Search results for "elastography"
showing 10 items of 103 documents
Comparison of transient elastography and acoustic radiation force impulse for non-invasive staging of liver fibrosis in patients with chronic hepatit…
2011
Transient elastography (TE) is adequate for a diagnosis of cirrhosis, but its accuracy for milder stages of fibrosis is much less satisfactory. The objective of this study was to compare the performance and the discordance rate of acoustic radiation force impulse (ARFI) and TE with liver biopsy in a cohort of chronic hepatitis C (CHC) patients.One hundred thirty-nine consecutive patients with CHC were enrolled in two tertiary centers, and evaluated for histological (Metavir score) and biochemical features. All patients underwent TE and ARFI.TE was unreliable in nine patients (6.5%), while in no cases (0%) were ARFI invalid measurements recorded (P=0.029). By area under receiver operating ch…
Correlation between FIB4, liver stiffness and metabolic parameters in patients with HIV and hepatitis C virus co-infection.
2010
Assessment of liver fibrosis is crucial in HIV/HCV coinfected patients, in whom metabolic disturbances are frequent. Aims of this study were to analyse the association of two non-invasive liver fibrosis evaluation methods, liver stiffness measurement and FIB4, and their correlation with metabolic parameters.This was a single centre cross-sectional study. All patients underwent biochemical and virological assessment, FIB4 score, HOMA and transient elastography.Seventy-five patients were evaluated. Liver stiffness values positively correlated with FIB4 (R = 0.62; p0.0001). By ROC curve analysis the optimal cut-off for liver stiffness to identify high FIB4 was calculated as 10.1 kPa. The area …
Noninvasive assessment of liver fibrosis in thalassaemia major patients by transient elastography (TE) - lack of interference by iron deposition.
2009
The correlation between liver stiffness, measured by transient elastography, liver fibrosis, using the histological METAVIR score, and iron overload, measured by atomic absorption spectrometry was evaluated in 56 homozygous-beta-thalassaemics. Liver stiffness increased proportionally to liver fibrosis staging (r = 0.70; P > 0.001) independently of liver iron concentration (r = 0.01; P = 0.932). The area under the receiver-operating characteristic curve for prediction of cirrhosis was 0.997 (95% confidence interval [CI]: 0.925-1.000) with cut-off of 13 kPa with 100% sensitivity (95% CI: 69.0-100.0) and 95% specificity (95% CI: 84.2-99.3). Transient elastography is a reliable non-invasive too…
Transient elastography compared to serum markers to predict liver fibrosis in a cohort of Chinese patients with chronic hepatitis B.
2015
Liver stiffness measurement (LSM) using transient elastography (FibroScan) is a useful tool to assess fibrosis in various chronic liver diseases. However, studies were mainly performed in Western countries and largely focused on chronic hepatitis C (CHC). We therefore carried out a multicenter study to validate the accuracy of LSM in the assessment of liver fibrosis in a large cohort of Chinese patients with chronic hepatitis B (CHB).We compared LSM results to histological staging and serum fibrosis markers (five direct markers, APRI and FIB-4) using Spearman correlation analysis and area under receiver operating characteristic (ROC) curves (AUROCs).Four hundred sixty-nine patients were enr…
Fibrosis staging in chronic hepatitis C: Analysis of discordance between transient elastography and liver biopsy
2009
Summary. In chronic hepatitis C, transient elastography (TE) accurately identifies cirrhosis, but its ability to assess significant fibrosis (Metavir ≥ F2) is variable. Constitutional and liver disease-related factors may influence TE and here we examined the variables associated with differences. Three hundred consecutive hepatitis C virus (HCV)-RNA positive patients had biochemical tests, TE and a biopsy performed on the same day. The Dale model was used to identify the variables associated with discordance between biopsy and elastography results. In 97 patients (34.2%), TE and histological assessment were discordant. Seventy-six of 286 (26.6%) had stage ≥F2 and TE < 7.1 kPa (false negat…
Transient elastography: A non-invasive tool for assessing liver fibrosis in HIV/HCV patients
2010
AIM: To assess the prevalence of advanced liver fibrosis (ALF) in human immunodeficiency virus (HIV), hepatitis C virus (HCV) and HIV/HCV patients using transient elastography, and to identify factors associated with ALF. METHODS: Between September 2008 and October 2009, 71 HIV mono-infected, 57 HIV/HCV co-infected and 53 HCV mono-infected patients on regular follow-up at our Center were enrolled in this study. Alcohol intake, the main parameters of liver function, presence of HCV-RNA, HIV-RNA, duration of highly active anti-retroviral therapy (HAART) and CD4 cell count were recorded. ALF was defined as liver stiffness (LS) ≥ 9.5 kPa. To estimate liver fibrosis (LF) a further 2 reliable bio…
Comparison of US Strain Elastography and Entero-MRI to Typify the Mesenteric and Bowel Wall Changes during Crohn’s Disease: A Pilot Study
2017
Purpose. To evaluate and compare the mesenteric and bowel wall changes during Crohn’s disease (CD) on ultrasonography (US) Strain Elastography (SE) and Enterography Magnetic Resonance Imaging (E-MRI). Methods. From July 2014 to September 2016, 35 patients with ileocolonoscopy diagnosis of CD were prospectively examined with E-MRI and in the same time with US and SE. Results. A total of 41 affected bowel segments and 35 unaffected bowel segments in 35 patients were evaluated. US-SE color-scale coding showed a blue color pattern in the fibrotic mesentery and bowel wall in 15 patients and a green color pattern in the edematous ones in 20 patients. The signal of the bowel wall and mesenteric fa…
The WHO guidelines for chronic hepatitis B fail to detect half of the patients in need of treatment in Ethiopia
2019
Background & Aims In 2015, the World Health Organization (WHO) issued guidelines for the management of chronic hepatitis B (CHB) in low- and middle-income countries, but little is known about the applicability of the WHO treatment criteria in sub-Saharan Africa. The aim of this study was to evaluate the diagnostic performance of the WHO guidelines in a large CHB cohort in Ethiopia. Methods Treatment-naive adults who attended a public CHB clinic in Addis Ababa were included in this analysis. All patients underwent a standardized evaluation at recruitment, including blood tests and transient elastography (Fibroscan®). A Fibroscan result >7.9 kPa was used to define significant fibrosis and >9.…
Validity criteria for the diagnosis of fatty liver by M probe-based controlled attenuation parameter.
2017
Background & Aims Controlled attenuation parameter (CAP) can be performed together with liver stiffness measurement (LSM) by transient elastography (TE) and is often used to diagnose fatty liver. We aimed to define the validity criteria of CAP. Methods CAP was measured by the M probe prior to liver biopsy in 754 consecutive patients with different liver diseases at three centers in Europe and Hong Kong (derivation cohort, n = 340; validation cohort, n = 414; 101 chronic hepatitis B, 154 chronic hepatitis C, 349 non-alcoholic fatty liver disease, 37 autoimmune hepatitis, 49 cholestatic liver disease, 64 others; 277 F3-4; age 52 ± 14; body mass index 27.2 ± 5.3 kg/m2). The primary outco…
Range of Normal Liver Stiffness and Factors Associated With Increased Stiffness Measurements in Apparently Healthy Individuals
2018
Background & Aims: Transient elastography (TE) is a noninvasive technique used to measure liver stiffness to estimate the severity of fibrosis. The range of liver stiffness measurements (LSMs) in healthy individuals is unclear. We performed a systematic review to determine the range of LSMs, examined by TE, in healthy individuals and individuals who are susceptible to fibrosis. Methods: We collected data from 16,082 individuals, in 26 cohorts, identified from systematic searches of Embase, Ovid MEDLINE, Cochrane Central Register of Controlled Trials, and Cochrane Database of Systematic Reviews for studies of liver stiffness measurements. Studies analyzed included apparently healthy adul…