiac surgerySurgeryPediatrics Perinatology and Child Healthcardiovascular systemCardiologyMitral ValveFemaleCardiology and Cardiovascular MedicinebusinessPediatric Cardiology
researchProduct

Intraluminal Doppler-Sonography: Analysis and “in Vitro Test” of a New Device

1992

In treating patients with coronary heart disease it’ s necessary first to determine what influence the stenose has on the coronary blood flow. This is a prerequisite for any invasive treatment method. Coronary angiography explosures are only partially useful in attaining a functional evaluation of the haemodynamic stenoses.

Coronary angiographymedicine.medical_specialtyIn vitro testbusiness.industryHemodynamicsTreatment methodBlood flowCoronary heart diseaseDoppler sonographyInternal medicineCardiologymedicineNew devicebusiness
researchProduct

MOJAVE: Monitoring of Jets in Active Galactic Nuclei with VLBA Experiments. VI. Kinematics Analysis of a Complete Sample of Blazar Jets

2009

We discuss the jet kinematics of a complete flux-density-limited sample of 135 radio-loud active galactic nuclei (AGN) resulting from a 13 year program to investigate the structure and evolution of parsec-scale jet phenomena. Our analysis is based on new 2 cm Very Long Baseline Array (VLBA) images obtained between 2002 and 2007, but includes our previously published observations made at the same wavelength, and is supplemented by VLBA archive data. In all, we have used 2424 images spanning the years 1994-2007 to study and determine the motions of 526 separate jet features in 127 jets. The data quality and temporal coverage (a median of 15 epochs per source) of this complete AGN jet sample r…

Cosmology and Nongalactic Astrophysics (astro-ph.CO)Active galactic nucleusLorentz transformationAstrophysics::High Energy Astrophysical PhenomenaPopulationFOS: Physical sciencesAstrophysicsKinematicsAstrophysics::Cosmology and Extragalactic Astrophysics01 natural sciencessymbols.namesake0103 physical scienceseducationBlazar010303 astronomy & astrophysicsVery Long Baseline ArrayPhysicseducation.field_of_study010308 nuclear & particles physicsAstronomy and AstrophysicsWavelength13. Climate actionSpace and Planetary SciencesymbolsDoppler effectAstrophysics - Cosmology and Nongalactic Astrophysics
researchProduct

Incomplete self-similarity and flow velocity in gravel bed channels

2000

Velocity measurements, previously carried out using both a miniature current flowmeter and an acoustic Doppler velocimeter, are used to verify the applicability of the incomplete self-similarity theory to deduce the velocity profile in a gravel bed channel. Then, for the velocity profiles having the maximum value below the free surface and for the S-shaped profiles, the power velocity distribution is corrected using a new divergence function. For each value of the depth sediment ratio the nondimensional friction factor parameter is calculated by integration of the measured velocity distributions in the different verticals of the cross section. Finally, a semilogarithmic flow resistance equa…

Cross section (physics)Flow velocitySelf-similarityFree surfaceflow velocity gravel bed self-similarityGeotechnical engineeringShear velocityMechanicsAcoustic Doppler velocimetryGeologyFlow measurementWater Science and TechnologyPower (physics)
researchProduct

Impact of implant thread design on insertion torque and osseointegration:a preclinical model

2022

Successful osseointegration of endosteal dental implants has been attributed to implant design, including the macro-, micro- and nano- geometric properties. Based on current literature pertaining to implant design, the resultant cellular and bone healing response is unknown when the thread thickness of the implants is increased, resulting in an increased contact area in implants designed with healing chambers. The aim of this study was to evaluate the effect of two implant designs with different thread profiles on the osseointegration parameters and implant stability at 3- and 6-weeks in vivo using a well-established preclinical dog model. A total of 48 type V Ti alloy implants were divided…

Dental Implantsdoppler ultrasound imagingSurface PropertiesultrasoundDental Implantation Endosseousinfectionultrasound imagingDogsOtorhinolaryngologyTorqueDental Prosthesis DesignOsseointegrationAnimalsSurgeryGeneral DentistryUNESCO:CIENCIAS MÉDICAS
researchProduct

Remote photoplethysmography for assessment of oral mucosa

2019

The present study is devoted to the assessment of oral mucosa perfusion using remote photoplethysmography (rPPG) technique. The alterations of mucosal perfusion were evoked by regional infiltration anesthesia containing adrenaline. Simple rPPG setup comprising white LED light source, video camera and narrowband optical filter (CWL=540nm), are able to detect subtle microcirculation changes in gingiva. Results demonstrate substantial decrease of rPPG waveform amplitude and subsequently perfusion index in affected gingiva region, following administration of anesthetics. The present study emphasizes clinical advantages of remote photoplethysmography and perfusion index mapping as a simple and c…

Dental anesthesiaLight sourcemedicine.anatomical_structureInfiltration anesthesiabusiness.industryPhotoplethysmogrammedicineOral mucosaLaser Doppler velocimetrybusinessPerfusionMicrocirculationBiomedical engineeringClinical and Preclinical Optical Diagnostics II
researchProduct

Non invasive tools for the diagnosis of liver cirrhosis

2014

Liver cirrhosis (LC), the end stage of many forms of chronic hepatitis of different etiologies is a diffuse process characterized by fibrosis and the conversion of normal liver architecture into structurally abnormal nodules surrounded by annular fibrosis. This chronic progressive clinical condition, leads to liver cell failure and portal hypertension, which can favour the onset of hepatocellular carcinoma. Defining the phase of the natural history is crucial for therapeutic choice and prognosis. Liver biopsy is currently considered the best available standard of reference but it has some limits, so alternative tools have been developed to substitute liver biopsy when assessing liver fibros…

Diagnostic ImagingLiver Cirrhosismedicine.medical_specialtyCirrhosisSettore MED/09 - Medicina InternaBiopsyContrast MediaReviewSeverity of Illness IndexGastroenterologySerum markersPredictive Value of TestsFibrosisInternal medicineUltrasoundBiopsymedicineHumansLiver fibrosis; Liver biopsy; Ultrasound; Elastography; Serum markersmedicine.diagnostic_testbusiness.industryLiver cellGastroenterologyReproducibility of ResultsLiver fibrosiUltrasonography DopplerGeneral MedicineLiver biopsyPrognosismedicine.diseaseLiverLiver biopsyHepatocellular carcinomaElasticity Imaging TechniquesPortal hypertensionRadiologyElastographyElastographybusinessBiomarkers
researchProduct

Methods to investigate coronary microvascular function in clinical practice.

2012

A growing amount of data is increasingly showing the relevance of coronary microvascular dysfunction (CMVD) in several clinical contexts. This article reviews techniques and clinical investigations of the main noninvasive and invasive methods proposed to study coronary microcirculation and to identify CMVD in the presence of normal coronary arteries, also trying to provide indications for their application in clinical practice.

Diagnostic Imagingmedicine.medical_specialtymyocardial contrast echocardiographyCoronary microcirculationCoronary Artery DiseaseCoronary microvascular functionDiagnostic toolsintracoronary Doppler ultrasoundMicrocirculationcoronary microcirculationtransthoracic Doppler echocardiographyCoronary artery diseaseCoronary circulationcardiovascular magnetic resonanceInternal medicineCoronary CirculationmedicineDIAGNOSTIC TOOLSHumansNormal coronary arteriesbusiness.industryMicrocirculationGeneral Medicinemedicine.diseaseSettore MED/11 - Malattie Dell'Apparato Cardiovascolarediagnostic investigationClinical PracticeMyocardial contrast echocardiographymedicine.anatomical_structurePETcardiovascular magnetic resonance; coronary microcirculation; diagnostic investigation; intracoronary Doppler ultrasound; myocardial contrast echocardiography; PET; transthoracic Doppler echocardiography; Coronary Artery Disease; Coronary Circulation; Diagnostic Imaging; Humans; Microcirculation; Cardiology and Cardiovascular MedicineSettore MED/11 - MALATTIE DELL'APPARATO CARDIOVASCOLARECardiologymicrovascular functionHEARTCORONARYbusinessCardiology and Cardiovascular Medicine
researchProduct

Long-lived dynamic heterogeneity in a relaxor ferroelectric

1998

The polydispersive dielectric response of the relaxor ferroelectric lead magnesium niobate was investigated using nonresonant spectral hole-burning experiments. Using large alternating electric fields, specific parts of the relaxation-time distribution could be addressed selectively. This provides evidence for the dynamic heterogeneity of the dipolar reorientation process. The refilling of single as well as of double holes was much slower than the time scale set by the pump frequencies. Upon refilling, the holes exhibited no signs of spectral broadening. The present findings suggest a speedup of polarization response associated with a domain-wall depinning that is induced by the hole-burnin…

DipoleCondensed Matter::Materials ScienceNuclear magnetic resonanceMaterials scienceCondensed matter physicsElectric fieldLead magnesium niobateGeneral Physics and AstronomyPolarization (waves)Dielectric response530Doppler broadeningRelaxor ferroelectric
researchProduct

Editor's Choice – Follow-up of Patients After Revascularisation for Peripheral Arterial Diseases: A Consensus Document From the European Society of C…

2019

International audience; Peripheral arterial diseases comprise different clinical presentations, from cerebrovascular disease down to lower extremity artery disease, from subclinical to disabling symptoms and events. According to clinical presentation, the patient's general condition, anatomical location and extension of lesions, revascularisation may be needed in addition to best medical treatment. The 2017 European Society of Cardiology guidelines in collaboration with the European Society for Vascular Surgery have addressed the indications for revascularisation. While most cases are amenable to either endovascular or surgical revascularisation, maintaining long-term patency is often chall…

Disease030204 cardiovascular system & hematology030230 surgeryPostoperative Complications0302 clinical medicineRestenosisRecurrenceSecondary Preventionfollow-upRandomized Controlled Trials as TopicUltrasonography Doppler Duplexmedicine.diagnostic_test3. Good healthEuropeSystematic reviewPractice Guidelines as TopicIN-STENT RESTENOSISCardiologyCardiology and Cardiovascular MedicineVascular Surgical ProceduresReoperationmedicine.medical_specialtyConsensusRevascularisationINFRAINGUINAL VEIN BYPASSMEDLINEPhysical examinationSTENOSIS03 medical and health sciencesrestenosisperipheral arterial diseaseInternal medicinemedicineHumansANGIOPLASTYVELOCITY CRITERIAbusiness.industryMagnetic resonance imagingNATURAL-HISTORYPerioperativeVascular surgery3126 Surgery anesthesiology intensive care radiologymedicine.diseaseDUPLEX ULTRASOUND SURVEILLANCEENDOVASCULAR TREATMENTRISK-FACTORSSurgery[SDV.SPEE]Life Sciences [q-bio]/Santé publique et épidémiologieCAROTID-ARTERYbusiness
researchProduct