Search results for "eccentric"
showing 10 items of 182 documents
Tunable liquid lens equipped virtual reality adapter for scientific, medical, and therapeutic goals
2018
We adapted virtual reality appliances to use them in scientific medical diagnostics and therapeutic aims by incorporated as part of appliance ocular system two electrically tunable Optotune liquid lenses, controllable by computer USB ports within 20D range. In present time we used the appliance to investigate the mono- and/or binocularly illusory perception dominances (Shapiro and al;2008), nonlinearities caused by controversial Gestalt recognition of motion. Back layer of stimuli elements contained internal motion sources - clockwise spinning disk on neutral background. Disk consisted of centrosymmetric radial rays which luminance was sinus mode modulated along the disc circumference. Spin…
Red-green vs. blue-yellow spatio-temporal contrast sensitivity across the visual field
2011
We measured contrast sensitivity (CS) to sinusoidal spatio-temporal patterns isolating the red-green and blue-yellow mechanisms, at 21 locations in the visual field (including the fovea). These measurements complete the available data for the red-green mechanism at fovea and for both mechanisms outside fovea with non-stationary patterns. Chromatic detection surfaces are low-pass at fovea and CS decreases with eccentricity at a rate that depends on the spatial and temporal frequencies. Our results confirm that, in general, sensitivities decrease with eccentricity at different rates for stationary red-green and blue-yellow patterns at each point of the spatio-temporal domain and that the chro…
Modelling Demagnetized Permanent Magnet Synchronous Generators using Permeance Network Model with Variable Flux Sources
2019
The partial demagnetization in a four-pole 1.5 kW surface mounted permanent-magnet synchronous-generator was modeled by permeance network model (PNM). The results were compared to a 2-D time-stepping finite element analysis (FEA). Both models where simulated in scenarios where one of the magnets where 20 % and 100 % demagntized and when none of the magnets where demagnetised. The results showed that the proposed PNM with variable magnetic flux sources matched the results of the FEA. The proposed method only need to invers the permeance matrix once before the time simulation, while the traditinal PNM need to invers it in every time step. This make the proposed model less computationally heav…
Force-, power-, and elasticity-velocity relationships in walking, running, and jumping
1980
Ground reaction forces and mechanical power were investigated when the subjects walked normally, while they were racing or running at four speeds, and when they performed the running long jump take-off. In addition, the apparent spring constants of the support leg in eccentric and concentric phases were investigated at the four running speeds, during the running long jump take-off, and in the triple jump. Six club level track and field athletes, four national level long jumpers, and six national level triple jumpers took part in the study. Cinematographic technique and a mathematical model of hopping (Alexander and Vernon 1975) were employed in the analysis. Force and power values were foun…
Mechanical power and segmental contribution to force impulses in long jump take-off
1979
Changes in total mechanical work, its partitioning into different energy states, mechanical power, force-time characteristics, force impulses of body segments and mass center's pathway characteristics during long jump take-off were investigated on four national and six ordinary level athletes. Both cinematographic and force-platform techniques were used. The data showed that the national level jumpers had higher run-up and higher take-off (release) velocities in horizontal and vertical directions. In addition, they were able to utilize efficiently the elastic energy stored in the leg extensor muscles at take-off impact. This was seen in high support leg eccentric and concentric forces, whic…
Preferential Type II Muscle Fiber Damage From Plyometric Exercise
2012
Context: Plyometric training has been successfully used in different sporting contexts. Studies that investigated the effect of plyometric training on muscle morphology are limited, and results are controversial with regard to which muscle fiber type is mainly affected. Objective: To analyze the skeletal muscle structural and ultrastructural change induced by an acute bout of plyometric exercise to determine which type of muscle fibers is predominantly damaged. Design: Descriptive laboratory study. Setting: Research laboratory. Patients or Other Participants: Eight healthy, untrained individuals (age = 22 ± 1 years, height = 179.2 ± 6.4 cm, weight = 78.9 ± 5.9 kg). Intervention(s): Partici…
Analisi teorico-sperimentale del comportamento flessionale di colonne in calcestruzzo fibrorinforzato
2009
Stato, rivoluzione e violenza simbolica. Una lettura à la Bourdieu dell’insorgenza cilena
2023
The essay is part of a book that aims to rediscover and enhance Pierre Bourdieu's contribution to the legal philosophy. Clelia Bartoli's paper takes up the French sociologist's theory of the State outlined during courses held at the College de France in 1989/1990 and 1990/1992. Bourdieu eschewed an intellectual fashion of his time that pushed historians, political scientists, lawyers and sociologists to examine the causes and reasons, evolutions and epilogues of revolutions, at the expense, however, of what is happening on the background: the dull, muffled and repetitive order of things. Bourdieu believed that permanence more than change, what is obvious more than what is eccentric, the ord…
EMG amplitude of the biceps femoris during jumping compared to landing movements.
2013
Abstract Hamstrings injury is a common occurrence in athletic performance. These injuries tend to occur during a deceleration or landing task suggesting the negative work may be a key component in hamstrings injury. The purpose of this study was to investigate the muscular activity (EMG) of the biceps femoris (BF) in different phases (concentric vs. eccentric) of a Counter Movement Jump (CMJ), Squat Jump (SJ) and the Braking Phase (BP) of a landing task. Twelve female volleyball players performed 5 CMJs, SJs and BPs while surface EMG was recorded using a MuscleLab (BoscoSystemTM, Norway). EMG values were normalized to an maximal voluntary contraction. A repeated measures analysis of varianc…
Responses to eccentric rotation in two space-bound subjects
1993
Two subjects were rotated eccentrically in the manner described previously. In contrast to a normal control group, settings of a luminous line to the subjective vertical were almost unrelated to the gravitoinertial vector before, and totally so shortly after, space flight. Only 3 days postflight did a clear relation to the gravitoinertial vector re-establish itself in the one subject who actually flew. The correspondence became normal 5 days after the flight. Since there were no clinical abnormalities evident in the subjects, it is suggested that both subjects suppressed their vestibular information, presumably as an effect of vestibular deconditioning training before the flight. In additio…