Search results for "elasticity"
showing 10 items of 736 documents
Mechanical Characterization of Polymers on a Nanometer Scale through Nanoindentation. A Study on Pile-up and Viscoelasticity
2007
The analysis of nanoindentation force curves collected on polymers through the common Oliver and Pharr procedure does not lead to a correct evaluation of Young’s modulus. In particular, the estimated elastic modulus is several times larger than the correct one, thus compromising the possibility of a nanomechanical characterization of polymers. Pile-up or viscoelasticity is usually blamed for this failure, and a deep analysis of their influences is attempted in this work. Piling-up can be minimized by indenting on a true nanometer scale, i.e., at penetration depth smaller than 200 nm. On the other side, it is common knowledge that fast indentations minimize the effect of viscoelasticity. How…
Strain state analysis of InGaN/GaN - sources of error and optimized imaging conditions.
2006
Transmission electron microscopy investigation of the chemical composition of In x Ga 1-x N/GaN layers by strain state analysis can lead to substantial artefacts. We evaluated simulated images in dependence of specimen thickness, specimen orientation and objective lens defocus. We observed that the measurement is in agreement with the true strain profile for certain conditions only. An analysis of error sources revealed that artefacts are mainly caused by a combination of delocalization and the composition dependence of the phases of the beams contributing to the image formation. The delocalization effect is minimized for interference of the undiffracted beam with one of the 000 ± 2 beams. …
Comparison of Elastic and Rigid Registration during Magnetic Resonance Imaging/Ultrasound Fusion-Guided Prostate Biopsy: A Multi-Operator Phantom Stu…
2018
The relative value of rigid or elastic registration during magnetic resonance imaging/ultrasound fusion guided prostate biopsy has been poorly studied. We compared registration errors (the distance between a region of interest and fiducial markers) between rigid and elastic registration during fusion guided prostate biopsy using a prostate phantom model.Four gold fiducial markers visible on magnetic resonance imaging and ultrasound were placed throughout 1 phantom prostate model. The phantom underwent magnetic resonance imaging and the fiducial markers were labeled as regions of interest. An experienced user and a novice user of fusion guided prostate biopsy targeted regions of interest and…
Elasticity and yield strength of pentagonal silver nanowires: In situ bending tests
2014
This paper reports in situ mechanical characterization of silver nanowires (Ag NWs) inside a scanning electron microscope using a cantilevered beam bending technique. Measurements consisted in controlled bending of a cantilevered NW by the tip of an atomic force microscope glued to the force sensor. Relatively high degree of elasticity followed by either plastic deformation or fracture was observed in bending experiments. Experimental data were numerically fitted into the model based on the elastic beam theory and values of Young modulus and yield strength were extracted. Measurements were performed on twenty Ag NWs with diameters from 76 nm to 211 nm. Average Young modulus and yield streng…
Using ultrasound transmission velocity to analyse the mechanical properties of teeth after in vitro, in situ, and in vivo irradiation.
2000
Ultrasound transmission velocity (UTV) in isotropic material as a measure for the modulus of elasticity was correlated to mechanical properties. Changes in micromechanical properties of radiated teeth and influence of the oral cavity were to be evaluated nondestructively. UTV was measured in extracted teeth after 36 Gy and 62 Gy of in situ (enorally, with no contact to the oral cavity) and in vitro irradiation. Relative to controls, teeth subjected to 62 Gy in vivo showed higher UTV values for dentine and enamel. Sound teeth irradiated with 60 Gy in situ also showed higher UTV values for enamel, whereas dentine values were not significantly different from those of control. The mechanical pr…
The origin of in-plane stresses in axially moving orthotropic continua
2016
In this paper, we address the problem of the origin of in-plane stresses in continuous, two-dimensional high-speed webs. In the case of thin, slender webs, a typical modeling approach is the application of a stationary in-plane model, without considering the effects of the in-plane velocity field. However, for high-speed webs this approach is insufficient, because it neglects the coupling between the total material velocity and the deformation experienced by the material. By using a mixed Lagrange–Euler approach in model derivation, the solid continuum problem can be transformed into a solid continuum flow problem. Mass conservation in the flow problem, and the behaviour of free edges in th…
Competition and inflation differentials in EMU
2008
In a monetary union, inflation rate differentials may be substantial over the business cycle. This paper parameterizes a two-country monetary union in which different economic structures in the two countries generate temporary inflation differentials. Cross-country differences are introduced in (i) the elasticity of demand in the goods markets, which cause producers to discriminate prices, (ii) the degree of price inertia and (iii) the degree of openness or preference for foreign goods in consumption. The model is calibrated to reproduce two average large EMU countries and it is able to generate such inflation differentials. We find the mechanism of price discrimination quantitatively more …
Removal of Viscoelastic Substances
2000
All viscoelastics should be completely removed from the eye to reduce the likelihood of increased intraocular pressure. Should OVD retention behind the IOL occur, an unstable refraction could result. Residual high molecular viscous substance is transported away through the trabecular meshwork, with delay, possibly resulting in a protracted postoperative IOP increase. To aspirate viscoelastics various techniques as well as instruments with different aspiration/irrigation adjustments have been proposed, a few of which will be described here. Viscoelastic removal involving the simultaneous irrigation and aspiration through a single cannula (Nevyas, 1987) or two separate cannulas (Brauweiler, 1…
Bio materials with reclaimed asphalt: from lab mixes properties to non-damaged full scale monitoring and mechanical simulation
2019
Three innovative environmentally friendly pavement materials, designed with 50% of Reclaimed Asphalt and three different biomaterials (2 bio-additivated bitumens and 1 bio-binder), were produced in an industrial plant. These mixes were tested in lab and also at full scale using an Accelerated Pavement Test facility. The asphalt mix viscoelastic properties were measured in lab and their intrinsic viscoelastic response were simulated. These rheological models are used to simulate the pavement mechanical response using both elastic and viscoelastic multilayer codes. Hence, full scale measurement performed during the full scale test at an early stage (without damages) can be compared with these…
A novel boundary element formulation for anisotropic fracture mechanics
2019
Abstract A novel boundary element formulation for two-dimensional fracture mechanics is presented in this work. The formulation is based on the derivation of a supplementary boundary integral equation to be used in combination with the classic displacement boundary integral equation to solve anisotropic fracture mechanics problems via a single-region approach. The formulation is built starting from the observation that the displacement field for an anisotropic domain can be represented as the superposition of a vector field, whose components satisfy a suitably defined anisotropic Laplace equation, and the gradient of the Airy stress function. The supplementary boundary integral equation is …