Search results for "double"
showing 10 items of 2879 documents
Closed-loop bandwidth impact on MVSA for rotor broken bar diagnosis in IRFOC double squirrel cage induction motor drives
2013
This paper investigates the detectability of rotor broken bars in indirect rotor flux oriented control (IRFOC) for variable speed double cage induction motor drives, using vibration signature analysis techniques. The Impact of the closed loop control system cannot be neglected when the detection of rotor asymmetries in the machine is based on the signature analysis of electrical or mechanical variables. Therefore, the investigation of rotor fault components for different bandwidths of closed-loop regulators is necessary to evaluate its relevance in the above listed variables. This paper investigates the impact of the control system on relevance of the fault components computed from axial an…
Description and commissioning of NEXT-MM prototype: first results from operation in a Xenon-Trimethylamine gas mixture
2014
[EN] A technical description of NEXT-MM and its commissioning and first performance is reported. Having an active volume of ∼35 cm drift × 28 cm diameter, it constitutes the largest Micromegas-read TPC operated in Xenon ever constructed, made by a sectorial arrangement of the 4 largest single wafers manufactured with the Microbulk technique to date. It is equipped with a suitably pixelized readout and with a sufficiently large sensitive volume (∼23 l) so as to contain long (∼20 cm) electron tracks. First results obtained at 1 bar for Xenon and Trymethylamine (Xe-(2%)TMA) mixture are presented. The TPC can accurately reconstruct extended background tracks. An encouraging fu…
Ileo-ileal invagination--a cause of recurrent mid-gastrointestinal bleeding: diagnostic and endoscopic therapy by means of push-and-pull enteroscopy.
2008
The types of lesions that cause bleeding in the small bowel are similar to those found in other areas in the gastrointestinal tract, such as vascular malformations, ulcers and inflammatory lesions, neoplasms and other less common lesions like Meckel's diverticulum. This report describes three patients with suspected mid-gastrointestinal bleeding with no significant past medical history. Before presenting to our unit the diagnostic work-up such as oesophagogastroduodenoscopy, colonoscopy and radiological small bowel imaging such as conventional enteroclysis or magnet resonance imaging enteroclysis had been performed without detecting any bleeding source. Capsule endoscopy suspected an angiod…
Endoscopic interventions in the small bowel using double balloon enteroscopy: feasibility and limitations.
2007
Double-balloon enteroscopy (DBE) is a new endoscopic tool that not only allows diagnostic workup of small bowel diseases, but also makes it possible to carry out therapeutic interventions. However, for a variety of reasons, endoscopic therapy appears to be more difficult to carry out deep in the small bowel than in the upper or lower gastrointestinal tract.The purpose of this study was to evaluate the acute technical success and acute complication rate of DBE.Between June 2003 and July 2006, 353 patients (152 women, 201 men; mean age 60.3 +/- 17.1 yr) with suspected or known small bowel disease underwent 635 consecutive DBE procedures. The majority of the patients were suffering from midgas…
Double-balloon endoscopy for retrograde cholangiography in patients with choledochojejunostomy and Roux-en-Y reconstruction.
2009
BACKGROUND Choledochojejunal anastomoses with Roux-en-Y reconstruction excludes the biliary tract from conventional endoscopic retrograde cholangiography (ERC) with standard endoscopes due to the length of the interposed small bowel segment. Double-balloon enteroscopy (DBE) facilitates deep insertion into the small bowel and may be used to perform ERC in these patients. In the present case series we report our experience with diagnostic and therapeutic double-balloon ERC in patients with choledochojejunostomy to a long Roux-en-Y loop previously unavailable for standard length endoscopes. PATIENTS AND METHODS Between December 2004 and May 2008 15 patients (mean age: 60.2 years) with choledoc…
ag) Push-and-pull enteroscopy in the small bowel using the double-balloon technique: results of a prospective European multicenter study.
2005
BACKGROUND AND STUDY AIMS The aim of this study was to evaluate the feasibility, safety, and clinical impact of push-and-pull enteroscopy (PPE) in patients with suspected or documented small-bowel diseases, in a prospective multicenter trial in three European medical centers. PATIENTS AND METHODS A total of 100 patients (mean age 56 +/- 16 years; range 13 - 90) were included at the three institutions between July and November 2004. The leading symptoms were: acute recurrent or chronic gastrointestinal bleeding (n = 64), polyposis syndrome (n = 8), chronic abdominal pain (n = 7), chronic diarrhea (n = 7), and others (n = 14). RESULTS No major PPE-associated complications such as perforation,…
Double-balloon enteroscopy-facilitated cyanoacrylate-injection endotherapy of small-bowel varices: an international experience from 2 European tertia…
2019
Background and Aims Small-bowel varices (SBVs) are an uncommon consequence of portal hypertension. Radiologic intervention is usually considered for first-line management. When radiologic intervention is not possible, management options become very limited. The aim of this study was to evaluate the usefulness of double-balloon enteroscopy (DBE)-facilitated cyanoacrylate-injection endotherapy of SBVs. Methods This was a retrospective review of DBE-facilitated cyanoacrylate-injection endotherapy of SBVs (December 2015 to October 2016). Results Ten DBEs were performed in 6 patients (4 women; median age, 68.5 years). No radiologic or surgical options were deemed feasible. Thirteen nests of SBVs…
Push-and-Pull Enteroscopy using the Double-Balloon Technique: Method of Assessing Depth of Insertion and Training of the Enteroscopy Technique using …
2005
Background and study aims This study was conducted to test a method of measuring the depth of insertion into the small bowel during push-and-pull enteroscopy using the Erlangen Endo-Trainer. Furthermore, the Erlangen Endo-Trainer model for training in the new method of push-and-pull enteroscopy using the double-balloon technique was also evaluated. Materials and methods Specially prepared packages of porcine upper visceral organs were used, including the esophagus, stomach, duodenum, and small bowel, implanted into the Erlangen Endo-Trainer. In the first step of this study, all of the modifications needed to obtain a model useful for training in the new enteroscopy technique were tested, in…
Current status of double balloon enteroscopy with focus on the Wiesbaden results.
2006
Long-term outcome after argon plasma coagulation of small-bowel lesions using double-balloon enteroscopy in patients with mid-gastrointestinal bleedi…
2011
BACKGROUND AND STUDY AIMS Vascular malformations are the most common sources of bleeding in the small bowel. They can be treated with argon plasma coagulation (APC) during double-balloon enteroscopy (DBE). This study aimed to evaluate the long-term follow-up of the effectiveness of APC for small-bowel bleeding by means of a single-center retrospective study. PATIENTS AND METHODS Between June 2003 and December 2005, APC treatment for small-bowel lesions was carried out during DBE in 63 patients with known or suspected mid-gastrointestinal bleeding. Fifty patients were included in the analysis. Main outcome measurements were comparison of hemoglobin values and blood transfusion requirements b…