Diffusion coefficient of PVA Fricke gel dosimeters

2015

Fricke gel dosimeters based on various matrix has been studied for a long time as 3D dosimetric system for radiotherapy. Selfoxidation and loss of spatial resolution due to diffusion have been the main issues that have impaired the affirmation of this technique so far. As part of an Italian nation-wide research program, we were interested in develop new gel formulations that are simple, reproducible and non toxic. We studied the one dimensional diffusion coefficient of Fe3+ ions inside Fricke gel dosimeters based on a matrix of PVA cross-linked with a di-aldehyde. With a spectrophotometer equipped with a moving tray we were able to collect absorbance measurements at different positions of t…

DIFFUSIONSSettore ING-IND/20 - Misure E Strumentazione NucleariPVASettore FIS/01 - Fisica SperimentaleGEL DOSIMETERSOPTICAL DENSITYSettore FIS/07 - Fisica Applicata(Beni Culturali Ambientali Biol.e Medicin)
researchProduct

Phenol compounds for Electron Spin Resonance dosimetry in gamma and neutron field

2016

The use of neutrons for cancer treatments has stimulated the research for beam characterization in order to optimize the therapy procedures in Neutron Capture Therapy (Altieri, 2008). Several research laboratories have shown an increasing interest aimed at extending the applicability of Electron Spin Resonance (ESR) dosimetry to radiotherapy with different types of radiation beams. In particular, ESR spectrometry provides absorbed dose measurements through the detection of the stable free radicals produced by ionizing radiations. The ESR dosimetric method has many advantages such as simple and rapid dose evaluation, the readout procedure is non-destructive, linear response of many organic a…

ESR EPR Solid state dosimeters neutronsSettore FIS/01 - Fisica SperimentaleSettore FIS/07 - Fisica Applicata(Beni Culturali Ambientali Biol.e Medicin)
researchProduct

PVA-GTA Fricke gel dosimeters exposed to clinical photons beams: Nuclear Magnetic Resonance Relaxometry and Imaging

2016

Fricke Gel (FXGs) dosimetric system is based on the radiation induced oxidation of ferrous to ferric ions. The application of Fricke gels for ionizing radiation dosimetry is continuously increasing worldwide due to their many favorable properties. However, one of their shortcomings is that ferrous and ferric ions diffuse in the gel matrix. To maintain the spatial integrity of the dose distribution, Fricke gels must be undergoing measurement within a few hours of their irradiation, so that ferric ions remain close to their point of production. Thus, the spatial integrity of the dose distribution in the Fricke gel is maintained (Schreiner, 2015). The gel matrix also contributes to the oxidati…

Gel Dosimeters NMR MRI PVA GTA 3D DoseSettore ING-IND/20 - Misure E Strumentazione NucleariSettore FIS/01 - Fisica SperimentaleSettore FIS/07 - Fisica Applicata(Beni Culturali Ambientali Biol.e Medicin)
researchProduct

Influence of the simultaneous calibration of multiple ring dosimeters on the individual absorbed dose

2021

Abstract Ring dosimeters for personal dosimetry are calibrated in accredited laboratories following ISO 4037-3 guidelines. The simultaneous irradiation of multiple dosimeters would save time, but has to be carefully studied, since the scattering conditions could change and influence the absorbed dose in nearby dosimeters. Monte Carlo simulations using PENELOPE-2014 were performed to explore the need to increase the uncertainty of H p 0 .07 in the simultaneous irradiation of three and five DXT-RAD 707H-2 (Thermo Scientific) ring dosimeters with beam qualities: N-30, N-80 and N-300. Results show that the absorbed dose in each dosimeter is compatible with each of the others and with the refere…

Materials scienceDosimeterRadiation Dosimetersbusiness.industryMonte Carlo methodPublic Health Environmental and Occupational HealthCoverage probabilityGeneral Medicine030218 nuclear medicine & medical imaging03 medical and health sciences0302 clinical medicineOptics030220 oncology & carcinogenesisAbsorbed doseCalibrationCalibrationDosimetryComputer SimulationIrradiationRadiometryCalibration ISO 4037 Monte Carlo Personal dosimetry Ring dosimetersbusinessMonte Carlo MethodWaste Management and DisposalBeam (structure)Journal of Radiological Protection
researchProduct

Calibration of a thermoluminescent dosimeter worn over lead aprons in fluoroscopy guided procedures

2018

Fluoroscopy guided interventional procedures provide remarkable benefits to patients. However, medical staff working near the scattered radiation field may be exposed to high cumulative equivalent doses, thus requiring shielding devices such as lead aprons and thyroid collars. In this situation, it remains an acceptable practice to derive equivalent doses to the eye lenses or other unprotected soft tissues with a dosimeter placed above these protective devices. Nevertheless, the radiation backscattered by the lead shield differs from that generated during dosimeter calibration with a water phantom. In this study, a passive personal thermoluminescent dosimeter (TLD) was modelled by means of …

Materials scienceeye lens doseTLDImaging phantom030218 nuclear medicine & medical imaging03 medical and health sciences0302 clinical medicineOpticsProtective Clothingfashionbackscatter correction factorCalibrationmedicineDosimetryFluoroscopylead apronWaste Management and DisposalDosimetermedicine.diagnostic_testRadiation Dosimetersbusiness.industryEquivalent dosePublic Health Environmental and Occupational HealthEquipment DesignGeneral MedicinefluoroscopyLeadFluoroscopy030220 oncology & carcinogenesisfashion.garmentCalibrationLead apronThermoluminescent DosimetryThermoluminescent dosimeterbusinessJournal of Radiological Protection
researchProduct

Neutron dosimetry by means of electron spin resonance (ESR) tecnique

2012

Along with the Neutron Capture Therapy (NCT) development and with the use of thermal neutrons for radiotherapeutic purposes, many efforts have been devoted to the beam characterization in order to optimize the therapy procedures. Reliable dosimetric measurements should be able to determine the various components (neutronic and photonic) of the mixed beam usually employed for therapy. We have studied the effect of the additive such as gadolinium and 10B-boric acid on the neutron sensitivity of alanine ESR dosimeters exposed to a gamma and mixed (n, gamma) field mainly composed by thermal neutrons. We have chosen both this additive nuclei because of their very high capture cross section to th…

Neutron dosimetryalanine ESR dosimetersSettore FIS/07 - Fisica Applicata(Beni Culturali Ambientali Biol.e Medicin)
researchProduct

Sensitivity of alanine dosimeters with gadolinium exposed to 6 MV photons at clinical doses.

2011

In this study we analyzed the ESR signal of alanine dosimeters with gadolinium exposed to 6 MV linear accelerator photons. We observed that the addition of gadolinium brings about an improvement in the sensitivity to photons because of its high atomic number. The experimental data indicated that the addition of gadolinium increases the sensitivity of the alanine to 6 MV photons. This enhancement was better observed at high gadolinium concentrations for which the tissue equivalence is heavily reduced. However, information about the irradiation setup and of the radiation beam features allows one to correct for this difference. Monte Carlo simulations were carried out to obtain information on …

PhotonESR dosimetryGadoliniumMonte Carlo methodAccelerationBiophysicschemistry.chemical_elementGadoliniumLinear particle acceleratorRadiology Nuclear Medicine and imagingIrradiationRadiometryMonte Carlo simulationAlaninePhotonsRadiationDosimeterAlanineChemistryX-RaysRadiochemistryElectron Spin Resonance SpectroscopyDose-Response Relationship RadiationSettore FIS/07 - Fisica Applicata(Beni Culturali Ambientali Biol.e Medicin)Alanine dosimeters gadoliniumLinear ModelsSensitivity (electronics)Monte Carlo MethodRadiation research
researchProduct

Characterisation of two new radiochromic gel dosimeters TruView™ and ClearView™ in combination with the vista™ optical CT scanner: A feasibility study

2018

This study aims at characterising the properties of TruView™ and ClearView™ two new gel dosimeters (Modus Medical Devices Inc.) and at studying the feasibility of relative dosimetry using these dosimeters and the Vista™ Optical CT scanner to accurately evaluate dose.In this work, we investigated key dosimetric aspects (dose response, energy and dose rate dependence) and stability of these radiochromic gels initiated in preliminary works (Huet et al., 2017; Colnot et al., 2017) using spectrophotometric measurements. Moreover, by mean of optical CT scanning (Vista™), their performances to measure relative depth dose (PDD) and cross profiles were analysed.TruView™ and ClearView™ present a line…

ScannerTomography Scanners X-Ray ComputedMaterials scienceBiophysicsGeneral Physics and AstronomyElectrons[SDV.CAN]Life Sciences [q-bio]/Cancer[PHYS.NEXP]Physics [physics]/Nuclear Experiment [nucl-ex]030218 nuclear medicine & medical imaging03 medical and health sciences0302 clinical medicineOptical ctRelative depthDosimetryRadiology Nuclear Medicine and imagingPhoton beamRadiometryComputingMilieux_MISCELLANEOUSPhotonsDosimeterPhantoms ImagingRadiation DosimetersStray lightOptical ImagingUncertaintyGeneral MedicineSpectrophotometry030220 oncology & carcinogenesisCalibrationFeasibility StudiesTomography X-Ray ComputedDose rateBiomedical engineering
researchProduct

Phenol compounds as new materials for Electron Paramagnetic Resonance dosimetry in clinical photon and electron beams,

2016

In the last decades several research laboratories have shown an increasing interest aimed at extending the applicability of Electron Paramagnetic Resonance (EPR) dosimetry to radiotherapy with different types of radiation beams. EPR is a spectroscopic method for investigating the structure and dynamics of such paramagnetic species. Free radicals are known to be produced when a compound is irradiated with ionizing radiations. The concentration of radiation-induced free radicals is proportional to the energy released inside in the medium and this allows for dosimetric measurements through EPR technique. The use of alanine as a dosimetric material gave the possibility to apply EPR spectroscopy…

Settore FIS/01 - Fisica SperimentaleESR EPR Solid State Dosimeters Clinical Beams New MaterialsSettore FIS/07 - Fisica Applicata(Beni Culturali Ambientali Biol.e Medicin)
researchProduct

Correction factors for ionization chamber measurements with the ‘Valencia’ and ‘large field Valencia’ brachytherapy applicators

2018

Treatment of small skin lesions using HDR brachytherapy applicators is a widely used technique. The shielded applicators currently available in clinical practice are based on a tungsten-alloy cup that collimates the source-emitted radiation into a small region, hence protecting nearby tissues. The goal of this manuscript is to evaluate the correction factors required for dose measurements with a plane-parallel ionization chamber typically used in clinical brachytherapy for the 'Valencia' and 'large field Valencia' shielded applicators. Monte Carlo simulations have been performed using the PENELOPE-2014 system to determine the absorbed dose deposited in a water phantom and in the chamber act…

Skin Neoplasmsmedicine.medical_treatmentBrachytherapyPhysics::Medical PhysicsMonte Carlo methodBrachytherapyDose profileRadiationImaging phantom030218 nuclear medicine & medical imaging03 medical and health sciences0302 clinical medicineOpticsmedicineRadiology Nuclear Medicine and imagingRadiometryValenciaPhysicsRadiological and Ultrasound TechnologybiologyPhantoms ImagingRadiation Dosimetersbusiness.industryRadiotherapy Dosagebiology.organism_classification030220 oncology & carcinogenesisAbsorbed doseIonization chamberbusinessMonte Carlo MethodPhysics in Medicine & Biology
researchProduct