Search results for "efficient"
showing 10 items of 1603 documents
Prediction of arch length based on intercanine width.
2008
Arch length (AL), intercanine width (ICW), and intermolar width (IMW) are essential for diagnosis and treatment planning and are closely related factors in orthodontics. The aim of the present study was to determine correlations between these measurements and to predict some of these measurements based on others. The dental casts of 197 Spanish patients (119 females and 78 males) with a mean age of 18 years (11-26 years) in the permanent dentition attending the Orthodontic Department of the University of Valencia, Spain, were selected. ICW, IMW, and AL on each dental cast were measured using a previously tested digital method. Correlation between variables was determined using Pearson's cor…
Transient seizure onset network for localization of epileptogenic zone: effective connectivity and graph theory-based analyses of ECoG data in tempor…
2018
Objective: Abnormal and dynamic epileptogenic networks cause difficulties for clinical epileptologists in the localization of the seizure onset zone (SOZ) and the epileptogenic zone (EZ) in preoperative assessments of patients with refractory epilepsy. The aim of this study is to investigate the characteristics of time-varying effective connectivity networks in various non-seizure and seizure periods, and to propose a quantitative approach for accurate localization of SOZ and EZ. Methods: We used electrocorticogram recordings in the temporal lobe and hippocampus from seven patients with temporal lobe epilepsy to characterize the effective connectivity dynamics at a high temporal resolution …
Reliability and validity of the form 90 interview.
2004
<i>Objective:</i> Alcohol consumption is a central variable in substance abuse research and treatment. The study reports the psychometric characteristics of the German version of the Form 90 interview for the assessment of recent alcohol consumption. <i>Method:</i> Reliability was evaluated in a test-retest study (7 days) with 30 consecutively admitted psychiatric inpatients with alcohol dependence. Validity of Form 90 was assessed with a second sample of 60 alcohol-dependent inpatients. <i>Results:</i> Form 90 demonstrated good to excellent retest reliability for the central variables of alcohol consumption. Retest reliability Pearson correlation coeffic…
Intra and intersession repeatability and reliability of the S-Plate® pressure platform.
2017
Abstract Aim The aim of this study was to assess the repeatability and reliability of the S-Plate® pressure platform in a group of healthy subjects. Material and methods Forty subjects, free from physical conditions that would affect normal gait, walked along a five-meter corridor while data were recorded from the pressure platform. A total of 10 steps (five each side) were obtained as well as five static trials; the same measurements were repeated one week later. Peak and mean plantar pressures and contact area were recorded for both dynamic and static trials. Additionally, weight supported on each limb was documented during static trials. To assess intrasession and intersession repeatabil…
Noninvasive measurement of intracranial pressure: Is it possible?
2007
BACKGROUND: Some publications suggest a strong correlation between the intracranial pressure and the intraocular pressure. Other studies claim no correlation between these two physiologic variables. Our aim was to study whether the tonometry could be a useful method to evaluate intracranial pressure in patients with suspected intracranial abnormality. METHODS: We evaluated the correlation between the intracranial pressure and the intraocular pressure, the intracranial pressure and the mean arterial pressure, and the intraocular pressure and the mean arterial pressure in 22 patients, initially comatose, who were admitted to our hospital. All patients required the intracranial pressure monito…
Multislice multiecho T2* cardiac magnetic resonance for the detection of heterogeneous myocardial iron distribution in thalassaemia patients
2009
The present study investigated myocardial T2* heterogeneity in thalassaemia major (TM) patients by cardiac magnetic resonance (CMR), to determine whether is related to inhomogeneous iron overload distribution. A total of 230 TM patients consecutively referred to our laboratory were studied retrospectively. Three short-axis views (basal, medium and apical) of the left ventricle (LV) were obtained by multislice multiecho T2* CMR. T2* segmental distribution was mapped on a 16-segment LV model. The level of heterogeneity of the T2* segmental distribution, evaluated by the coefficient of variation (CoV), was compared with that of a surrogate data set, to determine whether the inhomogeneous segme…
Evaluation of the efficacy of oral deferiprone in beta-thalassemia major by multislice multiecho T2*.
2006
Objectives: Oral deferiprone (L1) appears to be promising in the treatment of beta-thalassemia major (TM) patients. T2* magnetic resonance imaging (MRI) with a single measurement in the mid-ventricular septum was validated as a quantitative evaluation of myocardial iron overload. Previous studies suggested a marked heterogeneity of iron distribution in the myocardium. We set up a multislice multiecho T2* MRI for the detection of this heterogeneity. The aim of our study was to investigate differences between the L1 vs. the subcutaneous desferrioxamine (DF)-treated patients using this new approach.Methods: Thirty-six beta-TM patients (age 29 +/- 8 yr) underwent MRI. Eighteen patients received…
Multislice multiecho T2* cardiovascular magnetic resonance for detection of the heterogeneous distribution of myocardial iron overload.
2006
Purpose To assess the tissue iron concentration of the left ventricle (LV) using a multislice, multiecho T2* MR technique and a segmental analysis. Materials and Methods T2* multiecho MRI was performed in 53 thalassemia major patients. Three short-axis views of the LV were obtained and analyzed with custom-written software. The myocardium was automatically segmented into 12 segments. The T2* value on each segment as well as the global T2* value were calculated. Cine dynamic images were also obtained to evaluate biventricular function parameters by quantitative analysis. Results For the T2* global value, the coefficient of variation (CoV) for intra-/interobserver and interstudy reproducibili…
Measurement of EMG activity with textile electrodes embedded into clothing.
2007
Novel textile electrodes that can be embedded into sports clothing to measure averaged rectified electromyography (EMG) have been developed for easy use in field tests and in clinical settings. The purpose of this study was to evaluate the validity, reliability and feasibility of this new product to measure averaged rectified EMG. The validity was tested by comparing the signals from bipolar textile electrodes (42 cm(2)) and traditional bipolar surface electrodes (1.32 cm(2)) during bilateral isometric knee extension exercise with two electrode locations (A: both electrodes located in the same place, B: traditional electrodes placed on the individual muscles according to SENIAM, n=10 person…
Functional connectivity analysis using whole brain and regional network metrics in MS patients
2016
In the present study we investigated brain network connectivity differences between patients with relapsing-remitting multiple sclerosis (RRMS) and healthy controls (HC) as derived from functional resonance magnetic imaging (fMRI) using graph theory. Resting state fMRI data of 18 RRMS patients (12 female, mean age ± SD: 42 ± 12.06 years) and 25 HC (8 female, 29.2 ± 5.38 years) were analyzed. In order to obtain information of differences in entire brain network, we focused on both, local and global network connectivity parameters. And the regional connectivity differences were assessed using regional network parameters. RRMS patients presented a significant increase of modularity in comparis…