Search results for "dynamics."

showing 10 items of 9637 documents

NMR and μ+SR detection of unconventional spin dynamics in Er(trensal) and Dy(trensal) molecular magnets

2019

muon spin relaxation magnetization dynamics Lanthanides
researchProduct

Walking and Running Require Greater Effort from the Ankle than the Knee Extensor Muscles.

2016

The knee and ankle extensors as human primary antigravity muscle groups are of utmost importance in a wide range of locomotor activities. Yet, we know surprisingly little about how these muscle groups work, and specifically, how close to their maximal capacities they function across different modes and intensity of locomotion. Therefore, to advance our understanding of locomotor constraints, we determined and compared relative operating efforts of the knee and ankle extensors during walking, running, and sprinting.Using an inverse dynamics biomechanical analysis, the muscle forces of the knee and ankle extensors during walking (1.6 m·s), running (4.1 m·s), and sprinting (9.3 m·s) were quant…

musculoskeletal diseasesAdultMalemedicine.medical_specialtyPhysical Therapy Sports Therapy and RehabilitationWalkingLower limbankle extensorsRunning03 medical and health sciences0302 clinical medicineMedicineHumansOrthopedics and Sports MedicineKneeta315Muscle SkeletalHuman locomotionknee extensorsLocomotor activitiesMuscle forceKnee extensorsbusiness.industryWork (physics)Skeletal muscle030229 sport sciencesBiomechanical Phenomenamedicine.anatomical_structuresprintinginverse dynamics biomechanical analysismuscle forcesPhysical therapyAnkleAnklebusiness030217 neurology & neurosurgeryLocomotionMuscle ContractionMedicine and science in sports and exercise
researchProduct

Load Distribution in the Lumbar Spine During Modeled Compression Depends on Lordosis.

2021

Excessive or incorrect loading of lumbar spinal structures is commonly assumed as one of the factors to accelerate degenerative processes, which may lead to lower back pain. Accordingly, the mechanics of the spine under medical conditions, such as scoliosis or spondylolisthesis, is well-investigated. Treatments via both conventional therapy and surgical methods alike aim at restoring a “healthy” (or at least pain-free) load distribution. Yet, surprisingly little is known about the inter-subject variability of load bearings within a “healthy” lumbar spine. Hence, we utilized computer tomography data from 28 trauma-room patients, whose lumbar spines showed no visible sign of degeneration, to …

musculoskeletal diseasesHistologyLordosis0206 medical engineeringBiomedical EngineeringBioengineering02 engineering and technologyScoliosisbiomechanicsFacet joint03 medical and health sciences0302 clinical medicineLumbarCobb anglemedicineOriginal ResearchOrthodonticsbusiness.industryBioengineering and Biotechnologylumbar lordosisCompression (physics)Sacrummedicine.disease020601 biomedical engineeringSpondylolisthesisVertebramedicine.anatomical_structureMBS modelcurvaturemusculo skeletal modelforward dynamicsbusiness030217 neurology & neurosurgeryTP248.13-248.65BiotechnologyFrontiers in bioengineering and biotechnology
researchProduct

Comparison between the directly measured achilles tendon force and the tendon force calculated from the ankle joint moment during vertical jumps.

1988

Summary The purpose of this study was to compare the relationship between the achilles tendon force and the tendon force estimated from the ankle joint moment (EATF) during vertical jump. A healthy male subject performed the following jumps on the force platform: (a) maximal vertical jump from a squat position without counter-movement; (b) maximal vertical jump from an erect standing position with a preliminary counter-movement; (c) repetitive submaximal hopping on the spot with preferred frequency. The achilles tendon force was measured directly with an implanted tendon transducer in all jumping conditions. In addition the joint moment obtained from the film and ground reaction force was u…

musculoskeletal diseasesPhysicsAchilles tendonBiophysicsMechanicsAnatomymusculoskeletal systemmedicine.disease_causeTendonInverse dynamicsVertical jumpJumpingmedicine.anatomical_structuremedicineOrthopedics and Sports MedicineForce platformAnkleGround reaction forceClinical biomechanics (Bristol, Avon)
researchProduct

Ritz Solution for Transient Analysis of Variable-Stiffness Shell Structures

2020

The dynamic response of thin-walled structures is driven by mass and stiffness distribution. As such, variable-stiffness (VS) composites offer opportunities to tune structural dynamic responses. To this extent, efficient analysis tools become increasingly important for structural analysis and design purposes. In this work, an efficient and versatile Ritz method for free vibrations and linear transient analysis of VS doubly curved shell structures is presented. VS shell structures are modeled as an assembly of shell-like domains. The shell kinematics is based on the first-order shear deformation theory, and no further assumption is made on the shallowness or on the thinness of the structure.…

musculoskeletal diseasesanimal structuresMaterials scienceDistribution (number theory)Shell (structure)Aerospace Engineeringmacromolecular substances02 engineering and technologyVariable angle tow composites Composite shells Ritz method01 natural sciencesSpherical shellData preparation010305 fluids & plasmasComputer Science::RoboticsPhysics::Fluid Dynamics0203 mechanical engineering0103 physical sciencesmedicineComposite material020301 aerospace & aeronauticsVariable stiffnesstechnology industry and agricultureStiffnessequipment and suppliesTransient analysisFinite element methodmedicine.symptomAIAA Journal
researchProduct

Patient-specific computational evaluation of stiffness distribution in ascending thoracic aortic aneurysm

2021

Quantifying local aortic stiffness properties in vivo is acknowledged as essential to assess the severity of an ascending thoracic aortic aneurysm (ATAA). Recently, the LESI (local extensional stiffness identification) methodology has been established to quantify non-invasively local stiffness properties of ATAAs using electrocardiographic-gated computed tomography (ECG-gated CT) scans. The aim of the current study was to determine the most sensitive markers of local ATAA stiffness estimation with the hypothesis that direct measures of local ATAA stiffness could better detect the high-risk patients. A cohort of 30 patients (12 BAV and 18 TAV) referred for aortic size evaluation by ECG-gated…

musculoskeletal diseasesmedicine.medical_specialtyanimal structuresBicuspid aortic valveExtensional stiffness0206 medical engineeringBiomedical EngineeringBiophysicsHemodynamicsmacromolecular substances02 engineering and technologyPositive correlationThoracic aortic aneurysm03 medical and health sciencesVascular Stiffness0302 clinical medicineBicuspid aortic valveInternal medicinemedicineHumansOrthopedics and Sports MedicineAortic Pulse PressureAortaComputingMilieux_MISCELLANEOUSShear stressAortic Aneurysm Thoracicbusiness.industryRehabilitationHemodynamics[SPI.MECA.BIOM]Engineering Sciences [physics]/Mechanics [physics.med-ph]/Biomechanics [physics.med-ph]StiffnessPatient specificAscending thoracic aortic aneurysmmedicine.diseaseNoninvasive inverse method020601 biomedical engineeringAortic AneurysmAortic ValveCardiologyAortic stiffnessmedicine.symptombusiness030217 neurology & neurosurgeryJournal of Biomechanics
researchProduct

NEO1 and NEO-EXT studies: Long-term safety of repeat avalglucosidase alfa dosing for 4.5 years in late-onset Pompe disease patients

2019

Safety, tolerability, pharmacokinetics, pharmacodynamics, and exploratory efficacy of repeat avalglucosidase alfa dosing (5, 10, or 20 mg/kg qow) for 6 months were evaluated in NEO1 (NCT01898364) in late-onset Pompe disease patients either treatment-naive (Naive) or having received alglucosidase alfa for ≥9 months (Switch). In NEO-EXT (NCT02032524), an ongoing NEO1 extension, long-term safety and pharmacokinetics of repeat avalglucosidase alfa dosing will be monitored over 6 years. Interim safety results after 4.5 years of NEO-EXT are reported here. Mean ages at NEO1 enrollment were: Naive: 44.8 (SD:20.3, range:20-78) years and Switch: 46.7 (SD:14.1, range:21-68) years. Of the 24 NEO1 parti…

myalgiamedicine.medical_specialtyNauseabusiness.industryEndocrinology Diabetes and MetabolismBiochemistryRashEndocrinologyTolerabilityInternal medicinePharmacodynamicsGeneticsmedicineDosingmedicine.symptomAdverse effectbusinessMolecular BiologyAlglucosidase alfamedicine.drugMolecular Genetics and Metabolism
researchProduct

Multiphoton Absorption of Myoglobin Nitric-Oxide complex: Relaxation by D-NEMD of a Stationary State

2012

ABSTRACT: The photodissociation and geminate recombination of nitric oxide in myoglobin, under continuous illumination, is modeled computationally. The relaxation of the photon energy into the protein matrix is also considered in a single simulation scheme that mimics a complete experimental setup. The dynamic approach to non-equilibrium molecular dynamics is used, starting from a steady state, to compute its relaxation to equilibrium. Simulations are conducted for the native form of sperm whale myoglobin and for two other mutants, V68W and L29F, illustrating a fair diversity of spatial and temporal geminate recombination processes. Energy flow to the heme and immediate protein environment …

myoglobin molecular dynamics simulations non equilibriumThermal fluctuationsMolecular Dynamics SimulationNitric OxideArticleAbsorptionchemistry.chemical_compoundMolecular dynamicsComputational chemistryMaterials ChemistryPhysical and Theoretical ChemistryHemePhotonsSteady stateChemistryMyoglobinPhotodissociationTemperatureSettore FIS/07 - Fisica Applicata(Beni Culturali Ambientali Biol.e Medicin)Recombinant ProteinsSurfaces Coatings and FilmsProtein Structure TertiaryMyoglobinChemical physicsMutationRelaxation (physics)Stationary stateProtein Binding
researchProduct

Computational Modeling of Geminate Recombination and Energy Relaxation of Nitric Oxide in Myoglobin under Constant Illumination,

2011

myoglobinphotolysis molecular dynamics non equilibrium
researchProduct

Computational studies of biomolecular screening and interactions

2015

negative image-based screeningseulontamolecular dockingliganditlääkeaineetvirtual screeninglaskennallinen kemiabiomolekyylitmolecular dynamicscomputational drug discoverylääkesuunnittelukemialliset sidoksetlääkekemiatietokannatproteiinitvirtuaaliseulontabinding free energy
researchProduct